rn <br />EI <br />E <br />0 <br />_ <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />No #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O <br />or <br />4/0 SER Alu <br />200 amp <br />1-2/0 <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4GROUNDINGWIRE <br />TERMINATION PER <br />WITH CODE APPROVE <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FF <br />WEATHERPROOF DUPLEX OUTLET <br />}�wP <br />I `GFI GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />+PC LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />,Qt EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />Pe PUSH BUTTON SWITCH (OPTIONAL) <br />�D PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CO CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J OPT. CEILING FAN <br />GD (1) PHONE LINE, (1) DATA PORT <br />©W <br />OPT. <br />FAM I LY F�M GF _ ° _ <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ ` <br />LIGHT PRE -WIRE GFI <br />----- — <br />4 <br />OPT. <br />REF. J <br />I <br />I <br />I <br />GFI <br />U.C. SWITCH — -i <br />j FOR DISPOSAL KIT <br />I II <br />I II <br />I II 0. <br />IGFI z <br />&9 I � <br />PATIO III <br />I I <br />CAFE <br />GFI <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />j HOOD PER SPECS <br />°0 <br />LO I <br />GFI I <br />DISC. 4 <br />WP <br />GFI <br />AC PAD <br />H.B. <br />W <br />—_ — <br />• ppV4 <br />ama— <br />SUITE•- <br />•-LIGHT PRE -WIRE <br />■\�ad���� <br />�� a®■ l�' <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />VERIFY LOCATION <br />" IRRIGATION <br />ELECTRICAL PANEL <br />I GFI @ 44" A.F.F. _ <br />I <br />I <br />I <br />I <br />I <br />�\ <br />2 CAR <br />GARAGE <br />2 <br />I <br />C7 <br />I GARAGE <br />U44'@ <br />J v <br />LLJ LU <br />C7 <br />1 DOOR <br />QQ <br />GFI <br />A.F.F. <br />Q w <br />�I <br />I <br />I <br />I I <br />I <br />I <br />u� <br />L. — — J <br />I <br />0 <br />GFI @44" <br />I <br />L---_-------- <br />A.F.F. <br />NTRY <br />•FOYER- <br />db <br />ANN— <br />■n %����t���������������1 <br />II II 11• �u II II <br />i • • <br />-• FOR <br />BEDROOM 2 <br />LIGHT PRE -WIRE <br />-'j -• FOR <br />Li41 Ili��W OPT. CLG. FAN/ <br />LIGHT PRE-WIRI <br />INN <br />MAIN FLOOR ELECTRICAL PLAN <br />0 <br />lJ 'l <br />�7' M <br />0 <br />o <br />Z CO <br />Z <br />B <br />d <br />V) 0 <br />n <br />W <br />Crs <br />4--JW <br />�o <br />�V — <br />O "' <br />=D <br />Em <br />o <br />U <br />o <br />CO CV <br />Uj r E <br />C (9 M <br />— U <br />= 4? <br />j <br />t` O M <br />O O N <br />L 11- 00 <br />o <br />Q rn <br />") a o <br />LC) �vv <br />rn ¢ d <br />All <br />B D® <br />N C B D C <br />N �D <br />v �/� Oo M oNO <br />CII O O <br />Z NaZ <br />W oD <br />Clio? <br />C a <br />I.. �' <br />in Il o o w w <br />W N a w <br />W V-S o a <br />z o =m10 <br />��¢ o <br />ZO <br />LLSW <br />a N¢M Q <br />C) <br />O v U O <br />❑ ID <br />WWW,FDSENG.COM <br />rn <br />0 <br />CV <br />Cto <br />CV <br />CIO <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />Oz <br />L <br />w <br />Za <br />�F <br />Z <br />way <br />zo0° <br />Q <br />�LLJ <br />oWZ <br />e---N <br />J <br />apm <br />< <br />Q <br />a r <br />�w <br />U <br />m o <br />Zo <br />U <br />s <br />LU <br />T'� <br />J <br />LU <br />Lr)cr <br />0 <br />Z <br />Ja <br />U <br />= <br />0 <br />�w <br />ul9 <br />0 <br />U- <br />¢�5 <br />E <br />J <br />Z <br />wk.ma <br />oL <br />Z 4 Z <br />�Yu, <br />w Q <br />Q <br />Z <br />ON <br />Pogo <br />Z <br />it ce <br />LU <br />Lr) <br />t1i <br />' t� z b8 <br />_j <br />r-1 <br />Lu <br />X <br />00 F v <br />a <br />M <br />Q <br />z <br /><I w o <br />az <br />z <br />ce z <br />ao <br />m <br />Z <br />J <br />� <br />= <br />a <br />,-i <br />a <br />U0 <br />o <br />SCALE : AS NOTED <br />DATE : 11 /2/2018 <br />TECH: FFLORES <br />VERSION NO- 3ol <br />SHEET NO. <br />4.0 <br />uo I -- rn— T _F__ FM a 1,1 i : 1 17—,, r� - <br />�l <br />I OT <br />