Laserfiche WebLink
LO <br />LO <br />CN <br />c <br />m <br />v <br />n <br />0 <br />a <br />J <br />CO <br />A� <br />Co <br />E <br />O <br />C0 <br />TYP @ 2 STORY <br />J <br />S6 <br />H.B. <br />(3) 2X4 #2 SPF W/ (3)16d <br />TOENAILS @ BASE <br />43'-0" <br />T <br />COND. COND. <br />I J <br />S6 <br />�r <br />I I I I ! IG I M� <br />1 <br />I I I IUP 11.6R1 <br />I I 1 1 1 1 ! I8 <br />TYP @ 2 STORY <br />o <br />3 4 5 7 <br />CO <br />FLOOR G.T. <br />9 <br />I <br />io <br />42" SLOPING o 10 <br />FAM I LY ROOM <br />HALF WALL - 11 -- M <br />00 <br />� f SPF 12 - -- <br />= <br />I O <br />r <br />8'-8" FLAT CLG. <br />W/ <br />L6 <br />FLEX <br />CARPET ° <br />TOENAILS @ <br />BASE <br />8'-8" FLAT CLG. <br />8'-8, T <br />CARPET 1= <br />qO19 <br />G -- <br />S3 co <br />Cil <br />O <br />to <br />CM <br />© <br />CV <br />ILL <br />o <br />X <br />5-SH <br />H4 ! <br />T <br />-, <br />2" DEEP <br />-_--------- -_-- <br />in <br />2068B.F. <br />---HDRATT-4' -- ENTRY <br />r <br />16'-48" <br />3'-8" I 3'-8" 3'-6" <br />6'-0" " FLAT CLG. I <br />FOYER <br />I <br />a <br />b <br />S6 <br />U' C'31 U' r <br />TYP @ 2 STORY <br />OI O OI "' <br />8'-8" FLAT CLG. <br />3068 <br />(2) #5'S <br />O O O <br />TILE <br />(3) 2X4 #2 SPF W/ <br />" "- "- <br />------ <br />(3)16d TOENAILS @ <br />W H <br />(3) 2X4 #2 SPF W/ <br />BASE <br />0 <br />(3) 2X4 #2 SPF W/ <br />CC (3)16d TOENAILS <br />N <br />ILI"' <br />(3)16d TOENAILS <br />S3 @ BASE <br />iv <br />r <br />BASE <br />O @------ <br />-- --- <br />I <br />0 <br />2'-6" BUILDER TO PROVIDE <br />I D I <br />S3 <br />00 <br />i <br />APPLIANCE PROTECTION <br />O <br />DINING ROOM <br />WHEN REQUIRED PER FBC <br />I I <br />I <br />PATIO 8`$CAPETLG. <br />2 CAR GARAGE <br />_ <br />I II <br />' <br />8'-8" FLAT CLG. <br />I I <br />I <br />4'4" 6-2" 6-6" <br />4'-8" <br />20'-8" <br />I I <br />I I <br />I <br />I <br />EDGE OF SLAB 2" <br />I 00 <br />I <br />I <br />n n <br />IL----------JI <br />BEYOND WALL <br />N <br />I 0 <br />I 11II <br />I <br />I <br />9 <br />0 <br />'S <br />a -- ----- <br />I <br />I <br />I <br />N <br />I <br />Ill <br />3-6 ---J <br />CC <br />H <br />I O� <br />I <br />I <br />L I_ <br />S3 <br />I W <br />I <br />I <br />I p <br />I <br />I <br />_ o <br />I X <br />I <br />I <br />I <br />I <br />I <br />` <br />� <br />I <br />I <br />I <br />'-8' <br />FLAT <br />C <br />G. <br />r` <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />.. <br />I <br />I <br />I <br />I <br />I <br />2 <br />68 I <br />oil <br />I <br />I <br />I <br />6166"85 <br />B.F. <br />" 1IL "- <br />2x6 WALL <br />II <br />II <br />II <br />REF. <br />24 :< <br />PAOPT. <br />L <br />0 <br />C� <br />---- --- <br />---� -- <br />D <br />N <br />iv <br />J H.B.T <br />S6 TYP @ 2 STORY <br />5'-0" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2' <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1 /4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1 /4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 7 1 /4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />" VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />" SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X251 <br />S.H. <br />13 <br />20X38j <br />18JX37j <br />S.H. <br />14 <br />20 X 50 j <br />18 J X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 J X 62 4 <br />S.H. <br />16 <br />20X72 <br />18jX71j <br />S.H. <br />32 <br />27 1/4 X 26 <br />26 X 25 j <br />S.H. <br />� 33 <br />271 /4 X 38 j <br />N/A <br />S.H. <br />434 <br />27 4 X 50 J <br />N/A <br />S.H. <br />433 <br />NIA <br />26 x 37 <br />S.H. <br />434 <br />N/A <br />26 x 50 <br />S.H. <br />435 <br />27 J X 63 <br />26 X 62 1/2 <br />S.H. <br />J 36 <br />27 j X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 # X 25 112 <br />S.H. <br />23 <br />37JX38j <br />36jX37314 <br />S.H. <br />24 <br />37 j X 50 j <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 621/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />734 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X 25 j <br />S.H. <br />33 <br />54 X 38 j <br />52 j X 37 j4 <br />S.H. <br />34 <br />54 X 501 <br />52 4 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 � X 62 � <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 4 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />+29,7 / -30.8 <br />�, <br />+29.7 / -39.2 <br />+28.3 / -30.8 <br />C�D <br />+28.3 / -36.4 <br />O <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET HC� SEE SN SHEET <br />14.E MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED"FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION I'A1" <br />1ST FLOOR LIVING AREA <br />1093 <br />2ND FLOOR LIVING AREA <br />1491 <br />LIVING TOTAL <br />2584 <br />GARAGE <br />427 <br />FRONT ENTRY <br />35 <br />TOTAL AREA <br />3046 <br />0 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />0V <br />z o <br />z8 <br />z <br />Q <br />J <br />a <br />E3 <br />0 <br />(nOn' U <br />C0 <br />a) <br />w <br />•V � <br />O w <br />v/ <br />N <br />'- <br />U <br />m <br />W E <br />t- <br />- t3 <br />N M <br />CD C'7 <br />-0N <br />S di <br />U <br />00 <br />0-, o <br />Q <br />co <br />CO0o <br />rn <br />v Qv <br />Nr ¢ ci <br />A 1 <br />B D® <br />N CH D C <br />� N <br />V O M z 00 <br />'s <br />W <br />Z M z] <br />Imm <br />E-. <br />W -m� 43 " t5 P. <br />V -SinA= i <br />a <br />4D �' <br />0) <br />ca <br />LLM W cz <br />a <br />^+���� O �� <br />• ` <br />W.F G.CJW•• ♦. <br />V✓`D� <br />Q <br />4v <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />za- <br />f <br />zda <br />�z00 <br />Z L <br />Ww <br />� J <br />L <br />J <br />Orou.N <br />� o <br />cr_ <br />z z <br />>o <br />a <br />O <br />cal <br />O <br />iE <br />UL <br />57 <br />O <br />J W <br />Q <br />T <br />o00 <br />J <br />.n <br />{d /8� <br />u, <br />z ¢ ZZ Q <br />N <br />Q <br />QaW <br />Q <br />Z <br />z <br />r-1 <br />Ef° <br />d o !i <br />W <br />Ln <br />is " o <br />Q <br /><t <br />z <br />8~1 <br />0 z <br />c� <br />00 <br />Z <br />�Zo <br />00 <br />Ln <br />00 <br />Z <br />� <br />_ <br />`^ � <br />rn <br />,1 <br />0- <br />1 to I <br />in <br />SCALE : AS NOTED <br />DATE : 3/29/2018 <br />TECH: MJAM ES <br />VERSION N0. 5ol <br />SHEET NO. <br />1.0 <br />'Zr <br />