Laserfiche WebLink
CORNER OF <br />HOME <br />GARAGE SIDE <br />O <br />rN <br />O <br />J _ <br />0 <br />rnI <br />nL <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O O O IV <br />01 5'-0" < - <br />c� <br />STUB -OUT FOR 1 _�C)0 0 <br />GAS METER O o LO <br />_ � U <br />0 O <br />N <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"*ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />1 U-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e, RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINECD <br />J 15/32" CDX <br />¢ PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH 1113 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />6'-0" <br />+ <br />6'-0" <br />++ <br />+++ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI ®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" <br />5000s 1.8/1.7 <br />wood panels <br />p nel <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 112" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />FILL CELL STD. 900 HOOK BOND BEAM <br />w <br />a STD. 90° CONT. #5 <br />BAR > HOOK F BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND �l SHEATHING PER PLAN <br />CONNECTION�r TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />-—MASONRY WALL OR <br />✓ \ INTERIOR BRG. WALL <br />\ \ TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />- Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />DOUBLE JOIST <br />CONSTRUCTION <br />(Not required if both loaded equally from above) <br />N.T.S. <br />r <br />1/8" min. 2" min. <br />) Small gap <br />Filler blocking = <br />1/8" gap <br />+ <br />2" max. max.Web <br />Stiffener e <br />} <br />-0 <br />i <br />T T- <br />Series End.Location <br />-- <br />Intermediate <br />- : <br />® 9-1/2" 2-8d <br />2-8d <br />BCI 501 11-7/8 _ 2-8d <br />3-8d <br />f <br />-- 1 4 2-8d� <br />Clinch nails <br />9-1/2 2-8d <br />2-8d <br />when <br />BCI 6000s® 11-7/8 2-8d <br />` <br />3 8d <br />possible � � <br />R <br />BCI 6500s — � II <br />16 2-8d <br />5-8d <br />6-8d <br />1) <br />Support back of web during nailing to prevent damage to <br />- - <br />j� � <br />- <br />11-7/8"� 2-8d <br />_ - -; <br />3-8d <br />web -flange connection. <br />BCI 60s 14" 2-8d <br />2) <br />Block solid between joists for full length of span. <br />Tight fit - <br />16" 2-8d <br />6-8d <br />3) <br />Leave 1/8' gap between top of filler blocking and bottom of top flange. <br />11-7/8"_ 3-16d <br />3716d _ <br />4) <br />Place joists together and nail from each side with 2 rows of 10d nails <br />Zx4/Plywood/OSB web stiffener - 2" min. <br />4" <br />BCI 90s® 1.4 5-16d <br />5-16d <br />required when indicated or max. 16" 6-16d 6-16d <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING �" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer =1900 plf max. along bearing wall <br />BEARING Use 3" (10d) nails at 6" O.C. Required on interior walls : - for vertical load transfer Plumbing <br />�! Load bearing walls when load bearing - for lateral support when joists <br />Vertical load transfer =1900 plf max along load bearing wall. i <br />Load bearing wall must stack meet over wall, or wall stacks directly over wall or <br />over squash=20 blocks and /� � � /� beam below Load bearing wall must stack over <br />*Non -stacking walls < \\ / blocking and wall or beam below.* <br />require additional wall or beam below.*��,� . i <br />consideration. Check �� -� / > Joist <br />local building ��� When joists meet over wall, provide <br />�1/16" I -Joist can be offset <br />code for appropriate 1 3/4" minimum bearing for each, <br />details in One 10d box / up to 3" to avoid <br />vertical plumbing <br />areas=20 of high or--20 sinker � �� <br />lateral load. nail each side /���� j 3" max <br />at bearing. <br />- JOISTS OFFSET <br />�N.T.S. <br />Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />Squash block) 10d nails SECTION @INT. BRG. WALL require additional consideration. <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />" `—Z ' MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />I 16" 2 " ROUND HOLE MAY 6" <br />6" <br />DO NOT CUT HOLES <br />BE CUT ANYWHERE IN <br />CANTILEVER <br />LARGER THAN 1Y2" <br />THE WEB. PROVIDE AT <br />ROUND IN <br />LEAST 3" OF CLEARANCE <br />CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN <br />Any 16 foist <br />- Span (ft)- <br />8 <br />V-0" <br />V-1 " <br />1'-2" <br />V-2" <br />V-3" <br />1 '-3" <br />V-7" <br />1'-11 " <br />2'-4" <br />2'-9" <br />3'-2" <br />3'-7- <br />12 <br />V-0" <br />V-1" <br />V-2" <br />V-2" <br />V-3" <br />V-9" <br />2'4" <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />16 <br />1'-0" <br />1'A" <br />1'-2" <br />V-2" <br />V-7" <br />2'-5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />7'-2" <br />20 <br />1'-0" <br />1'-1 " <br />V-2" <br />V-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11 " <br />6'-11 " <br />7'-11 " <br />8'-11 " <br />24 <br />V-0" <br />1'-1" <br />1'-2" <br />V-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />5'-10" <br />7' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />SIMPSC <br />w/(22)- <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22). <br />NAILS T <br />R TRUSS <br />'OP PLATE <br />ice <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) -rl I I —III —III —I — <br />�\ Nail with 1110d nails. <br />\\Install tight to top flange. a . <br />SLEEVE THRU STEM <br />Joist hanger SEE PLAN FOR �� a <br />FOUNDATION INFO e <br />STEM FOUNDATION <br />GRADE <br />Filler block. REINF. SEE PLAN <br />Nail with <br />10-10d nails. e <br />Backer block required where top ��M . 4 n� <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. a — �T <br />III-1 I C a e a Tr <br />1/4"-2" gap <br />% �Pn <br />f L� <br />f Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />-- -- requirements <br />- 0.6 X Joist <br />p depth <br />III' Y <br />I -JOISTS BUCKETS <br />N.T.S. <br />II— 0 A: — <br />i <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />'I. <br />d' <br />' <br />a <br />—TI= <br />E3 <br />GRADE <br />LL <br />- <br />cXAt I <br />Lu <br />U) <br />us <br />OT <br />INS <br />IF F <br />. <br />;X IX <br />ON � <br />4n0 <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />SEE FND. PLN. <br />SIZE &REINF. <br />PIPE VERTICAL THRU FND. <br />12" BELOW <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />/F I <br />' e ..4 <br />a e <br />� ae e - <br />e • <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />G <br />a <br />a' a ea L <br />IT I_I ICI a a° I=I I �'.I I I_ <br />O e a e <br />I <br />r <br />SEE FND. PLN. <br />SIZE & REINF. <br />I1 ;. <br />U <br />z� <br />o <br />—o <br />z� <br />z <br />Q <br />t� z <br />cn c� <br />4—J w <br />0 <br />• O w <br />C <br />� <br />C)o0 <br />m <br />w <br />— U <br />_ <br />N M <br />