My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39575 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39575 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:54:23 PM
Creation date
2/19/2025 10:04:54 AM
Metadata
Fields
Template:
Building Plans
Street #
39575
Location
Dawson Chase Dr
Contractor
Lennar Home LLC
Building Plans - Permit #
20519
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br />c <br />d <br />m <br />ao <br />E <br />x <br />TYP @ 2 STORY <br />J <br />S6 <br />H.B,t <br />43'-0" <br />(3) 2X4 #2 SPF W/ (3)16d 1 <br />TOENAILS @ BASE 8 <br />COND. 8 <br />S6 <br />TYP @ 2 STORY <br />I I I ( I 1fG <br />3 I <br />UP 16R Cl) <br />I I 13 14 15 I 17 18 <br />o <br />00 <br />- FLOOR G.T. <br />9 <br />FAMILY ROOM <br />8'-8" FLAT CLG. <br />CARPET C° <br />_ _ <br />42" SLOPING 0 10HALF <br />(3)2X4#2SPF 11- -- M <br />W/ (3)16d 12 - <br />TOENAILS @ <br />BASE IDI <br />G 8'-8' T o <br />S3 � <br />00 <br />C144'-0" <br />FLEX <br />8'-8" FLAT CLG. <br />CARPET <br />A <br />M � <br />N <br />O Lnn, <br />-0" <br />N <br />(2) #5'S "' <br />2X6 WAL- <br />5-SH oo <br />H4 <br />- <br />r <br />O <br />12" DEEP '_ <br />U? <br />2068 B.F. <br />-_-----_---- <br />HDR AT T-4" <br />E IV T R <br />' <br />16'-4$" <br />T-8" I T-8" T-6" <br />6-0" - <br />CL . <br />S6 <br />,� - <br />FOYER <br />T76 <br />4 <br />�'TYP <br />0 <br />f <br />_ <br />@ 2 STORY <br />(3)2X4#2SPFW/ <br />(3)16d TOENAILS @ <br />BASE <br />rBASE <br />C�7 <br />E O00 <br />E DINING ROOM <br />PATIO 8'-8�A PECLG.2 <br />rig <br />OI 0OI <br />O O O <br />u- 0 t'- <br />8'-8" FLAT CLG. <br />TILE <br />I <br />_____-- <br />' <br />2) #5 S <br />- <br />0 <br />o <br />0 <br />"' <br />W.H. <br />3) 2X4 #2 SPF W/ <br />covr, <br />3)16d TOENAILS <br />o <br />2'.6" BUILDER TO PROVIDE <br />APPLIANCE PROTECTION <br />WHEN REQUIRED PER FBC <br />CAR GARAGE <br />S3 <br />S3 - -- --- <br />I D <br />i S3 <br />I <br />I <br />4'-0" <br />1'-0" <br />_ <br />N <br />I I <br />j <br />I I <br />' <br />I I <br />" <br />8'-8" FLAT CLG. <br />I <br />I <br />I I <br />I I <br />4'-0" 6'-2" 6-6" <br />4'-8" <br />20'-8" <br />I <br />I <br />I I <br />I I <br />EDGE OF SLAB 2" <br />BEYOND WALL 'IleI <br />cV <br />cc <br />I O <br />I H w <br />I <br />w <br />I p <br />I <br />I I <br />I I <br />I I <br />I I <br />o <br />`r° <br />IT <br />N <br />r <br />I <br />F] n <br />L 36 - - - - - 3e - J 3 <br />r <br />= <br />O N <br />I " <br />I <br />I <br />I I <br />I I <br />I I <br />3 <br />CH <br />-� <br />'-8' <br />F <br />T CLG. <br />1 <br />80 <br />I <br />I I <br />2 68 <br />668 <br />B.F. <br />. <br />- <br />I----24 -- 2, --- <br />2x6 WALL <br />I <br />I <br />L - - - - - - - - - - - - <br />I I <br />I I <br />REF. <br />- OPT.- <br />PANTRY <br />16" DEEP3 <br />5-SH <br />_ <br />- <br />- <br />0 <br />N <br />N <br />iv <br />J H.B.+ <br />S6 TYP @ 2 STORY <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 j <br />S.H. <br />13 <br />20 X 38 j <br />18 4 X 3711 <br />S.H. <br />14 <br />20 X 50 j <br />18 j X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 4 <br />S.H. <br />16 <br />20X72 <br />18JX714 <br />S.H. <br />11-12 <br />271/4X26 <br />26X25J <br />S.H. <br />11-13 <br />271/4X38J <br />26x37 <br />S.H. <br />11-14 <br />274X50i <br />26x50 <br />S.H. <br />11-15 <br />27aX63 <br />26X621/2 <br />S.H. <br />11-16 <br />27jX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 z X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 i <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 j X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 4 <br />S.H. <br />33 <br />54 X 38 j <br />52 4 X 37 4 <br />S.H. <br />34 <br />54 X 50 j <br />52 j X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 j X 62 J <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 112" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />�A <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />(D <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />+26.6 / -32.2 <br />�G <br />SEE SN SHEET jr,.u_1_'�jSEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />�1111111111111111" fi I i i <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 1113111 <br />1ST FLOOR LIVING AREA 1093 <br />2ND FLOOR LIVING AREA 1489 <br />LIVING TOTAL 2582 <br />GARAGE 427 <br />FRONT ENTRY 35 <br />TOTAL AREA 3044 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION J R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />0 <br />z � <br />_ o <br />CD <br />z <br />z <br />Q <br />J <br />a <br />V) 0 <br />w <br />OLU <br />1,100 <br />� <br />o0 <br />N <br />r- 8 <br />4' <br />m a r'i <br />_ <br />O O N <br />�LL00 <br />U <br />50 <br />a^ <br /><t rn <br />o <br />< d <br />8 D. <br />N C B D C <br />.-`- <br />•,�� <br />- <br />OO MOB v�i N <br />Z NgZ � z <br />U W S <br />was I- �_" C9a <br />ii. U_ <br />U <br />W <br />W ♦♦Q♦♦ <br />10z <br />0 <br />W PPC N <br />M E_� "-' <br />U)� ¢ � <br />Z I @!fit 2, <br />`� wr ecx� <br />J �� �%b <br />0 < <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />dp <br />Lu <br />�F <br />} <br />w¢0�Er <br />UZoo <br />oo�e< <br />�OzW <br />Z <br />1 <br />2 'D <br />2 <br />oU LL N <br />J <br />l L J <br />mLo <br />LU <br />zz <br />>o <br />Zz <br />aO <br />Z <br />z <br />0 <br />43, <br />LL <br />0 <br />a <br />LU <br />�£ <br />Uuj <br />o0z <br />�k <br />I- <br />O � <br />� <br />Ln <br />X P <br />O ¢ U <br />g <br />0 <br />fV <br />L,,, 1 <br />Z`z <br />N <br />a <br />d- <br />W <br />LL2 <br />Z <br />�o <br />8, <br />W <br />J <br />Lr) <br />rl <br />LJ.1 <br />W <br />Q <br />��,�� <br />dzU0 <br />" o a a <br />o 15 o <br />,-i <br />M <br />Q <br />z <br />z <br />to <br />z <br />�Zo <br />a <br />�/� <br />0 <br />Z <br />_ <br />J z <br />¢� <br />rn0 <br />,-+ <br />a <br />U) <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO. 5ol <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.