Laserfiche WebLink
STUCCO CASING BEAD WITH <br />WEEP HOLES OVER FLASHING <br />ELEV AT 8'-0" A5 <br />T.O.M. <br />SHINGLE ROOF <br />= 9 <br />A5 7/8" STUCCO <br />r — OVER PLYWOOD <br />1 <br />1 1/4" THK x 6" <br />2 STUCCO BAND <br />5 I-- <br />i <br />M FE: 11 <br />I <br />I � <br />I <br />I <br />I <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />SHINGLE R( <br />ELEV AT T-0" <br />T.O.M. <br />5/8" STUCCO <br />OVER CMU <br />ELEV AT T-0" <br />1 ST FLOOR FF <br />REAR ELEVATION A <br />1 /4„ = 1 '-0" <br />ELEV AT 8'-0" _ <br />T.O.M. <br />co - I flo <br />F7F7 a a a F o a � SIMILAR5/8" STUCCO <br />EaCMU <br />FRONT ELEVATION A <br />3/8" = 1'-0" <br />5/8 STUCCO <br />OVER CMU <br />C? <br />O <br />ELEV AT 0'-0" <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />1ST FLOOR FF <br />RIGHT ELEVATION A <br />, 1 /4" = 1'-0" <br />12 <br />5F___ <br />ELEV AT 8'-0" <br />T.O.M. <br />W_ <br />zo <br />75/8" STUCCO <br />OVER CMU <br />ELEV AT 0'-0"- <br />1 ST FLOOR FF <br />CLEFT ELEVATION A <br />� � 1 <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />12 <br />5 MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />} NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />-JOVERHANG DETAIL <br />7/a11 _ 1 1-ni, <br />ROOF FINISH PER <br />ELEVATION <br />ROOF SHEATHING <br />' <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION Ot <br />ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />6 <br />1-ni, <br />�/d11_ 1 <br />ti <br />FOAM BAND <br />5/8" STUCCO <br />FINISH <br />FOAM BAND <br />CMU COLUMN DETAIL <br />1 alIA11 _ 1 1-ni, <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE, <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />NOTE: <br />FOAM TO BE USED ONLY WHEN <br />REQUIRED BY COMMUNITY <br />SPECS. IF NOT, DETAIL TO BE <br />BUILT W/ STUCCO <br />VARIES PER OPENING <br />811 ,_ 2" THICK <br />1-1/2" THICK <br />N`3 1 /2" <br />le <br />CO <br />I� <br />VARIES PER OPE Virtu I RevipW <br />or co ple Assist . Inc. <br />+nplianc m and ap <br />8 ELEVATION DETAILS lone ��:, t' <br />#11a = 1 1_7 <br />4" 10" <br />T <br />N 4„ „ <br />2 LB EPS <br />9 BRACKETS DETAIL <br />1 _n <br />N <br />M <br />co <br />sue. <br />O <br />l..s <br />y <br />Lo <br />a <br />o <br />w <br />Ln <br />ei <br />tL.A 'Yt'';i15 , J` ft <br />Q <br />y� <br />xu, <br />O�^a <br />1 <br />W <br />0 <br />z <br />Q <br />/N <br />A' N O N O <br />"o q U <br />!1 <br />�' M D <br />to <br />,�.., <br />V -0 -0 f ) M <br />O U o <br />o <br />ram 0 IL o O Q <br />U 10 <br />LU QN <br />N <br />i o E� <br />O a a) <br />C/ <br />W <br />0 <br />LLl Uj W 0 <br />�-< W =¢�zX <br />O= LL U OLL O <br />U <br />ia- <br />¢ X J 0 p <br />J <br />U <br />F- <br />0 <br />CgwRgOZOROomz� <br />n W W = ¢ <br />W Z <br />aQwO aQZ W232o0¢ <br />OQ o 0 0Qc Ir <br />�¢LL <br />O <br />O <br />Z W <br />cM 0 <br />Q w co � <br />w LL_ <br />ti <br />z <br />F- 0 M_ <br />� 0- � O <br />>_ <br />Z U H <br />z <br />W <br />W <br />J O <br />O <br />r� <br />I <br />I <br />I <br />1 <br />i <br />N <br />N <br />CD <br />N <br />ce) <br />Lo <br />O <br />N <br />O <br />N <br />o <br />jZ4 <br />N <br />0 <br />O <br />co <br />O <br />N <br />N <br />M <br />N <br />O <br />Z <br />r <br />(] <br />I <br />0 <br />1 <br />1 <br />' <br />O <br />NWoC <br />Lo <br />Lo <br />i <br />CV <br />M <br />C�c <br />-' <br />tp <br />; <br />' <br />Z <br />v J <br />r <br /><Z <br />W <br />0 <br />Z <br />}+ <br />}� <br />M O <br />W <br />U <br />OZZ <br />W00 <br />^ <br />i1 <br />O <br />UU�5 <br />:DZj <br />Z <br />0F_0 <br />a�a <br />Q <br />= <br />w=a <br />_ . <br />In <br />0 <br />mWw <br />ZOO <br />LU <br />Lr) <br />O <br />zwo <br />�■ <br />0 <br />UaZ <br />ry .1, - <br />Z <br />Xz <br />F- <br />� <br />OU <br />O <br />LL <br />z <br />A5z <br />Z <br />W <br />W r� <br />0 <br />NN <br />0 <br />N <br />LAST PLOT DATE <br />• <br />May 4, 2023 <br />ZO <br />j <br />EXTERIOR <br />ELEVATIONS A <br />