Laserfiche WebLink
r <br />a <br />00 <br />- <br />rune — <br />1'-0" <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />12 <br />5� <br />15'-0" RIDGE VENT <br />12 <br />�5 <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED - <br />ON DOOR <br />14'-0" RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------------------ <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />�5 <br />REAR ELEVATION - Al <br />T.O.M. --- - - -- <br />HDR HGT. <br />-4-4, - - - - - - - - - - - - - - - - <br />-------------------------- <br />----------------------- <br />— —-------- <br />TEXTURED <br />CEMENTICIOUS TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />FINISH ON C.M.U. 2'-0" <br />(TYP.) (TYP.) <br />F.FL - <br />RIGHT ELEVATION - Al <br />SCALE: 1/4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />.G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED, LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ port►and cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1 /300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN'"' <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA/ SQ. FT. <br />7 <br />�ry <br />4 1 <br />z_o <br />z° <br />z� <br />a <br />z <br />to Ut <br />W w <br />DU <br />�_ Q <br />— <br />O W <br />� <br />T <br />o <br />�V) <br />U <br />mo0 <br />W <br />F— E <br />�M M <br />Z <br />O _ o <br />U <br />�o <br />¢Co <br />��oD <br />03fl-o <br />Lo2L71 <br />m Q d <br />E D® <br />N - <br />-Jl <br />�N�Z <br />Z W � z <br />U) 1••• o w <br />a N o. <br />Q W y `r °~ w <br />Z V a a <br />oy <br />•'/ '7'�� <br />Q <br />�\ <br />N f7 •• <br />Q' f • \S E� '°•• - <br />r SENG.0 <br />z <br />r •°, <br />/"Banliliil0\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0o <br />Wo <br />z d <br />z <br />�F <br />Wz8'0o <br />/� <br />0 <br />zo <br />Z u, <br />�-zz <br />ul <br />W <br />apu�u- <br />"�Lo <br />LU <br />z <br />LU <br />z <br />18 <br />1 <br />C)_ <br />�./ <br />C/) <br />14 <br />F3 <br />T�ILI <br />r'r <br />o <br />WwA <br />C <br />�°ce. <br />0 <br />z Ic <br />¢ogQ <br />Z <br />z <br />r-i <br />oLL0 <br />C),2 <br />J <br />di <br />Q <br />diR<z <br />2:�0< <br />z <br />$ z <br />00 <br />r-i <br />Lr) <br />z <br />z <br />a w o <br />CID <br />0 <br />00 <br />g <br />UJ <br />_ <br />uj <br />SCALE : AS NOTED <br />DATE : 3/15/2018 <br />TECH: MJAMES <br />VERSION NO. 4n0 <br />SHEET NO. <br />3.2 <br />