Laserfiche WebLink
t <br />c <br />c <br />a <br />u7 <br />x <br />rn <br />O <br />J <br />r- <br />ER <br />d' <br />2 <br />E <br />A <br />H.B. ` ) S3 TYP @ 1 STORY <br />O <br />25-SH <br />AC PAD <br />1 <br />`� 30 <br />r <br />FIBERGLASS <br />URROUND <br />jr <br />,n <br />IBERppGLAS <br />1,. <br />15'-04" <br />1l <br />URj-DEN <br />10'-4" <br />10'-5" <br />°° <br />2 <br />0 <br />r` <br />0 M <br />AN <br />0� <br />60"x36" <br />�r <br />= <br />I <br />SHOWER <br />- `O <br />= <br />U) <br />'h A <br />N <br />TILE <br />LIN <br />N <br />C <br />N <br />OWNER'S _ <br />BEDROOM 3 <br />TL <br />BEDROOM 2 <br />165DEEP <br />� <br />I <br />I <br />T <br />SUITE <br />8'-0" CLG. <br />8'-0" CLG. <br />1 <br />I 8'-0" CLG. <br />"' <br />j <br />CARPET <br />I oo <br />CARPET <br />CARPET <br />8 <br />1 <br />8' 0 2,_4. <br />4' 2,. 3. cO <br />3'-32" <br />?ds� I <br />W. I.C. 1 <br />2668 <br />2668 <br />A <br />S3 00 <br />LQ <br />.- <br />A <br />I (4) 2x4 #2 SYP STUDS <br />USP HTT4 @ BASE <br />� <br />AHU 8'-0" CLG. <br />4068 B.F. �I <br />4068 B.F. <br />TYP @ 1 STORY <br />_ R&S� <br />S3 <br />TW,1 <br />N <br />CARPET I z <br />=a w 166 <br />TYP @ 1 STORY <br />----� <br />--------- - <br />--------- (n0 z <br />-- <br />-------------- <br />5'-8' <br />o <br />10" 4'-0" I <br />R&S iV <br />R&S rnio J <br />T -_ f= - - - - <br />20 <br />N <br />8 <br />R&S <br />HT AT 7'-4" <br />G I <br />I <br />FOYER(4) 2x4 #2 SYP STUDS <br />I <br />TILE <br />I `? <br />1 `f <br />8'-62' in <br />1„ W/ USP HTT4 @ BASE <br />-10d 6'-8" 9 -6„ CLG. <br />s <br />7 -48" <br />I <br />78' <br />�Cl)16'-2" <br />CAFE I <br />K <br />3068 <br />10 <br />`n <br />O <br />E <br />VAULT. CLGI I <br />S3 <br />o <br />-' <br />,CID <br />I <br />CARPET i <br />ill D W I <br />I� I <br />o <br />_ <br />9 <br />BUILDER TO PROVIDE G.T. <br />APPLIANCE <br />Q <br />PATIO <br />I <br />III <br />I <br />CC <br />I <br />I <br />IL--J <br />I <br />N <br />W.H. <br />PROTECTION WHEN r----------- Ti <br />S3 <br />I I <br />I <br />I <br />REQUIRED PER FBC I I D <br />I <br />I <br />0 <br />M <br />4' 0" <br />2:12SLOPE <br />- <br />CEILING <br />CO <br />L <br />I ; <br />2'-6" <br />S3 <br />I <br />II' <br />II' ENTRY <br />O <br />s <br />I <br />�aQ <br />8'_0" CLG. <br />KI <br />9'-6 <br />CLG. <br />`)' <br />11� <br />I <br />I <br />K <br />S3 <br />1 I I <br />1 I I <br />I <br />I <br />I <br />I <br />N <br />I <br />C _JJ <br />2' <br />1- J 20'-04" I <br />I <br />2' <br />2„ <br />161 <br />I <br />I I <br />I C <br />II 0 <br />I o <br />I <br />I <br />I <br />Cl) <br />_ <br />06 <br />AN RY a <br />=W <br />EDGE OF SLAB 2" I Q <br />BEYOND WALL I = <br />I <br />I <br />I <br />I O <br />o <br />o <br />__ <br />I Er <br />/�------- <br />OPT. <br />�� <br />co <br />I <br />I > <br />I <br />I <br />r <br />I O <br />I <br />I <br />OM <br />/ <br />// N <br />_REF. <br />- <br />N <br />5-SH <br />16" DEEP <br />DHRU <br />2 CAR GARAGE <br />WALLT <br />I T <br />I <br />/' 1 <br />8'-0" CLG. I I <br />I <br />I <br />o <br />JIL/ <br />FAMILY R M <br />15'-02" <br />- -- - <br />HANSON BOX <br />@ 36' A.F.F. <br />I <br />20'-04" I <br />I <br />178,4 <br />1 <br />,_8., <br />o <br />/ <br />/ CARPET <br />/ <br />/ <br />I <br />W <br />(L <br />N <br />io <br />iv <br />to <br />t l <br />I <br />I <br />I <br />I <br />I <br />rr <br />/ <br />o <br />cs <br />? <br />D <br />S3 <br />I <br />I <br />I <br />I <br />I <br />I <br />N <br />N <br />- <br />0 <br />L----------- <br />1 <br />286 <br />TIE <br />2E <br />168 <br />- <br />/ <br />O <br />(V <br />A <br />S3 TYP @ 1 STORY <br />H.B. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X25i <br />S.H. <br />13 <br />20X38J <br />184X37i <br />S.H. <br />14 <br />20 X 501 <br />18 4 X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 X 62 <br />S.H. <br />16 <br />20X72 <br />18 X71 <br />S.H. <br />11-12 <br />271/4X26 <br />26X252 <br />S.H. <br />1H3 <br />271/4X38j <br />26x371 <br />S.H. <br />1 H4 <br />27 4 X 50 i <br />26 x 50 <br />S.H. <br />11-15 <br />274X63 <br />26X621/2 <br />S.H. <br />11-16 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 j X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 j <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 j X 62 1/2 <br />S.H. <br />26 <br />37 4 X 72 <br />36 j X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 � WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 j <br />S.H. <br />33 <br />54 X 38 j <br />52 j X 37 1 <br />S.H. <br />34 <br />54 X 50 j <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 i <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2.Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />DE <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />GO <br />SEE SN SHEET OH SEE SN SHEET <br />� 40 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED, THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />1ST FLOOR LIVING AREA 1555 <br />LIVING TOTAL 1555 <br />GARAGE 408 <br />FRONT ENTRY 45 <br />TOTAL AREA 2008 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION J R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />U <br />J <br />n IV <br />J� <br />C9 "' <br />zo <br />z� <br />z <br />J <br />C2 <br />C� o <br />•O w <br />o� <br />m N <br />w E <br />e U <br />cm M CT: <br />M <br />m v c•� <br />_ <br />O CO N <br />- CD <br />00 <br />iU <br />000 <br />0 Co <br />0 <br />N <br />Q rn <br />CI- <br />v 0 <br />rn Q o <br />Aj- <br />B D. <br />' <br />i <br />N N <br />m 00 <br />:i� <br />Z W R��zE�'� z <br />0 <br />LU <br />:_-WWNy.F13S <br />�A, <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENN/�R <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Oz <br />w <br />za <br />E� <br />WaWrr <br />L,Zoo <br />z U Z <br />z <br />.!-,y25z <br />c 0 � J <br />Q <br />W <br />O��o <br />u <br />OO <br />L <br />uj <br />gIn <br />U <br />�/ <br />�1 <br />O <br />Z <br />-d <br />a <br />U_ <br />O <br />C1) <br />Z <br />ZI W <br />U <br />2 <br />J <br />r <br />u <br />ri°0o <br />1- Yr- <br />o <br />�Oltn <br />2 <br />vomnmn <br />a <br />LU w <br />Q <br />Qa,� <br />Z <br />Z <br />J <br />Ln <br />LU <br />7-Z <br />W <br />¢W:5 <br />azo <br />~ate <br />$¢� <br />O <br />Z <br />to <br />Z <br />m <br />rn <br />Z <br />g <br />= <br />jrn <br />a <br />rn <br />,--I <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 5/7/2019 <br />TECH: FFLORES <br />VERSION NO. 10 <br />SHEET NO. <br />1.0 <br />4 <br />