Laserfiche WebLink
_ I_ ' 14 1 I 11 11 t q 11 -- - I I - -- 11 _ 1! <br />m <br />ELECTRICAL SPECIFICATION 200A INDOOR PANEL <br />CENTER <br />NOTES: <br />10 g14 copper to lights & outlets <br />NEMA 1 g 12 copper to 20 amp ckts <br />ELECTRICAL CONTRACTOR Zee AMP 10 <br />g 10-2 copper to WH <br />MUST VERIFY WITH THE 10 g 10.3 copper to Dryer <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES. MAIN <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp IT <br />I <br />I <br />POWER CO. FEED <br />I <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />j <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FqF <br />DUPLEX OUTLET ABOVE COUNTER <br />�@wP <br />WEATHERPROOF DUPLEX OUTLET <br />0GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />k& <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4 � <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />o <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />a <br />CH <br />CHIMES (OPTIONAL) <br />N <br />l� <br />PUSH BUTTON SWITCH (OPTIONAL) <br />a <br />E <br />PUSH BUTTON SWITCH - DOOR BELL <br />t° <br />SD <br />SMOKE DETECTOR <br />E <br />= <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />LZ <br />o <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />E <br />1 <br />® <br />TELEVISION (OPTIONAL) <br />U <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />U <br />N <br />T <br />O <br />THERMOSTAT <br />a <br />I <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />rn <br />85 <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />l� J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FC� ---- <br />I I <br />L _ <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />nn,n <br />Z M <br />— o <br />Z <br />Z <br />Q <br />t1 <br />C!) U <br />W � <br />a..� w <br />�o <br />Ow <br />can <br />ra U <br />o 0 <br />m N <br />w <br />r— <br />NMcn <br />C N <br />`L <br />00 <br />0 v <br />N <br />0 <br />N •O <br />co N <br />M m 00 <br />z W <br />U)Lu <br />N M <br />�/ <br />u' O � � <br />CLUWvece, a <br />a t <br />Z-ocno't <br />t7 U) o LZ <br />L m <br />UMZ .4 MM <br />W A4 A <br />O ` U O <br />WWW.FDSENG.COM O El <br />0 <br />N <br />00 <br />(V <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />�o <br />�o <br />za <br />f� <br />Z <br />Lu <br />zoo <br />Zw� <br />�oZZ <br />J <br />Lu <br />0. <br />Q.2'o <br />m <br />""'© <br />L <br />_U <br />�• <br />tLIL <br />gN <br />O <br />i 2 <br />W <br />tY <br />�1 <br />�o <br />a <br />W <br />O <br />U <br />O <br />J <br />80o <br />toYP <br />o <br />V— <br />Z <br />�5 <br />d <br />w 0 W CL <br />� C <br />N <br />¢ <br />Z<z;� <br />Z <br />'""I <br />Lr) <br />LU <br />8, <br />J <br />LJJ <br />Q <br />W <br />2:~ <br />Z <br />¢ z <br />¢ H <br />$Z <br />rl <br />10 <br />Z <br />< Z8 <br />Cal <br />Z <br />= <br />J <br />¢Z <br />a <br />U0 <br />o <br />SCALE : AS NOTED <br />DATE : 4/12/2019 <br />TECH: JBERCHAL <br />VERSION NO. 5ol <br />SHEET NO. <br />4.1 <br />