My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39946 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39946 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:43:46 PM
Creation date
2/19/2025 10:08:22 AM
Metadata
Fields
Template:
Building Plans
Street #
39946
Location
Dawson Chase Dr
Contractor
Lennar Homes
Building Plans - Permit #
21899
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS _ <br />--------------------- <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />12 <br />5� <br />12 <br />5� <br />— €XTE-NDE-D <br />OVERHANG TO BE <br />CENTERED ON DOOR <br />6-0" — <br />-------------- <br />4' RIDGE VENT <br />12 <br />�5 <br />18' RIDGE VENT <br />T.O.M. <br />HDR <br />0 <br />00 ao <br />F.FL, <br />REAR ELEVATION - B1 <br />SCALE: 1 /4"=V-0" <br />LEFT ELEVATION - B1 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED, LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />'"'CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN — <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN, OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA I UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />CC:=::DD <br />1 <br />cm) <br />M <br />� N <br />Q M <br />N <br />E3 <br />U)V) M <br />Z <br />Q ) CDo <br />i C/a y <br />r.,., g <br />o a <br />{, <br />w F- <br />N c E <br />o <br />F— <br />U 0° <br />L.Li m <br />12 0 8 <br />I <br />U <br />r 0 <br />�C m <br />m <br />N <br />,/mil N <br />O � � <br />H <br />g o o w z <br />ZF���o � a <br />w <br />- 7 a <br />LU - <br />_ <br />LUQ ��LLCW <br />cia.a �o z <br />O <br />W,N <br />F1� <br />�❑ <br />CM <br />0 o��. <br />d J�O <br />i <br />•'• F \'. <br />7///(/'fill <br />t 11111\0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />C:, <br />C13 <br />w <br />z <br />J <br />U_❑ <br />Q E <br />o <br />z <br />oo <br />wi <br />>m <br /><k <br />z® <br />oa <br />co <br />t--- <br />X O <br />0 OU <br />O <br />C:'Qz <br />N t <br />U <br />a� <br />o <br />G <br />0. <br />ir¢ <br />wz <br />¢� <br />W <br />L <br />(p <br />C <br />p <br />z <br />Y <br />U <br />Nm <br />g <br />m O <br />o- <br />z <br />Q% <br />cn J <br />0'. <br />Q W <br />zz <br />0) <br />Q <br />0'. <br />LL <br />g0 <br />aw <br />m <br />�k <br />C)Sao <br />yz <br />=3 <br />O <br />(51 <br />YO <br />a <br />MJ <br />O <br />d <br />zIa <br />OL <br />3 <br />C O <br />O <br />M <br />^L11 <br />W <br />It <br />•> <br />O <br />O <br />L <br />O <br />0 > <br />N <br />m rr' <br />Ln <br />Ln <br />r <br />= d' It N <br />L f) <br />r <br />T <br />� r <br />0 Ch M <br />o <br />m <br />z <br />j O iri <br />E 10 �' <br />z <br />m <br />n. <br />E <br />U 0 Q p <br />c <br />a) <br />JOB <br />NO: 19-5891 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.