Laserfiche WebLink
N <br />M <br />to <br />Q <br />-4t- <br />rn <br />J <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates &devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FPP <br />DUPLEX OUTLET ABOVE COUNTER <br />0wP <br />WEATHERPROOF DUPLEX OUTLET <br />� GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />iP4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />1 <br />200 #12 copper to 20 amp Me00 AMP <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN �.t. <br />210 or 4/0 SER Alu <br />200 amp <br />150 amp <br />==1F <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING] <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />7f— WITH CODE APPROVED <br />NEC 14, 250.94 <br />—/ CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />FLUORESCENT LIGHT FIXTURE <br />co <br />EXHAUST FAN <br />— — <br />�Or <br />EXHAUST FAN/LIGHT COMBINATION <br />PA <br />CAFE <br />F_ <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />/ ' <br />I D. <br />CH <br />CHIMES (OPTIONAL) <br />qrC <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />-- <br />PENDANT AS "N' <br />D� <br />PUSH BUTTON SWITCH - DOOR BELL <br />PER SPECS \ <br />SD <br />SMOKE DETECTOR <br />/ to <br />` <br />CO <br />CARBON MONOXIDE DETECTOR <br />'A <br />�— <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />3 <br />GI <br />dB <br />TELEPHONE (OPTIONAL) <br />El, <br />DEDICATED RECEPTACLE <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />Wp H.B. <br />DISC. <br />FOR MICROWAVE RANGE <br />TELEVISION <br />GFI <br />HOOD PER SPECS <br />® <br />(OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />owl_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />��� <br />ROUGH -IN FOR OPT. CEILING FAN <br />�19 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />RI III IICD <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />i� <br />C <br />I_LIL, <br />m 0 <br />z N O <br />_ 0 <br />z <br />z o <br />v <br />¢ <br />r1 � <br />(nvl z <br />LL <br />1 <br />' <br />T Vi Y <br />WC) <br />�C <br />r/ O w E <br />c <br />Ln <br />�- `2 E <br />o <br />® w <br />I <br />z� <br />= <br />U ) <br />02 <br />¢ ° 8 <br />0 <br />N <br />� � N <br />LU o M� <br />Z W 8 '� 62:� � z <br />g v w <br />V <br />a'Eo��o <br />D����w oa <br />Z 96 x o <br />Z =moo <br />g <br />W Q N¢ r o <br />O U U F <br />00 <br />rn <br />0 <br />N <br />M <br />co <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seat is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o <br />CD <br />W <br />M <br />z�o <br />Z <br />o <br />E <br />�o <br />a <br />Z® <br />oa <br />U <br />F- Cl. <br />U <br />w0 <br />0 o <br />� <br />U� <br />Zo <br />racli <br />i <br />�r <br />a� <br />Wz <br />¢ w <br />� <br />rp <br />O <br />2 <br />U <br />.9 <br />ms <br />O <br />0 <br />Z <br />Z <br />) <br />W <br /><� <br />Q W <br />� Z <br />�, <br />a <br />s <br />° <br />U <br />W <br />Q- <br />LLLL <br />a <br />N W <br />� <br />coo <br />�Z <br />Jz <br />o <br />.J <br />v <br />.5 <br />a <br />° <br />C O <br />0 <br />nL' <br />W <br />> <br />� > <br />■ <br />O <br />W <br />C) <br />Q <br />C co <br />� <br />N <br />W <br />ter}. <br />U <br />r'h <br />v <br />■.r. f <br />LO <br />r <br />N <br />ctiZ <br />Z. M N <br />O N <br />o <br />Z <br />c <br />E Q m <br />0 <br />f6 <br />a <br />o a m <br />v Q o <br />JOB <br />NO: 19-5892 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />