My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39922 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39922 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:39:53 PM
Creation date
2/19/2025 10:07:51 AM
Metadata
Fields
Template:
Building Plans
Street #
39922
Location
Dawson Chase Dr
Contractor
Lennar Homes
Building Plans - Permit #
21907
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />C <br />v <br />0 <br />0 <br />0 <br />h <br />M <br />00 <br />Ln <br />I <br />x <br />m <br />rn <br />p <br />co <br />S <br />M <br />I <br />rn <br />aa) <br />v <br />HE <br />i <br />3 <br />Q <br />O <br />i <br />a <br />it <br />0 <br />0 <br />C <br />J <br />y <br />N <br />0 <br />U <br />O <br />a: <br />0 <br />a <br />U <br />J <br />t <br />N <br />M <br />0 <br />0 <br />5 <br />d <br />rn <br />0 <br />0 <br />w <br />0 <br />0 <br />N <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />J <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />w <br />15/32" CDX <br />J <br />a <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH <br />0103 SECOND GUST EXPOSURE "C" WIND ZONE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />6'-0" <br />+ <br />6'-0" <br />+++ <br />+++ <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />++ <br />+++ <br />+++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8' <br />5000s 1.811.7 <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) ° <br />Filler blocking # <br />1/8" gap ° <br />FILL CELL <br />w <br />X <br />STD.90° <br />CONT. #5 HOOK <br />BAR <br />STD. 900 HOOK r BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />INTERIOR/EXT WALL SEE <br />SIMPSON MGT IL <br />w/ (22)10d <br />NAILS TYP. GIRDER TRUSS <br />- CONT. #5 <br />BAR 2X TOP PLATE <br />5/8" Q <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION � <br />TO HIGHEST <br />BOND BEAM <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" <br />max. � 4 max. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />g required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGY" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Under <br />cuts. N.T.S. <br />-Under 2nd floor column w/ Inaris <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non stacking walls over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate 1/16 <br />details in One 10d box <br />areas=20 of high or--20 sinker <br />lateral load. nail each side <br />10'-0" at bearing. <br />TANK -LESS W/H ill <br />H C G <br />000 IF <br />U) <br />5'-0" <br />STUB -OUT FOR 1'-0" 0 9 0 <br />GAS METER 0 o <br />� U <br />o <br />N 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"*ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY"" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2 X 12 @ 16 O.C. <br />19-3 <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer 01 <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series De th End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8. <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />LC <br />SIMPSC <br />w/(22)' <br />NAILS T <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />�1 3/4" minimum bearing for each. I -Joist can be offset <br />�/ Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />Squash block) —10d nails SECTION INT. BRG. WALL require additional consideration.- <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) p <br />(see table below) <br />DO NOT cut, notchT; <br />or drill flanges <br />` ��- <br />79 <br />6,� A 1 2° ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. III I <br />Install tight to top flange. SLEEVE THRU STEM d <br />�. <br />/1 I�\ SEE PLAN FOR °• a . • <br />FOUNDATION INFO 4 4 <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />(7 <br />0.6 X Joist <br />depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />• .a <br />REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />q a <br />a <br />PVC OR SCH40 SLEEVE <br />�—PLUMBING LINE <br />.d <br />A <br />• c'a : a <br />CD <br />A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'4' PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATIONFl- <br />4PLUMBING LINE <br />.a <br />d ° °a. A na G <br />-III —1 a s G o .. Q �I 1 I I I- <br />'' I —III— a <br />T_III�, . Ill�lll� <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />79 <br />6,� A 1 2° ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. III I <br />Install tight to top flange. SLEEVE THRU STEM d <br />�. <br />/1 I�\ SEE PLAN FOR °• a . • <br />FOUNDATION INFO 4 4 <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />(7 <br />0.6 X Joist <br />depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />• .a <br />REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />q a <br />a <br />PVC OR SCH40 SLEEVE <br />�—PLUMBING LINE <br />.d <br />A <br />• c'a : a <br />CD <br />A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'4' PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATIONFl- <br />4PLUMBING LINE <br />.a <br />d ° °a. A na G <br />-III —1 a s G o .. Q �I 1 I I I- <br />'' I —III— a <br />T_III�, . Ill�lll� <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />M N <br />M <br />V <br />pp <br />z N O <br />z C, <br />M <br />o <br />JU) <br />a <br />l� <br />_ <br />'V'Jll � <br />jr <br />T Cn Y <br />F w g <br />FJ a Q <br />r— <br />N r~ E <br />o <br />�N = 2 <br />E <br />0 8 <br />= W, <br />= <br />U 'o 5� <br />c U) <br />0 <br />° <br />®0 <br />Q q <br />sm <br />N N <br />v�i N <br />O M O� <br />U)2 O N 2 w z <br />Z <br />U) <br />W �M�z <br />1j, <br />N <br />&Z <br />05 W <br />Z, <br />*P <br />W..,aN� �`L�•• .off <br />1-1 <br />t"" <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />o <br />C.0 <br />M <br />J <br />w2 <br />w <br />Z <br />U_ <br />E <br />cd-ca. <br />zo <br />-0 <br />» <br /><k <br />z® <br />E <br />ca I— 6 <br />0.�< <br />aZ� <br />KO <br />❑a <br />W. <br />0O <br />0 <br />0� <br />N <br /><O <br />ww <br />W C <br />v <br />, <br />O <br />maw <br />O <br />Z� <br />� <br />Non <br />W <br />a <br />¢� <br />o <br />Sao <br />5°_ <br />a <br />U <br />1k <br />o <br />_ <br />w <br />�O <br />>M <br />a <br />.J <br />co <br />M <br />003 <br />2 <br />C)0 <br />nL1 <br />W <br />/`J > <br />CD <br />. — L <br />0 <br />O <br />0 <br />Q <br />CIO <br />C <br />N <br />I_ <br />10 <br />m o <br />C: <br />Tco <br />M <br />T_Y <br />T— <br />, <br />T <br />CN C <br />r <br />ai <br />m <br />CM N <br />r- <br />a <br />z <br />z <br />ei <br />E Q ur <br />E B <br />`m <br />r_ <br />a <br />U Q p <br />JOB <br />NO : 19-5893 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />s <br />ti <br />
The URL can be used to link to this page
Your browser does not support the video tag.