My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39575 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39575 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:54:23 PM
Creation date
2/19/2025 10:04:54 AM
Metadata
Fields
Template:
Building Plans
Street #
39575
Location
Dawson Chase Dr
Contractor
Lennar Home LLC
Building Plans - Permit #
20519
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />w <br />15/32" CDX <br />En <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH 0103 SECOND GUST EXPOSURE "C" WIND ZONE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />2 INCH NAIL LENGTH <br />NOTE: . FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER, IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + <br />+ + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />6'-0" <br />+ <br />6'-0" <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + + <br />+ + <br />++ <br />+++ <br />+++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.811.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 314" wood panel <br />1-1 /8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />60 2.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />FILL CELL <br />STD. 900 HOOK BOND BEAM <br />U) <br />w <br />`� STD. 90° <br />CONT. #5 <br />CONT, #5 HOOK <br />BAR <br />BAR <br />OOC <br />C� <br />#5 CONT. <br />FROM <br />::1 <br />TOHIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small 2" min. <br />2" gap <br />max. 4 max. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full Length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />"Non -stacking over squash=20 blocks and <br />require additi0 additional wall or beam below." <br />g <br />consideration. Check <br />CN <br />local building <br />�1/16' <br />code for appropriate <br />i, <br />details in One 10d box <br />areas=20 of high or-20 sinker <br />lateral load. nail each side <br />10'-0" <br />at bearing. <br />00 <br />i <br />TANK -LESS W/H <br />ti <br />Lo CORNER OF14 <br />``' HOME H C G <br />GARAGE SIDE O O O <br />5'-0" o <br />z STUB -OUT FOR 1 I -Off o o <br />GAS METER O ' 0 <br />N <br />� C.1 <br />00 • MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />00 <br />E <br />ii <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />T-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-01 <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES --� <br />DO NOT cut, notch <br />or drill flanges <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />x <br />Boise Joist Blocking <br />1 NP 3" (10ril nails at R" o-c- <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below L&13/4" <br />d bearing wall must stack over <br />ing and wall or beam below.* <br />Joist <br />n joists meet over wall, provide <br />minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />�/ Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel "Non -stacking walls <br />Od nails SECTION @ INT. BRG. WALL require additional consideration.— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />to CD <br />6A 1Y" ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE, THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS, <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION, USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Jc <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BC15000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI6004s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14 <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90se <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) ;?III III-1 1(— <br />Nail with 10-10d nails. -r= I^ <br />Install tight to top flange. SLEEVE THRU STEM ° <br />SEE PLAN FOR °• a . • . ° ° <br />FOUNDATION INFO ° d' <br />STEM FOUNDATION <br />r—GRADE _MMKIC er-� ra nur <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />RT <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />a a <br />_ -1 I d.40. <br />III_ IlA. <br />. _ �' <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />d <br />1---- SEE FND. PLN. <br />SIZE & REINF. <br />BELOW <br />GRADE PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4' 0" <br />CENETERED @ PIPE <br />PENETRATION <br />—\ <br />PVC OR SCH40 SLEEVE <br />r L P UMBING LINE <br />d <br />Ad d <br />4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d O .d • .' d • • <br />o' ° da G <br />=11u=1 ° _ <br />_I �I I=1 i l=1 <br />o d <br />T r• <br />0 <br />SEE FND. PLN. <br />SIZE & REINF. <br />ULO <br />T <br />La <br />Z M <br />_ o <br />z�z <br />Q <br />U) z <br />Ln UI' <br />Q) C <br />ty <br />C6 p <br /><O w <br />.� U <br />r- <br />m <br />W <br />N M <br />CM co <br />W co <br />ig <br />O O N <br />U <br />5 00 <br />Y <br />QiT <br />Y F::, <br />�Q <br />a Q o <br />N C B D C <br />V N O N,� N <br />Z LU �M�Z z <br />U) <br />��� 0 }4 w <br />us <br />LU <br />Q <br />3 <br />Q <br />ttZww <br />Za-°NA <br />LL <br />LU I'fi <br />`W <br />,,`F'� <br />Mfl <br />WE <br />b GCo i� <br />tb <br />00 <br />.� <br />< � O <br />• <br />°``•' F V. •• <br />t� <br />0 F E S S 0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />az <br />0 <br />�o <br />z Q <br />a <br />f <br />H <br />�Z80 <br />2 K <br />�o?z <br />Y J <br />a �10 <br />O W N <br />�� <br />FL o <br />L <br />w <br />z z <br />0 <br />Xz <br />Z� <br />0 <br />O <br />U <br />= <br />_ <br />J <br />t— <br />U <br />�W <br />�� <br />>9 <br />�oo� <br />M 00 V <br />�D.• <br />wQ.m2 <br />U 2 <br />4 <br />N <br />Ln <br />� <br />O <br />Z� Z;� <br />*k <br />N <br /><azw <br />Z <br />I\ <br />E o 0 <br />z <br />e� <br />ado <br />LJJ <br />¢u--== <br />Z.o <br />J <br />r-•I <br />u.l <br />0 F <br />0 �E <br />T-1 <br />M <br />57 <br />Q <br />Q <br />Z <br />�aZ <br />d. <br />ztu <br />�yQo <br />CIDQO <br />z <br />_Ni <br />J DI <br />•-1 <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION N0. 5al <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.