My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6478 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6478 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:23:21 PM
Creation date
2/19/2025 10:09:58 AM
Metadata
Fields
Template:
Building Plans
Street #
6478
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6616
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OWNER'S SUITE <br />T-10" <br />3 GREAT ROOM / <br />Q / <br />/ 6'-3" <br />---� <br />i <br />W.I.0 I <br />/ 5'-7" <br />— A ISC <br />O. BATH <br />LC <br />® w DINING <br />\ C? <br />I I GF AT 30" <br />I A.F.F. <br />5'-7" FOR / f <br />lio <br />HOOD <br />FI <br />KITCHEN <br />-,O <br />0 w 0 ' <br />%y <br />in BEDROOM #3of <br />GFI <br />GF AT 30" GF AT 30" <br />cs `_° cs I •� A.F.F. A.F.F.44 <br />N <br />r <br />BEDROOM #2 i 2'-10" 2'-2" 64" <br />5'-0" - <br />�.—• <br />GF GF <br />I <br />i 1 \ E rt <br />\ BATH #2 r �. <br />• I E� I <br />FI Co / <br />LIGHT & Eft iT _ GFI \/ <br />SWITCH IN <br />L � AHU <br />-----ih <br />ELECTRICAL Cn <br />METER A <br />ELECTRICAL 2'-9 <br />PANEL FOYEI <br />O <br />— • LAU N DY <br />TWO CAR GARAGE / . GFI <br />48 W D WP <br />GFI 110V CL'G <br />MNT. OUTLET <br />------------- -------I <br />I � I <br />I � I <br />I � I <br />I <br />- -d <br />PORCH I <br />NOTE: <br />ENTRY PER ELEVATION I <br />ELECTRICAL LAYOUT <br />J DOES NOT VARY -- ---- <br />ELECTRICAL PLAN (ELEVATIONS A & B) <br />1 /4„ = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />01 #15 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />TYPICAL 150-200 AMP ELECTRICAL <br />RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />co <br />SWITCH <br />4 1/2" <br />DOOR JAMB DUPLEX <br />OUTLET M <br />TRIM - <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o <br />k <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />Er 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />' TELEPHONE OUTLET AT 12" OR AS NOTED <br />-I} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />�- SWITCH AT 36" <br />6- 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-O PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />-{1 PUSH-BUTTON DOORBELL <br />{A} CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />{}- SURFACE MNT FIXTURE <br />}- WALL MNT FIXTURE <br />NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />41 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />C APPROVED BY <br />O_ 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�o� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CosCOMBINATION <br />DETECTOR <br />O SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 1 48"CLG MNT WRAPPED FLUOR LIGHT <br />5;24:R 24" VANITY LIGHTING <br />9RFF36;-,R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MEKI- MASTER STATION <br />_0&3 ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />E3 A/C REGISTER <br />OT THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />E <br />0C�l <br />W L Q U <br />\J� rn cort� N <br />t <br />t' Z) C) M M V co <br />•L i <br />0 2 00 <br />,�. 0 <br />tLo x Q <br />.N <br />JC } <br />V w Q� <br />W <br />L CD E <br />a °'00 <br />LLI <br />�LI Uj w0� <br />W�_ W J W 2�_ O <br />�02_j¢GQ�aLLU000 <br />Q Q <br />F- <br />V <br />1= <br />QOXOJZxu �Z��oHQQ <br />CyUnx9GZ0M00M <br />Z U <br />((n� <br />Z <br />-jOZZLLJ ZL <br />dY�oQL <br />¢0�w <br />OWg�0 <br />LIL <br />Ow � <br />p2U <br />Z�Q¢ <br />LLa O <br />LL <br />O <br />z <br />w <br />O I'- <br />ti <br />Cn O <br />z <br />F.cMO <br />Q U) M � <br />LL <br />z <br />w < Lq <br />I—B_i-M <br />'0�o-2T. <br />00 <br />Z0 <br />z <br />WIII <br />j 0 <br />O <br />d' <br />Jilt <br />�203 <br />Virtu <br />Plans Revi <br />l R <br />w c <br />vie <br />MbI <br />A0s <br />tddap <br />stt, I <br />Ic <br />for complianc <br />wit <br />the <br />202 <br />n k! <br />7th <br />Edition <br />by De <br />a A <br />ne Klahr <br />I <br />I <br />PX2 <br />00 <br />N <br />N <br />N <br />N <br />o <br />N <br />N <br />N <br />N <br />C <br />C)N <br />i <br />N <br />N <br />z <br />C)C) <br />o <br />I <br />C)I <br />I <br />' <br />0 <br />NW <br />o <br />0 <br />0 <br />0 <br />I?I <br />I <br />Lo <br />> <br />� <br />N <br />co <br />� <br />to <br />M� <br />Z~ <br />zz <br />w <br />C) <br />4-1z <br />�- <br />.� <br />O <br />W <br />U <br />z <br />000 <br />0L)(1) <br />Lo <br />�w� <br />i._o <br />Z <br />w�� <br />® <br />I_ <br />W=F <br />(� <br />H~� <br />��} <br />V <br />~0 <br />zoc=� <br />w <br />I-iD <br />. . <br />(.0Q <br />O <br />04 <br />(� <br />gam° <br />ww <br />z <br />z <br />a <br />�z <br />U <br />_3 <br />O <br />IZ <br />MMO <br />W <br />o: <br />z <br />z <br />z <br />z <br />w <br />W <br />J <br />O <br />V <br />N <br />O <br />LAST PLOT DATE <br />• <br />May 8, 2023 <br />z <br />6-0 <br />- 0 <br />J <br />ELECTRICAL PLAN A B <br />
The URL can be used to link to this page
Your browser does not support the video tag.