Laserfiche WebLink
_T1 <br />- _ -�-� -- <br />--- <br />ElEl <br />1:1 -- <br />❑ ❑ ❑ <br />----- - <br />__ _II <br />J <br />.,_. --. <br />-- - — - <br />a a <br />ALL WORK SHALL COIAPI Y WITH PREVAILING <br />CODES FLORIDA VUILD!NG CODE, <br />NATIONAL ELECTP':".- COLIE, <br />AND THE CITY OF Z'EPHYRHILLS <br />ORDINANCES <br />AUUr i 9 <br />REVIEW DATE AA ' 46 9 <br />CITY OF zEPHYRNIL <br />PLAN EXAMINER � <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN <br />7 <br />ROOF FRAMING PLAN <br />8 <br />LINTEL DETAILS <br />SN <br />STRUCTURAL NOTES <br />ABBREVIATIONS <br />SN1 <br />DETAILS <br />S3 <br />DETAILS <br />AB or A.B. Anchor Bolt <br />ABV or Abv. Above <br />AC or A/C Air -Conditioner <br />ADJ or ADJ. Adjustable <br />AFF or A.F.F. Above Finished Floor <br />AHU or A.H.U. Air Handler Unit <br />ALTorALT, Alternate <br />BC Base Cabinet <br />BF Bifold Door <br />BK SH or Bk Sh BookShelf <br />BLK or BLK. Block <br />BLW or BLW. Below <br />BM or Bm. Beam <br />BOT or Bot. Bottom <br />BP or B.P. Bypass (door) <br />BRG or BRG. Bearing <br />C Carpet <br />CAB Cabinet <br />CIR or Cir. Circle <br />CJ or C/J Control Joint <br />CLG or Clg. Ceiling <br />CMU Concrete Masonry Unit <br />COFF or Coff. Coffered or Tray Ceiling <br />COL or Col. Column <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />CONN or CONN. Connection <br />ContCONT or Continuous <br />CT or C.T. . Ceramic Tile <br />Dryer <br />D o D. ry <br />DB Door Bell <br />DBL or Dbl. Double <br />DCF Decorative Cementitious Finish <br />DEC or Dec. Decorative <br />DED or Ded. Dedicated (outlet) <br />DIA or Dia. Diameter <br />DISP or Disp. Disposal <br />DIST or Dist. Distance <br />DMF Decorative Masonry Finish <br />DS or D.S. Drawer Stack <br />DTL Detail <br />DV or D.V. Dryer Vent <br />DVP or D.V.P. Diverter Valve (plumbing) <br />DWorD.W. Dishwasher <br />EA or Ea. Each <br />ELEC or Elec. Electrical <br />ELEV or Elev. Elevation <br />EQ Equal <br />EWorE.W. Each Way <br />EXP or Exp. Expansion <br />EXT or Ext. Exterior <br />FBC Florida Building Code <br />FDN or Fdn. Foundation <br />FG Fiberglass (Shower Pan) <br />FIN Finished <br />FIN FLR or FF or Fin. Fir. Finished Floor <br />FIX or FXD Fixed <br />FLR or Fir. Floor <br />FLR SYS or Fir Sys Floor System <br />FOM or F.O.M. Face Of Masonry <br />FP or F.P. Fireplace <br />FR DR French Door <br />FRT Front <br />FT or Ft. Footl Feet <br />FTG or Ftg. Footing <br />FXD GL Fixed Glass <br />GALV or Galy. Galvanized <br />GC or G.C. General Contractor <br />GFI or G.F.I. Ground Fault Interrupter <br />GT or G.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />HB Hose Bibb <br />HDR or Hdr. Header <br />HGT or Hgt Height <br />HH or H.H. Hand Held (plumbing faucet) <br />HORIZ Horizontal <br />HS Hard Surface (flooring) <br />ILO In Lieu Of <br />INSUL or Insul. Insulation <br />INT or Int. Interior <br />K/WALL or K/Wall Kneewall <br />KS or K.S. Knee Space <br />LAUN or Laun. Laundry <br />V Lavatory <br />LF oroL.F.y Linear Ft. <br />LL Lintel Length <br />9 <br />LT Laundry Tub <br />MAS or Mas. Masonry <br />MAX or Max Maximum <br />MC Medicine Cabinet <br />MFR or Mfr. Manufacturer <br />MGT Management (room) <br />MIN or Min Minimum <br />MIR or Mir. Mirror <br />MIL or M.L. Microlam <br />MONO or Mono Monolithic <br />MW or MICRO or Micro. Microwave <br />NTSorN.T.S. Not to Scale <br />OE or O.E. Owner's Entry <br />OPNGorOpn'g. Opening <br />OPT or Opt Optional <br />PC Pull Chain <br />PED or Ped. Pedestal <br />PH Phone <br />PKTorPkt. Pocket (Door) <br />PL or P.L. Parallam <br />PLF Pounds per linear foot <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />PLT HT or Pit. Ht, Plate Height <br />PSF Pounds per square foot <br />PT or P.T. Pressure Treated <br />PW or P.W. Pre -wire <br />PWDR or Pwd. Powder Room <br />RA or R/A or R.A. Return Air <br />RAD or Rad. Radius <br />RAG or Rag. Return Air Grill <br />REC or Rec. Recessed <br />RECEPT Receptacle <br />REF or Ref. Refrigerator <br />REINF Reinforcing <br />REQD or Req'd. Required <br />RM or Rm. Room� <br />RND or Rnd. Round <br />RO or R.O. Rough Opening <br />RS, R/S, R/SH or R&S Rod and Shelf---— <br />SD or SD. Smoke Detector <br />SGD Sliding Glass Door <br />SH or Sh. Shelves <br />SHT Sheet <br />SHWR or Shwr. Shower— <br />SL or S.L. Side Lights <br />SPECS or SPECS. Specifications <br />SPF or S.P.F. Spruce Pine Fir <br />SQ FT or SF or S.F. Square Foot (feet) <br />SO or Sq. Square <br />STO Storage <br />SW or S.W. Shear Wall <br />SYP or S.Y.P. Southern Yellow Pine <br />TB Towel Bar <br />pTempered <br />TH KN or Thik'n. Thicken <br />TOB or T.O.B. Top of Block <br />TOM or T.O.M. Top of Masonry <br />TOP or T.O.P. Top of Plate <br />TP Toilet Paper Holder <br />TR Towel Ring <br />TRANS WDW or Trans. Transom Window <br />TYP or Typ. Typical <br />UC or u.c. Under Counter <br />UCL Under Cabinet Lighting <br />UNO or U.N.O. Unless Noted Otherwise <br />V or v. Valve (shower or tub/shower) <br />VB Vanity Base <br />VERTorVert. Vertical <br />VL or V.L. Versalam <br />VTR Vent through Roof <br />W or w Washer <br />W/ or wl With <br />WA or W.A. Wedge Anchor <br />WC or WIC or W.C. Water Closet (toilet) <br />WDorWd Wood <br />WDW HDR or WDW. HDR. Window Header <br />WH or W.H. Water Heater <br />WIC or W.I.C. Walk-in Closet <br />WM or W.M. Wall Mounted (plumbing fixture) <br />WP Water Proofing) <br />WS Water Softener <br />WWF Welded Wire Fabric (Mesh) <br />S4 <br />DETAILS <br />S5 <br />DETAILS <br />SS <br />RETROFIT DETAILS <br />D1 <br />SECTIONS &DETAILS <br />WP <br />WATERPROOFING DETAILS <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />REVISIONS <br />08-20-15 1.0 <br />NEW BASE PLAN <br />ILM 17= INI <br />INI <br />JS& 11OF <br />12-8-15 2.0 ADDED VAULT. CLG. <br />12-28-17 3.0 2017 FBC UPDATES <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />1941 <br />�r^ <br />C9 <br />z <br />zto <br />z� <br />Q <br />a <br />t/) 0 <br />u, <br />�--+ W <br />o <br />•V — <br />0 W <br />La <br />�NZD <br />U <br />o0 <br />m N <br />W <br />i�'Fa <br />NMI <br />NSA <br />N M <br />fpC6� M <br />C N <br />9? <br />U <br />O O o <br />t �` o <br />oin <br />fl- o <br />rnQ d <br />MD. <br />\``M a n <br />N O <br />rn � <br />Z LU <br />Z WM z Z <br />U) <br />ED ° ❑, <br />0W V ¢ &, <br />0,�' <br />J.,Jrrat <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z <br />Z <br />Zf <br />fF <br />Zsasa <br />�zo0 <br />U U <br />nwx <br />(J Z <br />G f J <br />OD <br />W <br />O tl] � N <br />L <br />a <br />LU <br />��� <br />ZLn <br />O <br />I- <br />2 <br />U, <br />Er <br />ZU <br />i Z <br />Z <br />w <br />> <br />F <br />Z <br />0 <br />V <br />J LJ <br />�f <br />U <br />_ <br />g <br />o <br />alp <br />o <br />szm� <br />0 <br />ZUJ <br />N <br />w�a <br />Z <br />Z�� <br />J <br />LU <br />Q <br />Z <br />NZ. <br />$ a <br />Qz <br />O <br />Z <br />�ZS <br />o <br />ca <br />r <br />Z <br />W <br />- Ln <br />o <br />a-aQ <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAM ES <br />VERSION NO• 4mO <br />SHEET NO. <br />S <br />