Laserfiche WebLink
STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED------_,,,,. <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING <br />COUNTER FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING <br />PT 1X10 BLOCKING <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />CEMENT MORTAR <br />TILE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />3rr=1 r-Orr <br />n=1 r-no, <br />WALL SHEATHING PER PLAN <br />STUCCO ON FRAME - 7/8" 3-GOAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP) <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED----__ <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING--------_ <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL --- <br />PT 1X BLOCKING <br />COUNTERFLASHING <br />00 PAN FLASHING 6" MIN <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6"---- <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS <br />2X NAILER SECURELY <br />FASTENED TO DECK <br />ROOF SHEATHING <br />NOTE: PER PLAN <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE <br />OUT OF CORROSION <br />-RESISTANT MATERIAL <br />HEAD WALL <br />ROOF PER SPECS <br />4YMENT <br />ALE OVER <br />3E <br />!EATHING <br />N <br />3E <br />FASCIA <br />HERED WRB TO <br />OVER WRB ON <br />!LOW <br />JM BRAKE METAL WRAP <br />�CKER ROD <br />SLANT <br />'T MOULDING <br />:F BRAKE METAL <br />ON FRAME - 7/8" <br />SAND FINISH STUCCO <br />FURRING LATH ON 2- <br />OF WATER RESISTIVE <br />COMPLYING WITH <br />556, TYPE 1 (TYP) <br />IEATHING PER PLAN <br />RAKE WALL <br />WP16 <br />WP18 <br />FLASHING REQUIREMENTS <br />FIBER CEMENT SIDING R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />PER ELEVATIONS WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. to <br />>O �?i =3 <br />WALL SHEATHING PER PLAN L <br />WALL SHEATHING PER PLAN R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />SHINGLE WATER RESISTIVE AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER O Q Ot L <br />FIBER CEMENT SIDING WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE C cu -0 0-- <br />BARRIER OVER FLASHING PER ELEVATIONS EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO }' O, N <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. =3 cu'! - cn <br />STARTER STRIP — SHINGLE WATER RESISTIVE N �-� <br />BARRIER OVER FLASHING R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO, ASPHALT FELT, FREE FROM C OL <br />HOLD 1/4" AIR GAP HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED O Q O O <br />BETWEEN SIDING AND STARTER STRIP WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL O O O' LL <br />FLASHING HOLD 1/4" AIR GAP EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE CIO EXTERIOR CUL O > <br />BETWEEN SIDING AND UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE .N E O <br />COUNTER FLASHING JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED U) O L Q <br />FLASHING MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE cn <br />cu Q <br />CONT SELF ADHERED FLASHING TO C6 <br />LAP FLASHING AND TURN 3" UP WALL CONT SELF ADHERED FLASHING TO BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT H -0 cf) Q <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />PT 1X10 BLOCKING PT 1X BLOCKING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />CONTSELF ADHERED FLASHING COUNTER FLASF'ING <br />TURN 3" UP BLOCKING— R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />00 TURN <br />PAN FLASHING 6" MIN INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />CEMENT MORTAR <br />SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />ROOF UNDERLAYMENT TO PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />TILE ROOF PER SPECS TURN UP BLOCKING MIN 6" INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF UNDERLAYMENT TO CONT SELF ADHERED FLASHING PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />TURN UP BLOCKING MIN 8" TURN 3" UP BLOCKING ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING TILE ROOF PER SPECS <br />PER PLAN EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />2X NAILER SECURELY WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />FASTENED TO DECK THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />ROOF SHEATHING DESIGNED DRAINAGE SPACE. <br />PER PLAN <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />HEAD WALL RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ROOF TO WALL - BARREL TILE TO SIDING ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />" r <br />_ W P 17 BUILDING STRUCTURAL FRAMING COMPONENTS. <br />31 -Orr SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />�. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW } <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />AND SIDES. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />REGISTERED DESIGN PROFESSIONAL. <br />1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />COPINGS AND SILLS. <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM, <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />7.7 AT BUILT-IN GUTTERS. <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />0 <br />0 <br />40, <br />?, ?0?3 � <br />Virtual <br />trtr Cplans RIV!ew � V/ew Assist In <br />mplience w/Chmpleted th and c. Co. <br />by Uehra Pproved <br />,Q7,70 K ahr p020 X ' h Edition <br />?3pp3: <br />w <br />z <br />z <br />J <br />U) <br />cu <br />O <br />L <br />Q <br />U <br />O <br />L <br />0— <br />cu <br />m <br />SHEET NO. <br />WR 2.1 <br />