Laserfiche WebLink
I I I L L __ .r I. _ r 11 1 i ^1., , . A _ I <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />31EI" CEMENT <br />PLASTER <br />Y <br />1?. MIL DR - LOK. <br />M I - MASONRY <br />C L SO BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOW BUCK-,, <br />1 <br />21 SEALANT JOINT <br />L <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAMEWINDOW <br />BUC MACROSS <br />WINDOW BUCKAND <br />EXTEND 1C) <br />t.-WINDOWFAAME <br />MASONRY --_ <br />ATTACHED <br />PER COD= <br />6) IOOLEDSEALANI <br />RE+QUIREMEPiTs <br />BEAU BRIDGING <br />CLADDING AND WINDOW,, <br />FRAME <br />L 3) SEALANT WINDOW FRAME Tr <br />WINDOW BUCK ALL THE WAY <br />AROUND. INCLUDING .ILL <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />,IAMB, SILL AND HEAD D£TAIL. <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTAL.ATH TWIN TRACK 2.5 <br />14" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />WEATHER <br />- RESISTIVE <br />;. FARRIER <br />FOLD UP WEATHER <br />RES'ISTIVL BARRER , <br />TEMPORARILY SECURE <br />S Lr"21!-E <br />ti <br />•ter <br />Y <br />s EXTERIOR • <br />Sk LF ADIitrFL%) ,bd!r,°_� <br />`. <br />I <br />SHEATHING <br />1 r I ;'Ir,Id DOV <br />C,V I FRIM lO!S I AND A <br />WAI i RY (i IN <br />A <br />1r't+EA 1 HER <br />i <br />RESISITIVE <br />RARRIFR <br />UNDL -- DEC:KINC <br />V1F071 <br />V <br />SELF -ADHERED Fi-A`SHING <br />ISE.E:.)FTAIL <br />.}'I <br />HEAD FLASHING TIE-IN INSTRUXTIONS r ' <br />1. Gut, fold up & temporarily secure weather <br />resistive barrier above header to allow for <br />flashing Installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier ' <br />3. Fold weather resistive barrier back over heap (`2 t <br />flashing and seal wrath tape _..- <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW W PO 1 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />SI <br />E)0 NC,)l <br />BOTTOI <br />Fd.A . <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />f t { <br />r <br />I <br />I I I <br />SINGLE <br />I <br />MOIST <br />SELF -ADHERED <br />FLASHING <br />SCS 0602 WINDOW FIN INTERFACE= WITH SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER DECK JOIST <br />k�,, ilWv <br />F1 <br />DOUBt. E <br />JOIST <br />WOOD BEAM <br />BELOW <br />SELF -ADHERED <br />FLASHING !� <br />(2i <br />YYPV/ <br />SELL -ADHERED FLASHING 2xFRAMEWALL <br />PRODUCTS DETAILS TILE FINISH----,, <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as 0# in each detail that corresponds to the <br />numbered items In the list of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of comer may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />112" DIJROCK---..--__-_ <br />8" CMU ---9-- 4-------____ �� <br />4"ORC"CMU <br />(PER SEAT DEPTH)-'-__.___ -- <br />FILL WITH GROUT <br />SLOPED MUD BED - --_ <br />VINYL SHOWER PAN <br />a <br />-- <br />E �L" <br />i <br />SHOWER SEAT <br />ROUGH C)� <br />WINDOW UNI I <br />SLOPE <br />FLASHING REQUIREMENTS <br />0.3 in 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />s r .,• RI AD OF (0.6 cnt : 30.5 cm) include flashing as described in Section R703.4. <br />AD I[ SiVL TOBi AlIi, Ni;; d � - SEC.€=-ADHFHFD F1ASHING <br />rill HUi D 0IE L r 1r <br />F,r I .P� +F JAMB <br />t;x i ErdiOR R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />N �Fa61P°i:' �)'{! `�+IJ I !_I' within the wall assembly b providing awater-resistant barrier behind the exterior cladding as require b Section R703.2 and a means of <br />PP! r;F (,At _1LK!N( --- CI -MT. FIN y y p 9 g q y <br />- BUILDING; PAPER draining to the exterior water that penetrates the exterior cladding. <br />I-i F-ADHE.RE;; Y , A:,, i[N:_ <br />- > �--- WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />uI `7t R approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontal) <br />P P P PP y, <br />--., with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />- --= = approved materials shall be installed in accordance with the water -resistive banter manufacturer's installation instructions. The No.15 asphalt <br />effelt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />1 RIM JolS, appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />+- R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />SELF -ADHERED FLASHING � J©(' �1 SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A Y Y I 02 CEMT. FINISH SILL! POTSHELF/ CHIMNEY SHOULDER P03 <br />III =wic:; rat; MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT - <br />4"-1'BEA9 F ()NS1 :' NEEDED IN CORNERS ADHESIVE <br />- IN�T�L * °, -,F_1 L ASPHALT ADHESIVE <br />ADHESIVE Ti t F= Ai} 1 I' 1fIC f:Fi - - ---d % ,';` FLAst+r4 . ROUGH SELF -ADHERED THROUGH <br />1HRESHC11Lst�6 DOC )I, `,NDPLTI-)k '; FI-ASHIN ° t FLASHING -SELF-ADHERED FLASHING=_---., <br />dP JAMS f" ��5-- I It.,',1I(? !`.ill I�EtA^Ja L� �' I FIAM1 r_�i) '� <br />r r-_ <br />,b G <br />F' E.; (JI.IAd, °a'°JE,}. E I+F. R I'9,i,,.JF _ ii1JI � 11'FCi y - " 4: _ : • �,, I <br />SCORED _ <br />_ <br />- RELEASE PAPER <br />P a- <br />ITV '�i S <br />i VEPIIc Z, , sM.. <br />i <br />THRFSK <br />1If)N A S i F: t ,il v4r IE'i _ I it YI ti <br />it � �2 ' <br />Ft,I--ADHF=I,'E.LI I I �a"�°1,H1 JF:; 5 <br />4 <br />SEAL TOPS Oi Jt�'� i -- i 6 `I <br />L)Ni)FfJ DF'..FS1raCa <br />(SEE IA TAIL WF"'i� 2 <br />SEt F-ADHERED FLASHING �`] SELF -ADHERED FLASHING � <br />EXTERIOR DOOR WITH DECK W @"' 0 INSIDE CORNERj�/ Y Y P06 <br />Ground <br />- ATH1N - <br />- ----� + - - 4Natnr rlesrtanl Barrier <br />LF ADHERXD FLA.5HINC,_a <br />,TCH <br />1 '>SFLz ADHERED FLASHING -- <br />SELF -ADHERED FLASHING ; <br />3" M!N- <br />4'' <br />5 <br />SELF -ADHERED FLASHING X PH FOUNDATION WEEP SCREED <br />OU.lID1- �;OF�2NFR ti Y LlC3 <br />< d' <br />LU I j <br />u > `O d0 10RE AK !''IRE, <br />' r <br />Q <br />r !E VERTICAL <br />i=Ai. E TO TU:D <br />i AW-IL NS AN AIR <br />i k <br />t l" INt;Fi FLANr;F <br />l \ I <br />ti <br />-+ - -j' <br />CL <br />W i - '--- PHIS GAP IS A REtiI ILi ('_1f <br />W PI ASS FR ST,-,p 1 m: <br />d NA T UF;AL SHRINKf,GF <br />_ __ _ ?i_, NOT SEAL <br />W ONTlNt: BAGKI=R <br />W <br />W� <br />cn 0 <br />IU) <br />=JI a <br />-ath <br />sheathung <br />Sf ucco <br />I�OFFITICANTILEVER <br />LEUENU <br />S' F D'ILRLD ;-LASHING (`,AF) <br />DR.NNA1AFPLANE (fFrIWEA PiEHRL�ItiTAiVT <br />BARR!Ffi 1WRF3) <br />BOND P-REAK NEE ,IFR PES', A"it- <br />Sf.� <br />PL ASTE R AC( F SSORY _- <br />SHF <br />NTIN1 icl N'PA( .K FR HC',II \ <br />k N ANT <br />`AFNTI'I011- FINISH <br />STRUCTURAL FRAIJIN(i <br />,m TT0 P31 URAL SIiCHTHIN <br />STRIP Of SAF <br />DRAINAGE L'I ANF DIRE{ <br />BONE) BI F-AK ktq tR 6 <br />sheathing, shall Include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />Exception: Where the water -resistive barrier that is applied over wood -fused sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />R703.4 Flashing. Approved metal flashing, vinyl flashing self -adhered membranes and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />entry of water into the wall cavity or penetration of water to the building structural framing components. <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />flashing in exterior walls shall comply with AAMA 714. The flashing snail extend to the surface of the exterior wall finish. Approved flashings <br />shall be installed at the following locations: <br />1. 1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following: <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are <br />net provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. !Openings using pan flashing shall incorporate flashing or protection at the head and sides_ <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2, 2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />3.3.Under and at the ends of masonry, wood or rretal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />7. 7.At built-in putters. <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC 1063 <br />Building Paper <br />-7/16' O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Wee--) Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />112" Cementitious <br />Decorative Finish <br />All Inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />2 l 2023 <br />-"pry cnmPleted "r "'mPliance with the <br />andaPProved <br />,Iy u`�h,3 20Anne K ah� pX 300h Edition <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />4­! <br />C0 <br />(1)V� <br />O <br />4­, <br />W <br />O <br />'T <br />© <br />tQ <br />�- <br />Q <br />Cco <br />O <br />LL. <br />0 <br />CU <br />> <br />.� <br />Z3 <br />E <br />Cn <br />CU <br />CU <br />� <br />fl. <br />F- <br />-0 <br />C/) <br />Cn <br />CIO <br />MOM=# <br />_1111­0 <br />CD <br />V ) <br />ICU <br />■ �rI <br />� <br />L <br />rQr�� <br />V/ <br />M <br />Cn <br />Q <br />Z <br />ry <br />.! <br />Q <br />cL <br />SHEET NO. <br />WP1 ■ <br />