My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6640 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6640 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 5:56:34 PM
Creation date
2/19/2025 10:14:23 AM
Metadata
Fields
Template:
Building Plans
Street #
6640
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6614
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I I I I III 1 11 11 1 1 11111 1 1 <br />A/C <br />DICONNECT <br />WP <br />GFI <br />G, <br />I <br />I <br />PORCH <br />ELECTRICAL PLAN (ELEVATIONS A & B <br />1 /411 = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />10 #15 copper to lights & outlets <br />1 <br />pP #12 copper to 20 amp ckts <br />00 AMP <br />200 <br />#10-2 copper to WH <br />10- #10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />TYPICAL 150-200 AMP ELECTRICAL <br />RISER DIAGRAM <br />NTS <br />JUN Z 7 Zt�''J <br />Virtual Review Assist, Inc. <br />Plans Review completed and appro en <br />for compliance with the 2020 FBC 7th Ed' <br />by Debra Anne Mahr PX230P, <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH--,— <br />SWITCH- <br />0° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET ih <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />I SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />E)= 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />b- SWITCH AT 36" <br />Cl) 3 WAY SWITCH AT 36" <br />4, WAY SWITCH AT 36" <br />—O PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />} CLG MNT LT FIXTURE <br />-{f}- CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />{�} WALL MNT FIXTURE <br />NOTE: <br />TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />0 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />- CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos COMBINATION <br />DETECTOR <br />0S SMOKE DETECTOR <br />cU-18� UNDER CABINET 18" <br />cS-18a SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />5724:R 24" VANITY LIGHTING <br />5;;F 36 ;� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />GM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />Iffig-0 ELEC PANEL <br />El VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />E3 <br />A/C REGISTER <br />OT <br />THERMOSTAT <br />GE <br />SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />to N �O — <br />> 0 E <br />o <br />_� >r c 'o <br />ch v m <br />CO co <br />N <br />W <br />} M <br />(D E L t <br />W Z) O 2 <br />0 <br />OAS a Q <br />(_5 0 <br />�V V woc) a � <br />W L 0 �� <br />V, <br />W <br />ILL!LLIz <br />W <br />cw vi w0Uj � <br />�Q Lu <br />X x �z= <br />U� <br />Q Q U <br />xf)- J�O���LLL) <br />j d 0 Z x li 0 Z M 2 0 <br />ttoomgz <br />LL <br />H¢ Q <br />0 0 <br />o(0X9 <br />cnwawc)LuLLJ �o:¢0�.j <br />U <br />d <br />U) <br />Z <br />_jOa>zYOZZLL0LUZLU <br />< LLJ � � Y � <br />D_ <br />L) <br />ILL <br />¢ <br />oQ o 0 o¢QX <br />LL <br />i <br />O <br />O <br />Z CV <br />O� <br />D ti <br />0 � M O <br />Q M [8) <br />U) <br />�- 11 cz 00 <br />Z <br />Z <br />W <br />W <br />O <br />J O <br />I <br />I <br />I <br />I <br />I <br />I <br />O <br />N <br />o <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />O <br />O <br />a- <br />N <br />O <br />' <br />i <br />i <br />N <br />O <br />' <br />! <br />1 <br />� <br />Z <br />0 <br />N <br />W <br />o <br />> <br />e- <br />N <br />(M <br />to <br />i <br />' <br />00 <br />0 <br />zZ <br />() <br />¢z <br />w <br />O <br />W <br />ZW <br />000 <br />'a--0 <br />O <br />U <br />L)0� <br />O <br />�zj <br />OLD <br />Z <br />atra <br />�- <br />O <br />= <br />W=Q <br />T� <br />z O TZ <br />W <br />co <br />¢F-� <br />C� <br />< <br />O <br />WW <br />N <br />z <br />U <br />: x <br />gzUL <br />34 <br />Z <br />az <br />LD <br />?� <br />OU <br />a <br />_0 <br />W <br />Z <br />z <br />z <br />z <br />w <br />O <br />Lilqt <br />N <br />0 <br />0 <br />LAST PLOT DATE <br />O <br />• . <br />May 8, 2023 <br />-4-+ <br />� <br />J <br />ELECTRICAL PLAN A & <br />B <br />
The URL can be used to link to this page
Your browser does not support the video tag.