Laserfiche WebLink
Sri <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NOT USED <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />1 Ll1V1 IIIYV 1 LfRVI IIIYV <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />E <br />AM <br />SELF -ADHERED FLASHING <br />1 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />8 (SEE DETAIL WP07) <br />Q <br />SELF-ADHER <br />0 <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />Z <br />1 <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />PLASTER STOP THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />CONTINUOUS BACKER <br />ROD & SEALANT DRIP SCREED PLASTIC <br />ACCESSORY <br />A <br />roz <br />I <br />SOFFIT/CANTILEVER <br />0 <br />O <br />O <br />O <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-7 Ground 7 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FOUNDATION WEEP SCREED <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH -1 <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS L <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />- - DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />NSF LATH <br />i <br />---- JAI <br />;TOP A <br />US BACKER ROD <br />OUS FINISH <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant fleshings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as 0in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (611 x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />.Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />L� <br />o co <br />0 <br />0 <br />N O <br />z o <br /><c <br />N <br />CU) <br />M <br />, C <br />/1� O <br />1- ' <br />W n <br />J a <br />- <br />o W <br />tN c E <br />U °' <br />i� <br />F- m E <br />O $ <br />® W <br />= <br />U o <br />Q o <br />• <br />N N <br />LU n d o w Z <br />Z LU <br />�Z <br />v m z P W <br />us�LL.oW a <br />Z Q ��'ga_ o <br />Z C N O <br />A <br />V 2 E (gip d <br />LL Z <br />W Q NaM tg o <br />Li Li <br />0 <br />N <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Flodda Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o <br />w <br />c`) <br />o <br />ao <br />Z <br />� <br />ce E E <br />0 <br />oo <br />a0 <br />® <br />Co <br />I_ C <br />xU <br />�¢o <br />U0 <br />o0 <br />o E <br />CD¢ <br />as <br />ao <br />a <br />¢W <br />C <br />z <br />Y <br />mo <br />O <br />Z <br />Cf)<W <br />� <br />�w <br />go <br />a <br />r <br />� <br />NLL <br />z <br />CD�F <br />w¢ <br />>_ <br />a <br />�O <br />0 <br />^L1 <br />W <br />1 <br />C:)M <br />C:)�-� <br />L1. <br />(n <br />C:)Q <br />C " <br />(V <br />CIU <br />L./11 <br />0 0 <br />m C <br />3 <br />r <br />co rn <br />r <br />d' <br />.- a o <br />T <br />LO <br />T <br />r <br />LO M N <br />o <br />O �; t\ <br />Z <br />Z <br />E o (n <br />E <br />Za <br />C <br />a. <br />0 � ¢ o <br />3 <br />JOB <br />NO: 19-5892 <br />SCALE : AS NOTED <br />SHEET NO. <br />W P <br />