Laserfiche WebLink
A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN A <br />1/4 If = 1 '-0" <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /4„ = 1 ,-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 <br />#12 copper to 20 amp ckts <br />200 AMP <br />00, #10-2 copper to WH <br />00#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />} 0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING�250.50& <br />250.5 <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />JUN 2 7 7093 <br />Virtual Review Assist. Inc. vP <br />Mans Review completed and appro <br />for complianceth <br />Klahr PX2300 <br />y <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />co <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET cn <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANLIF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />sw STRUCTURED WIRE OUTLET <br />u- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />-ems 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />B CLG MNT PREWIRE - FIXTURE BY OWNER <br />CI} SURFACE MNT FIXTURE <br />{ WALL MNT FIXTURE <br />NOTE: <br />TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />C 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CosCOMBINATION <br />DETECTOR <br />C SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />-D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9�:24:;�l 24" VANITY LIGHTING <br />F� 36 � 36" VANITY LIGHTING <br />b­... 48 48" VANITY LIGHTING <br />0 EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />>� MASTER STATION <br />ELEC PANEL <br />M VACUM OUTLET AT 12" <br />WA CEILING RETURN AIR <br />® A/C REGISTER <br />C THERMOSTAT <br />® SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br />> <br />W <br />L �D 0 U <br />N <br />M CO d <br />N <br />V_ M <br />L i <br />2 0 <br />'T1�,11 <br />00 O O <br />O Q <br />U�° �# <br />-t <br />,N <br />V LU QC� <br />0O <br />W <br />L E P) <br />Lu <br />i w0HWr2zW w� <br />W02 �Y <br />X_j(1)0-QU <br />~I— <br />Zrpi-DW¢¢L�IJ, <br />0O00_OOJmozQ <br />UJ (Lu z0U <br />O OnO <br />U' <br />Z <br />a>WWF.zLL�QpJ pz�zOwUO <br />_QQLuLuz <br />Q~pw �_�� <br />oZ�� <br />a <br />Q <br />LL <br />�Lu <br />OQ o O�QLL <br />f <br />O <br />O <br />N <br />® W <br />> L O <br />CD <br />Q U) <br />J U-) <br />U <br />LL <br />LU <br />Ui <br />< <br />Z <br />00 <br />� <br />z � <br />W <br />Jo <br />d" <br />Nco <br />N <br />co <br />N <br />CD <br />N <br />CD <br />N <br />0 <br />N <br />O <br />A <br />T- <br />N <br />O <br />N <br />O <br />N <br />O <br />O <br />O <br />O <br />O <br />mi <br />0 <br />m <br />r- <br />0o <br />T- <br />co <br />r <br />O <br />N <br />O <br />O <br />CD <br />N <br />CD <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />N <br />O <br />O <br />0p <br />Oi <br />N <br />-r-- <br />M <br />i <br />O <br />O <br />O <br />O <br />O <br />O <br />O <br />r- <br />O <br />N <br />O <br />0 <br />0 <br />N0 <br />Y! <br />i <br />N <br />0 <br />M <br />0 <br />4 <br />0 <br />6 <br />0 <br />Or,� <br />0 <br />LO N7 <br />Cr <br />M (f) <br />Z Z <br />O <br />vV <br />owv� <br />w — <br />O o <br />Q <br />2o�o <br />�Q <br />�^ <br />~ <br />Oa=a <br />L <br />Z <br />ZLUif- <br />ry <br />TIIIIIIIIIIIIIIIII`� <br />mOz <br />(�O�w1 <br />Z <br />>-2ZWTI, <br />Z Z <br />Lo <br />W �; <br />a <br />Og2z <br />U�ZZ <br />d W <br />O <br />Z T__" <br />Q0 <br />. <br />Z <br />U <br />U� <br />O 0 <br />�- 00 <br />zA6 <br />Q <br />z <br />z <br />w <br />J <br />WC?) <br />N <br />r <br />N <br />O <br />LAST PLOT DATE <br />>N <br />May. 8, 23 <br />z 0 <br />1 ST & 2ND FLOOR <br />I <br />ELECTRICAL PLAN A <br />=-7r--,� - - - - - — - - - - -- _ t r —.--. - ��.-ll lT (,.rnr-C i�T lT�il7 nk. t s ii,im <br />