Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED, LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copper to lights & outlets <br />t <br />20000 AMP <br />A <br />10 #12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />01 #10-3 copper to Dryer <br />METER <br />MAIN <br />O2/0 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED—` <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />�wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />N <br />HALF -SWITCHED DUPLEX OUTLET <br />x <br />N <br />SPECIAL PURPOSE OUTLET <br />0 <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />CID <br />a' <br />3 <br />THREE-WAY SWITCH <br />& <br />. <br />FOUR-WAY SWITCH <br />rn <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />= <br />WALL MOUNTED LIGHT FIXTURE <br />N <br />M <br />a <br />O <br />RECESSED LIGHT FIXTURE <br />J <br />a <br />PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />'46 <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />v <br />,lOt <br />EXHAUST FAN/LIGHT COMBINATION <br />c <br />o <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />Q <br />CH <br />CHIMES (OPTIONAL) <br />O <br />N <br />l� <br />PUSH BUTTON SWITCH (OPTIONAL) <br />E <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />E <br />= <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />i <br />TELEPHONE (OPTIONAL) <br />o <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />o <br />® <br />TELEVISION (OPTIONAL) <br />i <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ICII] <br />ELECTRIC METER <br />_CL <br />ELECTRIC PANEL <br />CD <br />C14J <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />N <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />0 <br />WP DISC. <br />GFI H. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />\ it 3 _ GFI ' U 7) <br />\ T RANGE <br />\ PENDANT AS <br />PER SPECS � / <br />/ U.C. S IT H <br />FOR D­1SRD8A <br />r INK I DIS <br />/0AFE \ \ I D.W. a <br />\ GFI L= <br />=GFI �- <br />c�- <br />I <br />U.C. OUTLET <br />U.C. OUTLET <br />FOR DW <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />'\\ 12 <br />IFA RM <br />I <br />I <br />'-- ` n ru <br />3S.D. \ \ <br />ROUGH -IN FOR <br />\ OPT. CLG. FAN/ \ <br />\ LIGHT PRE -WIRE \ <br />OWNER'S SUITE <br />I <br />I <br />I <br />I <br />I <br />GFI <br />I <br />— __I_ <br />OPT. I <br />REF. <br />I <br />ROUGH -IN FOR \ \ <br />OPT. CLG. FAN/ <br />GHT PRE-WIRI�; <br />BEDROOM 2\\1 <br />ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />BED�OOM 3` <br />\ 1 <br />1S <br />ME III II <br />■■rr► X.._ _.!I <br />IN"anNOWN <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />i "M iNE <br />GFI @ 44" <br />A.F.F. <br />111 <br />r------------ <br />I <br />Il I <br />11 I I <br />I <br />t <br />GFI @ 44" � I <br />A.F.F. I <br />I <br />GFI FOR I <br />GAR. DOOM <br />GFI <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />I <br />0 I <br />V.H. VERIFY LOCATION <br />ELECTRICAL PANEL IRRIGATION <br />c� ,kGF@ I 44"' A.F.F._ _ <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />/ /(�ROUGH-IN FOR <br />/ OPT. CLG. FAN/ <br />BEb R VLIGOHT PRE -WIRE <br />/ M4 <br />GFI <br />�*t---ENTRY <br />I <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Z M <br />_ a <br />z <br />Mall <br />2 <br />z <br />W to <br />+-J W <br />�o <br />O W <br />2 <br />�N <br />u <br />�r- <br />m N <br />W <br />9 <br />N C" <br />Cr M <br />m.1C%j <br />=9� <br />U `7i <br />Oo0 <br />� D- <br />co <br />¢rn <br />o°DO <br />onnno <br />to2Lv <br />� Q d <br />B D® <br />C B D C <br />�v <br />tw N N <br />v pp ZZ; <br />N <br />'� Z W ��oz � z <br />r` o r'"ai <br />Nw uj <br />W _ y�- w <br />a Y <br />�W V>C"LLo �a <br />ZC62L z <br />c 2 ¢ p <br />Z Vi € cP <br />�E_(p Q m � <br />Z <br />LLW a N¢M;E! O <br />o C-, v o0 <br />WWW.FDSENG.COM Li Li <br />rn <br />0 <br />CV <br />zo— <br />CV <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0Z <br />171 <br />�o <br />faF <br />Z <br />W Q C d <br />�zU0 <br />^ <br />Zw¢Q <br />J <br />w <br />w <br />Qo� <br />U <br />u�l1,I LL N <br />m ZZZC <br />W <br />W <br />f z <br />Z <br />J <br />W <br />0 <br />-a <br />� <br />O <br />T <br />O <br />ILL <br />o�z <br />OO <br />Z <br />u8 9: <br />a <br />Q <br />Z Z <br />0 <br />Z <br />Z <br />0*1 <br />,-I <br />0' 2 <br />3 0 i <br />W <br />J <br />Inaj <br />T__I <br />LU <br />C z 8 <br />to i2 Q <br />g�� <br />O <br />Q <br />Z <br />uj <br />W�Z <br />Un <br />dog <br />0 <br />Qz <br />J <br />= <br />`� <br />d <br />Un <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAM ES <br />VERSION NO. 4nO <br />SHEET NO. <br />4.0 <br />