My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6497 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6497 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:32:17 PM
Creation date
2/19/2025 10:10:26 AM
Metadata
Fields
Template:
Building Plans
Street #
6497
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6785
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- -- r I 1 - - - - -- - <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />I ` <br />FAMILY \ \ <br />ROOM / 0 C \ \ \ <br />I F <br />6-7" <br />�\ 6-5" I <br />OWNER <br />\ SUITE <br />REF FI <br />KITCHEN I, <br />\ 4/ <br />GFI AT GFI <br />30" A.F.F. — <br />u i FOR <br />4'-3' n u u - HOOD I I `" <br />u o \ <br />u i To C° GFI GFI / <br />�I n ur- ISP I <br />u '. <br />OWNER 1 -5 N <br />u u ° BATH <br />u n (A 4 <br />DINING\ p --- <br />ROOM 1 <br />GFI AT i I GFI <br />30" A.F.F.i pW <br />'3'-8"j 3'-0"4' 0„ <br />A <br />GFI <br />GFI W.I.C.I <br />GF 2'-3" <br />° ANTR LILIT <br />GFI c GFI <br />A <br />A A A <br />PWDR _ <br />BATH <br />ce)iv 2 3,_7 Fv 3�_2��- - - <br />OS D <br />FI <br />1 LINE OF <br />FLOOR LIGHT AND <br />- - - I ABOVE 77-,- - -k SWITCH IN <br />ATTIC ELEC <br />METER <br />' L_ - - -j ELEC <br />TO2ND \ I PANEL <br />FLR ELEC <br />FOYER 48 <br />110V CLG <br />I o MNT. <br />--- --- `V OUTLET <br />i <br />GFI i GFI GFI <br />------ ---— — — — — — — — — — <br />I q <br />LENTRY rGFI I i <br />i <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-011 <br />LINE OF ROOF <br />M 1r1 �%Af <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4'1 = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST S FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�— 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET co <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ_ <br />SC_'SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />it 110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT 1HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />�-- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />PUSH BUTTON FOR GARAGE DOOR OPENER <br />-� DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE Jul <br />{} CLG MNT PREWIRE - FIXTURE BY OWV <br />�/ <br />-{} SURFACE MNT FIXTURE Virtual Review Assi i <br />Plans Review completed <br />WALL MNT FIXTURE for com diance with the gn 0 1 <br />40W A 6" ROUND OPALEX - tx(Nlba tKIa r <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />C SMOKE DETECTOR <br />°U-182 UNDER CABINET 18" <br />=S-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9724:R 24" VANITY LIGHTING <br />FF;F 36 ;;;R 36" VANITY LIGHTING <br />�48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />U 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />CM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />® A/C REGISTER <br />OT THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />co <br />N <br />0 <br />N <br />rn <br />Ln <br />Ln <br />LO <br />b <br /><� <br />W <br />_ r = <br />0 <br />W <br />0 <br />z <br />Q <br />N <br />�Il <br />OWN <br />> O o 0 <br />W <br />L 'L 0 U <br />in M d <br />} N M M <br />N <br />.�- <br />VD Om u a <br />E r <br />2-M <br />L O <br />O 2 o <br />O LL g m Q <br />• N <br />w a ^ � :4:oc) i _N <br />7W <br />V <br />L 0 �T <br />0 0a <br />W <br />�Wy 0 W <br />L.L. <br />�LLj N WOE <br />w�Q W�_j Ix9Yza Z <br />M0m <Oo Wa,600_jo <br />LLOZ O��QQ <br />C) <br />Q <br />=�XJ Z LLL <br />O CO W 9 O Z O 2 O o m <br />U,(a�<nWW�ZU-a¢OX-i <br />Z? U <br />OO <br />U) 0 z <br />Q p W O H� W <br />CL <br />2 U O Q <br />Y Z <br />oLL Q O 0 OQ <br />Q <br />O <br />O <br />zLU <br />OI_ <br />U) 5 ti <br />M <br />- <br />0 1O <br />Q � M � <br />z <br />W <br />I— W IZ M <br />00 <br />< <br />1 23 <br />Zv~ <br />z <br />W <br />WO <br />J <br />O <br />co <br />Inc. <br />approved <br />mi <br />C 7th Editior, <br />0 <br />0 <br />0 <br />t` <br />4 <br />4 <br />O <br />N <br />O <br />N <br />O <br />O <br />O <br />o <br />06 <br />ai <br />0 <br />T-- <br />00 <br />r- <br />O <br />N <br />O <br />N <br />O <br />N <br />r <br />N <br />N <br />O <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />LO <br />O0 <br />�t <br />0 <br />w <br />0 <br />o <br />T <br />o <br />0 <br />co <br />0 <br />NU-) <br />j <br />o <br />CD <br />O <br />O <br />CD <br />O <br />LO <br />mt <br />N <br />M <br />d' <br />V7 <br />CO <br />ti <br />Cr <br />CO <br />Z z <br />-ZO <br />O� <br />wLU�>- <br />WW(0 <br />O <br />V0�a <br />1- <br />0 CL <br />.� <br />z <br />W <br />~co0Z <br />N <br />(DZ�W <br />00 <br />�2zx <br />M <br />_Zz <br />N <br />��2z <br />0 <br />�zz <br />Q <br />Z <br />YQO <br />ry <br />I.. <br />Z <br />U <br />g <br />Ov <br />O <br />W <br />z <br />Q <br />z <br />W <br />J <br />WC14 <br />Q <br />LAST PLOT DATE <br />May. 9, 23 <br />Z <br />0 <br />1ST & 2ND FLOOR <br />� <br />ELECTRICAL PLAN <br />B <br />
The URL can be used to link to this page
Your browser does not support the video tag.