II I 111 1 1 i <br />rn <br />a <br />rn <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY; <br />BON <br />TERMINATIOP <br />NEC 14, 250.94—/ <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />opper to lights & outlets <br />upper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />2 Alu <br />250.52 OF THE 2014 NEC. <br />----------------------------------------------� <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Dotes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />I <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />413 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />�--� <br />FLUORESCENT LIGHT FIXTURE <br />OEXHAUST FAN <br />CLCI. I f:ll.l1L rNIVCL <br />;Q EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />VERIFY METER <br />Q <br />CH CHIMES (OPTIONAL) <br />LOCATION WITHBUILDER <br />o <br />H5 PUSH BUTTON SWITCH (OPTIONAL) <br />a <br />E <br />PUSH BUTTON SWITCH - DOOR BELL <br />1.2 <br />2 <br />SD <br />SMOKE DETECTOR <br />0 <br />= <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />cn <br />TELEPHONE (OPTIONAL) <br />c� <br />o <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />0 <br />® <br />TELEVISION (OPTIONAL) <br />i <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />U <br />a <br />O <br />THERMOSTAT <br />0-ELECTRIC <br />METER <br />WWI_ <br />ELECTRIC PANEL <br />rn <br />w <br />DISCONNECT SWITCH <br />Q��� <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />-,v I <br />L � <br />C9 <br />Z o'> <br />— o <br />Z <br />Z <br />Q <br />(D t1 <br />+� Z <br />C Z <br />(1) <br />' w <br />�o <br />�V <br />O w <br />L <br />o0 <br />U <br />m N <br />W E <br />H— <br />8 <br />N M <br />c to C0 <br />N <br />O 0 <br />"s o <br />U� <br />n <br />Qo <br />CD <br />co ao <br />rn Q o <br />N �D <br />� N <br />Q� <br />M A E vt N <br />U Z W YC Z <br />P. <br />r_ ng " <br />W Q 6, � w <br />— <br />, ELL o a <br />WtV< <br />10 Z 00 -S <br />ItA @ o C m <br />y�� <br />W a �¢Mr 0 <br />UM Z <br />O c j U OO <br />WWW.FDSENG.COM <br />rn <br />0 <br />N <br />00 <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />o! o <br />W <br />zaa <br />fF <br />^Q <br />LL <br />FFao0 <br />S�Z <br />Q <br />U <br />W co <br />y_ <br />off© <br />z z <br />y0 <br />t..� <br />f z <br />LU <br />"d <br />w <br />O <br />z <br />�W <br />U <br />= <br />`.100 <br />1"� <br />O <br />o�z <br />0 <br />J <br />V— <br />Z <br />f 8 Z5 <br />VOW$ <br />c <br />c <br />az� <br />w <br />� <br />Z <br />� <br />Q�o�o <br />Z <br />0% <br />r-I <br />YR£- <br />z Er 2 �j <br />J <br />W <br />¢w, <br />F z <br />W <br />� <br />U <br />gF <br />Q <br />Q <br />Z <br />; aZ <br />�. <br />Z <br />t <br />a <br />ZS <br />0 <br />m <br />O <br />Z <br />W <br />�' z <br />w <br />a <br />V) <br />o <br />SCALE : AS <br />NOTED <br />DATE : 5/7/2019 <br />TECH: FFLORES <br />VERSION NO' 10 <br />SHEET NO. <br />4.0 <br />