My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39610 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39610 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:55:18 PM
Creation date
2/19/2025 10:05:54 AM
Metadata
Fields
Template:
Building Plans
Street #
39610
Location
Dawson Chase Dr
Contractor
Lennar Homes
Building Plans - Permit #
21716
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rn <br />Q <br />rn <br />L <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A <br />INDOOR PANEL <br />CENTER <br />10 p14 copper to lights & outlets <br />00 AMP 1 <br />200 A <br />#12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />1111 a10-3 copper to Dryer <br />METER <br />MAOIN <br />2/0 or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED — <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />---------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13, All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�'4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />#PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />WP DISC. <br />GFI H. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn DCD omcrlc <br />Q EXHAUST FAN \ RUUGH-IN FOR \ 16, <br />I ^' <br />OPT. CLG. FAN/ GFI <br />(Q� EXHAUST FAN/LIGHT COMBINATION \ LIGHT PRE -WIRE \ _ GAF <br />12 ®D ELECTRIC DOOR OPERATOR (OPTIONAL) I GFI <br />CH CHIMES (OPTIONAL) 2 CAR GARAGE <br />G J <br />I <br />PUSH BUTTON SWITCH (OPTIONAL) OWNER'S SUITE - O - W I.C. <br />I <br />I <br />PUSH BUTTON SWITCH - DOOR BELL - <br />I <br />—_ I <br />SD SMOKE DETECTOR � II I� 0 <br />CO CARBON MONOXIDE DETECTOR VERIFY LOCATION <br />I <br />GFI ----- -----J ELECTRICAL PANEL <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />K TELEPHONE (OPTIONAL) <br />RECEPT. <br />USB TELEPHONE/USB (OPTIONAL) FOR ALARM VERIFY METER <br />SYSTEM LOCATION WITH <br />© TELEVISION (OPTIONAL) BUILDER <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />0 THERMOSTAT <br />ELECTRIC METER <br />mpg ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />r- <br />CD V <br />Z co <br />_ o <br />Z �O <br />Z <br />Q <br />r1 <br />L/1 <br />n <br />W <br />cn <br />4-J w <br />Mo <br />�V <br />O w <br />c <br />_ <br />C) <br />o 0 <br />m N <br />w Q <br />N M <br />10 CO <br />N -0 <br />= <br />O o`', <br />0 <br />U 'A" <br />o°D0 <br />C o <br />Q of <br />in Q o <br />rn 8- : <br />o� Q o <br />BID. <br />, e� a ` <br />•JI P <br />e� IIIA O h N <br />V ch rn <br />Z <br />Z W z � z° <br />U) <br />a "�o m <br />i <br />W M w <br />aj C i�. o y <br />W V <br />10 <br />0 a <br />a <br />% <br />N.ca$� m m <br />o� . <br />LL`" <br />N¢r e o <br />W <br />O C) v O <br />WWW'.FDSENG.COM Ii Li <br />rn <br />0 <br />fV <br />00 <br />CV <br />Co <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />IS <br />0 <br />in <br />cc <br />za <br />z <br />uz6O <br />U <br />Z W <br />$� <br />0 <br />�owZ <br />J <br />0 J <br />Quu <br />U' LL N <br />L <br />< <br />LL <br />ZO <br />Lim <br />f <br />zCZL <br />w <br />Z <br />�/ <br />J <br />4 $ <br />T� <br />w <br />O <br />J W <br />0.) <br />T� <br />O <br />o O o <br />0 <br />L— <br />z <br />.0, U <br />N< <br />J <br />Z a <br />C <br />QZo <br />QC <br />FR Q _0 <br />FO <br />Z <br />S O <br />tL <br />—I <br />LI <br />T--I <br />di <br />lJJ <br />a <br />W U <br />a Z ou <br />~�a <br />g~o <br />`z <br />00 <br />Z <br />a <br />0S <br />coM <br />-r <br />a <br />O <br />g <br />,--I <br />a <br />LO <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAM ES <br />VERSION N0. 4nO <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.