My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6620 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6620 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:51:18 PM
Creation date
2/19/2025 10:13:40 AM
Metadata
Fields
Template:
Building Plans
Street #
6620
Location
Paden Wheel St
Contractor
Lennar Homes
Building Plans - Permit #
19001
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CORNER OF <br />HOME <br />GARAGE SIDE <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />.+++44-++++++++++++++++ ++++++++++++++++++++++++++ +++ <br />ol- [ <br />+ + <br />w 15/32" CDX <br />m PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />\++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+ + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + + <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/el <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-118" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap ° <br />k <br />+ > <br />FILL CELL STD. 90' HOOK BOND BEAM <br />w 7 a STD. 90° CONT. #5 <br />BAR , CONIT. #5 > HOOK BAR <br />#5 CONT. <br />FROM <br />]� NDATION <br />JL <br />TOHIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" max <br />/ . � 4 max. <br />"r 4 <br />__7Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />" local building <br />code for appropriate 1/16 <br />10 -0 details in One 10d box <br />TANK -LESS W/H areas=20 of high orz20 sinker <br />lateral load. nail each side <br />at bearing. <br />5'-0" <br />STUB -OUT FOR -' <br />GAS METER O <br />0 <br />H C G <br />00 O <br />a _ <br />�o <br />1'-0" 0 9 ' <br />o LO <br />U <br />0 <br />2 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR {4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4' <br />(1) USP HTW20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) �J <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />V% Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRIG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />Tight fit <br />2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series Depth End Intermediate <br />BCI5000s® <br />9-1/2" <br />24 <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />I 5- d <br />BCl6000s® <br />BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60sY" <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />6 A 1Y," ROUND HOLE MAY 6�� 6 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />8 <br />V-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />1'-3" <br />V-3" <br />V-7"' <br />1'-11" <br />2'-4" <br />2'-9" <br />3'-2" <br />3'-7" <br />Any 16" joist <br />V-1" <br />1!-2" <br />V-2" <br />V-3" <br />V-9" <br />2'-4" <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />�.---- <br />S pare (ft) <br />V-1 " <br />V-2" <br />V-2" <br />V-7" <br />2'-5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />T-2" <br />J241 <br />V-1" <br />1'-2" <br />V-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />W-11" <br />7'-11" <br />8'-11" <br />1'-1" <br />1'-2" <br />1'-T' <br />2'-5" <br />3'-7" <br />4'-9" <br />5'-10" <br />T-2" <br />8'-4" <br />9'-0" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1%" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10- 10d nails. <br />\Install tight to top flange. <br />Joist hanger <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D depth <br />1-JOISTS BUCKETS <br />N.T.S. <br />USP <br />MUC <br />5/8" 0 <br />THRU <br />BOLT <br />U� <br />MI. <br />R TRUSS <br />'OP PLATE <br />If <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />TYPICAL HTA 20-18 / HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />NEW <br />SLEEVE THRU STEM- / a ° ° <br />SEE PLAN FOR--'°• ° .. <br />FOUNDATION INFO <br />STEM FOUNDATION <br />GRADE <br />REINF. SEE PLAN <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />FINISH GRADE <br />�A/C CHASE 4" PVC'__ (2) 45 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF NOTE: <br />UPLIFT VALUE <br />SECOND RT16 IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d x1 1/2" NAILS <br />' UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" v <br />CENETERED @ PIPE <br />PENETRATION <br />4- d..d I la <br />I I • ' <br />TT <br />III—.. :..I i.a <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />F� <br />ICI <br />��— <br />SEE FND. PLN. <br />SIZE & REINF. <br />BELOW <br />G <br />GRADE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />q 4 d <br />a a <br />—-------- <br />---- �—as----� <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x T-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a a' e e <br />a P, I-1 I I —III: <br />a a a 1—I I I� � ,T— <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />C9 LO <br />M <br />o <br />z0 <br />o <br />_ <br />Z m <br />z <br />Q <br />i2 <br />f � z <br />l/) 0 <br />w <br />� p <br />0 W <br />E <br />�V) w— <br />m ti <br />i <br />U <br />W <br />~ E <br />0M <br />C (CI M <br />Er-2 N <br />U <br />= ai <br />0 O O <br />=LLo <br />U� <br />C <br />COo-o <br />Y <br />Q <br />LO O 73• <br />CL <br />rn Q o <br />At <br />NCB -D-C <br />B <br />®® <br />\31 <br />0 <br />N �f <br />ter <br />Wo <br />Lo <br />LL d <br />An llu�° N N) �N T``� <br />Dw�'' � <br />�� <br />N 04". <br />m <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z o <br />O N N <br />'—' 4-' O <br />i>+ (n M O <br />M <br />Q L '0 Ln <br />IZ V)z <br />0 <br />Q (1) — Ln <br />�- � M <br />Ura ,--I <br />z� E� <br />(O <br />W COO ~ <br />W <br />d- <br />J <br />Oz <br />w ii0 <br />W °� ¢ W Ln � <br />U0�cn00 <br />r z >_ z ¢ U <br />z>-QUEQ <br />_ <br />w Z <br />c�zoaw <br />aaU <br />00Ln <br />O H o � o <br />U = O W N <br />C)~aOZ <br />uJ o <br />M <br />"' <br />O <br />�J <br />rl <br />t\ <br />r� <br />Lr) <br />< <br />w <br />w Op � <br />`J <br />w000a <br />z <br />00 <br />90Z�mo <br />0� <br />0 <br />z C5,L2w: Uo <br />a) <br />z <br />LU <br />0N ;� <br />I—aJwU� <br />C) <br />Woi- <br />W O u z a <br />cy W 0 O <br />��Qoo <br />Ln <br />O8wo <br />V,wOwQ <br />{.L <br />l 1 <br />w 0. Y w <br />Q Q <br />0 <br />0 <br />LL <br />w <br />j <br />Z <br />Z <br />a <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: FFLORES <br />VERSION NO. <br />5oll <br />JOB NO: 17-5175 <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.