My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39615 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39615 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:59:44 PM
Creation date
2/19/2025 10:06:07 AM
Metadata
Fields
Template:
Building Plans
Street #
39615
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20405
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 � � ( 5— Do—�, 6`K, <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN <br />7 <br />ROOF FRAMING PLAN <br />8 <br />LINTEL DETAILS <br />SN <br />STRUCTURAL NOTES <br />ABBREVIATIONS <br />SN1 <br />DETAILS <br />AB or A.B. Anchor Bolt <br />FIX or FXD Fixed <br />RA or R/A or R.A. Return Air <br />S3 <br />DETAILS <br />S4 <br />DETAILS <br />ABV or Abv. Above <br />FLR or Fir. Floor <br />RAG or Rag. Return Air Grill <br />AC or A/C Air -Conditioner <br />FLR SYS or Fir Sys Floor System <br />RAD or Rad. <br />Radius <br />ADJ or ADJ. Adjustable <br />FOM or F.O.M. Face Of Masonry <br />REC or Rec. <br />Recessed <br />S5 <br />DETAILS <br />AFF or A.F.F. Above Finished Floor <br />FP or F.P. Fireplace <br />RECEPT <br />Receptacle <br />SS <br />RETROFIT DETAILS <br />AHU or A.H.U. Air Handler Unit <br />FR DR French Door <br />REF or Ref. <br />Refrigerator <br />ALTorALT, Alternate <br />FRT Front <br />REINF <br />Reinforcing <br />D1 <br />SECTIONS & DETAILS <br />Be Base Cabinet <br />FT or Ft. Foot/ Feet <br />REQD or Req'd. <br />Required <br />WP <br />WATERPROOFING DETAILS <br />BF B'tfold Door <br />FTG or Ftg. Footing <br />RM or Rm. <br />Room <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />BK SH or Bk Sh BookSheif <br />GALV or Galv. Galvanized <br />RND or Rnd. Round <br />BLK or BILK. Block <br />GC or G.C. General Contractor <br />RO or R.O. <br />Rough Opening <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />BLW or BLW. Below <br />GFI or G.F.I. Ground Fault Interrupter <br />RS or R/S or R&S <br />Rod and Shelf <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />BM or Bm. Beam <br />GT or G.T. Girder Truss <br />SD or SD. Smoke Detector <br />BOT or Bot. Bottom <br />GYP BD or Gyp. Bd. Gypsum Board <br />SQ FT or SF or S.F. <br />Square Foot (feet) <br />BP or B.P. Bypass (door) <br />HB Hose Bibb <br />SGD <br />Sliding Glass Door <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />BRG or BRG. Bearing <br />HDR or Hdr. Header <br />SH or Sh. <br />Shelves <br />C Carpet <br />HGT or Hgt. Height <br />SHWR or Shwr. <br />Shower <br />CAB Cabinet <br />HH or H.H. Hand Held (plumbing faucet) <br />SHT Sheet <br />CIR or Cir. Circle <br />HORIZ Horizontal <br />St. or S.L. <br />Side Lights <br />CJ or C/J Control Joint <br />HS Hard Surface (flooring) <br />SPF or S.P.F. <br />Spruce Pine Fir <br />CLG or Cig. Ceiling <br />ILO In Lieu Of <br />SPECS or SPECS. Specifications <br />CMU Concrete Masonry Unit <br />INSUL or Insul. Insulation <br />SQ or Sq. <br />Square <br />COFF or Coff. Coffered or Tray Ceiling <br />INT or Int. Interior <br />STO <br />Storage <br />COL or Col. Column <br />KIWALL or KIWall Kneewall <br />SW or S.W. Shear Wall <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />KS or K.S. Knee Space <br />LALauri. Laundry <br />SYP or S.Y.P. <br />TB <br />Southern Yellow Pine <br />Towel Bar <br />❑ <br />CONN or CONN. Connection <br />or Lay. Lavatory <br />LAV or <br />TEMP or Temp. <br />Tempered <br />CT or C.T. Ceramic Tile <br />LF or L.F. Linear <br />THIKN o <br />Thicken <br />'EIDE] <br />D or D. Dryer <br />LL Lintel Length <br />TOB or T.O.B.O.BTop of Block <br />0 FE 11 F71 Ll <br />DB Door Bell <br />LT Laundry Tub <br />TOM or T.O.M. <br />Top of Masonry <br />DBL or Dbl. Double <br />MAT Management (room) <br />TOP or T.O.P. <br />Top of Plate <br />DCF Decorative Cemenfitious Finish <br />MAS or Mas. Masonry <br />TP Toilet Paper Holder <br />DEC or Dec. Decorative <br />MAX or Max Maximum <br />TR <br />Towel Ring <br />DED or Ded. Dedicated (outlet) <br />MC Medicine Cabinet <br />TRANS WDW or Trans. <br />Transom Window <br />EA E MFDD 1:11F71FE11 <br />DIA or Dia. Diameter <br />MFR or Mfr. Manufacturer <br />TYP or Typ. Typical1 <br />I <br />DISP or Disp. Disposal <br />MW or MICRO or Micro. Microwave <br />UC or u.c. <br />Under Counter <br />3 <br />DIST or Dist. Distance <br />MIN or Min Minimum <br />UCL Under Cabinet Lighting <br />DMF Decorative Masonry Finish <br />MIR or Mir. Mirror <br />UNO or U.N.O. <br />Unless Noted Otherwise <br />DS or D.S. Drawer Stack <br />ML or M.L. Microlam <br />V or v. <br />Valve (shower or tub/shower) <br />DTL Detail <br />MONO or Mono Monolithic <br />VB Vanity Base <br />DV or D.V. Dryer Vent <br />NTS or N.T.S. Not to Scale <br />VERT or Vert. <br />Vertical <br />oOVP <br />or D.V.P. Diverter Valve (plumbing) <br />OE or O.E. Owner's Entry <br />VL or V.L. <br />Versalam <br />DW or D.W. Dishwasher <br />OPNG or Opn'g. Opening <br />VTR Vent through Roof <br />EA or Ea. Each <br />OPT or Opt. Optional <br />W or w <br />Washer <br />EW or E.W. Each Way <br />PC Pull Chain <br />W/ or w/ <br />With <br />ELEC or Elec. Electrical <br />PIED or Ped. Pedestal <br />WC or W/C or W.C. <br />Water Closet (toilet) <br />oNo <br />ELEV or Elev. Elevation <br />PH Phone <br />WA or W.A. Wedge <br />Anchor <br />'n <br />EQ Equal <br />PKT or Pkt. Pocket (Door) <br />WD or Wd <br />Wood <br />EXT or Ext. Exterior <br />PL or P.L. Parallam <br />WDW HDR or WDW. HDR. <br />Window Header <br />EXP or Exp. Expansion <br />PLF Pounds per linear foot <br />WH or W. H. <br />Water Heater <br />FBC Florida Building Code <br />PLT HT or Pit. Ht, Plate Height <br />WIC or W.I.C. Walk-in Closet <br />FDN or Fdn. Foundation <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />rn <br />FXD GL Fixed Glass <br />PSF Pounds per square foot <br />WP <br />Water Proofing) <br />FG Fiberglass (Shower Pan) <br />PT or P.T. Pressure Treated <br />WS Water Softener <br />FIN Finished <br />PW or P.W. Pre -wire <br />WWF <br />Welded Wire Fabric (Mesh) <br />2 <br />FIN FLR or FF or Fin. Fir. Finished Floor <br />PWDR or Pwd. Powder Room <br />N <br />REVISIONS <br />0 <br />J <br />LO <br />08-20-15 1.0 <br />NEW BASE PLAN <br />I <br />00 <br />It <br />12-8-15 2.0 ADDED VAULT. CLG. <br />c <br />12-28-17 3.0 <br />2017 FBC UPDATES <br />v <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />o <br />02-21-18 4.0 <br />ADDED GRADE BEAM 150 MPH ENG. <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />°° <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />1 <br />2 <br />FOR 12 MONTHS AFTER THE DATE IT <br />eg <br />IS 51GNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />= <br />/ <br />CODES FLORIDA L UILDING CODEpREVAll11VG <br />1VATIONAL IrLECiRr MODE+ <br />Y <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />®�IiNCES "� HILLS <br />0 <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />U <br />REV11�w <br />Notice to Builder &All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />WITYQp <br />Zep _ "?� <br />Cl-'i�`�r <br />i <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />j <br />the commencement of any work. The Designer/Engineer are not <br />00 <br />responsible for any plan errors, omissions,or misinterpretations <br />N <br />undetected and not reported to the Designer / Engineer prior to <br />M <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />w <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />0 1 <br />Z ch <br />_ o <br />zC) <br />z <br />J <br />t� z <br />V) C9 <br />w <br />(DM0 <br />4—J <br />0 <br />wLn <br />'m <br />i V <br />22y co <br />o0 <br />m <br />W <br />® ~ <br />04 <br />N co <br />N CoO M <br />04 <br />Q � O <br />U <br />C2, o <br />5 <br />o 0 <br />¢ rn <br />LO <br />41 <br />rn¢ ci <br />AlI <br />BID. <br />N _ <br />N� <br />=J{ <br />Cn <br />fAO M O '� ONO <br />Z W Mzgz H, z <br />M <br />� a <br />LUdi yam. a w <br />m <br />,o. <br />a <br />-gW LL <br />Ck =, FA.; <br />Z 0 (i) C <br />"S < <br />Z ono !mom <br />N w <br />�� <br />�a�ILL 1 <br />�p W N o o <br />1 A <br />v`• �w sEtCGtro <br />'\Cl <br />I` ES <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L E N NAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />�o <br />W <br />Za <br />W¢0�� <br />oo <br />Z ,u <br />.5Z <br />00 <br />a� <br />� 0. <br />/ \ <br />� <br />W <br />O <br />{ lJ N <br />Co <br />LU <br />Z 7 <br />^� <br />{i <br />= <br />Z Z <br />� <br />CZL <br />t.0 <br />iE <br />57 <br />r., <br />> <br />0 <br />J < <br />UUJ <br />= <br />�oloo <br />to <br />A <br />W< <br />Z <br />2 <br />@ <br />J <br />r1 <br />W <br />z <br />LL] <br />� <br />Z <br />9 z o <br />$�o <br />Z <br />000 <br />90 <br />� <br />g <br />LU <br />z <br /><Q <br />o <br />SCALE : AS NOTED <br />DATE : 3/15/2018 <br />TECH: MJAMES <br />VERSION NO. 4n0 <br />SHEET NO. <br />C S <br />
The URL can be used to link to this page
Your browser does not support the video tag.