My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6619 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6619 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:39:53 PM
Creation date
2/19/2025 10:13:18 AM
Metadata
Fields
Template:
Building Plans
Street #
6619
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6458
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
00A <br />ELECTRICAL SPECIFICATION 150A/2 PANEL C NENTTER ER <br />C <br />DOOR <br />NOTES: <br />#14 to lights 8 outlets <br />NEMA 1 10 #12 to appliances and GFI <br />ELECTRICAL CONTRACTOR 2 0AMP/ 0 410 to WH <br />MUST VERIFY WITH THE 10 #8 to Range <br />SPECIFICATIONS FOR THE TYPE #6 to HVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES. MO <br />150=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />4 Bare Cu Ground <br />INTERSYSTEM <br />BONDING o #4 GROUNDING WIRE <br />TERMINATION PER 71 WITH CODE APPROVED <br />�J <br />NEC 17,250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />I. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8, Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.WEATHERPROOF DUPLEX OUTLET <br />P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />® SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />14 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />;Q EXHAUST FAN/LIGHT COMBINATION <br />P. <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />5 CHIMES (OPTIONAL) <br />�P PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />N TELEVISION (OPTIONAL) <br />N 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�M ELECTRIC METER <br />JD_ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />L J <br />�� <br />CEILING MOUNTED LIGHT FIXTURE WJ ROUGH -IN FOR <br />r J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />DISC. <br />WID <br />GFI ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />FAMILY R M <br />LIGHT PRE -WIRE � <br />G � <br />' GFI 1 <br />L UCI---_J <br />GFIL- -------_— JGf <br />r-� <br />D.W. <br />L <br />I K W/ DISP <br />'�AFE _ . ETC <br />PENDANT AS <br />PER SPECS \ FOR -DISPOSAL <br />PATIO <br />ANGEI- -- - <br />WID- <br />GFI �fi <br />I ---- <br />III, <br />/ I , \' <br />r' <br />l~Ql V <br />I lAV <br />21' @�kS�N i `2tr VT <br />3I R <br />C <br />„ W <br />31'. IQ <br />919 <br />4 <br />TO LIGHTS Tr <br />AND ITCH <br />ABOVE CEO TO M <br />ROUGH -IN FOR AIN <br />OPT. CLG. FAN/ — — — — — — — LIGHT PRE -WIRE PLUMBING RISER <br />12 SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />= I I — — — — _ / BE VERIFIED WITH PLUMBER <br />--- ----- � FLEX <br />--- / <br />SiORWID <br />I <br />-M !db =19P'�GFFI-------- <br />C.M <br />FOYER <br />GFI @ 44" <br />A.F.F. <br />L <br />I <br />� I <br />NTRY <br />I <br />I <br />I <br />'/, <br />O <br />r------------ <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />/ \ I <br />� \ I <br />I <br />I <br />I <br />-� GFI FOR I <br />-'-' GAR. DOOR I <br />PREWIRE <br />2 CAR GARAGE <br />I <br />I <br />I <br />)RFI @ 44" <br />A.F.F. <br />I <br />I <br />I <br />L------------ <br />VERIFY LOCATION <br />ELECTRICAL PANEL <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />GFI @ 44" A.F.F. <br />IRRIGATION <br />15'-0" <br />R1.3 <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />a+7 <br />'ev <br />Cn <br />o <br />9 W <br />� <br />o <br />1 <br />C= <br />c m-c e� � <br />_ m x <br />.% = L.L. d <br />o 0 <br />CC <br />E <br />c <br />CD .�. <br />�E <br />� v <br />� v <br />12 <br />M <br />CV <br />0 <br />CV <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential <br />7th Edition. Engineer's signature and seal <br />is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />r <br />Q <br />CD o0 ^�� <br />V <br />N 1 h J <br />0 <br />.� M N xc LL U_ <br />M y a a <br />Q <br />,v w <br />C _ a Y C7 <br />ta�� Z <br />ewe <br />Ca` <br />3 <br />Z <br />� <br />J -o rn O O <br />to <br />C)Y <br />a <br />N- <br />w , M W o <br />c <br />W <br />W <br />_ <br />oJm <br />cn�°'°' J Z <br />C)N o tY w <br />Z <br />oo <br />N co Z 0 <br />co <br />FF_ <br />o ❑❑❑ <br />�r W <br />o <br />W N <br />z o � <br />J1j <br />s. <br />r <br />N <br />M <br />0 o <br />va <br />LU <br />U <br />0 <br />V)01- <br />,-,., g <br />ues <br />�N:::D) <br />� <br />r— <br />Lu <br />EEo <br />i <br />4fV <br />ai <br />U o <br />c U) <br />Qco <br />m <br />N <br />ti <br />co <br />Z <br />W <br />M <br />M <br />N ¢ <br />0O <br />Z <br />Z <br />Q <br />< <br />41 <br />—r <br />U_ <br />z E <br />cz E <br />zo <br />o° <br />FZ <br />>P <br />ze <br />o�a <br />1—ni <br />�gUo <br />a <br />,E <br />gz <br />w0.wg <br />L <br />CO C <br />¢ o <br />Z <br />m <br />F o <br />oZ <br />z <br />Z <br />m � <br />.m <br />, <br />1w <br />3 <br />�� <br />W <br />go <br />c!� <br />T 3 <br />t <br />a Z <br />N W <br />W <br />C)4 <br />0 <br />az <br />o <br />w< <br />>° <br />Mill!3 <br />v <br />0Ia� <br />¢ <br />3 <br />.° O <br />2 <br />J <br />L J <br />L0 <br />m <br />M <br />,---. <br />Q <br />CID <br />0 <br />Itt <br />O <br />o <br />C:) <br />� <br />U)o <br />J <br />m <br />m <br />Ln <br />l,,, <br />o <br />T <br />+-I <br />U_ M <br />I <br />U-) <br />-0 <br />CC N <br />O <br />°° <br />Ltd <br />CU <br />M <br />r <br />T <br />cfl LO <br />io <br />E <br />c <br />o <br />Z <br />Z <br />E O <br />to <br />m <br />a <br />E <br />U °� <br />Q <br />c <br />J <br />JOB <br />NO : <br />23-06134 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />r - <br />
The URL can be used to link to this page
Your browser does not support the video tag.