ig <br />Q <br />00 <br />E <br />W <br />ATTIC VENTILATION CALCULATIONS - B1 <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />p <br />. <br />SQIN. of <br />SQ. IN. of <br />Ventilators <br />(See Elev ) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />0.000000 <br />0.000000 <br />Floor <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />0.0 <br />0.0 <br />(Zone 1) <br />Upper <br />9 <br />2.000000 <br />Floor <br />1533 <br />1472 <br />210 <br />736 <br />53 <br />368 <br />411.0 <br />276.0 <br />(Zone 2) <br />135.0 <br />**NOTE — <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />0 PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703,7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PI AN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />U 1� <br />0 <br />Z M <br />0 <br />o <br />Z Co <br />a <br />U) Z <br />Ln Ut <br />W <br />M p <br />�V — <br />O LIJ <br />.�ru <br />C6 U <br />W <br />m a <br />N M <br />® ~ <br />_ <br />U co <br />LY �i <br />04 <br />O O N <br />,_ Li- 00 <br />O <br />¢ O rn <br />QO <br />Lo �v <br />rnQ o <br />A I <br />N C B D C <br />� <br />N �O <br />f0 4 N <br />ZW� <br />' p c <br />� lL <br />_ c <br />LY V¢�LLo a <br />Z 0., <br />ts'D G.CO <br />_ U <br />C, <br />OF _,ca�0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LNNR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z <br />w� <br />zgmg <br />w7a'°dK <br />UE80 <br />ccX <br />Z w <br />�pwZ <br />.2 <br />a � <br />8 U N <br />j <br />/ � <br />Q <br />g u, <br />z <br />- <br />Z <br />a <br />J w <br />U <br />Ln <br />L J <br />uj <br />8 Z <br />F— O <br />OP <br />J <br />O <br />QV <br />U Q <br />N <br />U) <br />� <br />z�z� <br />r` <br />N <br />QW <br />Q <br />dcl� - <br />0 <br />Z <br />Z <br />^ <br />0 <br />air <br />W <br />of <br />Q <br />Z <br />auuzo <br />'0' <br />a <br />ulQz <br />r--I <br />re)Q <br />Z <br />� <br />�0 <br />�i o <br />0 <br />r <br />00 <br />_ <br />a z <br />a <br />cn <br />s <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO. 5ml <br />SHEET NO. <br />5.0 <br />