Laserfiche WebLink
3 <br />J <br />m <br />rn <br />Ln <br />v <br />Cn <br />O <br />-72 <br />0 <br />J <br />00 <br />[V <br />CG <br />0 <br />I <br />M <br />i <br />J <br />d- <br />rn <br />L0 <br />;v <br />v <br />CrC <br />0 <br />0 <br />0 <br />0 <br />J <br />lb <br />CV <br />C0 <br />I <br />4 <br />,[ <br />v <br />r <br />3 <br />H <br />t� <br />NC) <br />C <br />rv- <br />N <br />E <br />O <br />2 <br />0 <br />J <br />ID <br />0 <br />v <br />0 <br />LZ <br />N <br />0 <br />to <br />v <br />O <br />0 <br />0 <br />U <br />0 <br />m <br />LO <br />Cn <br />ELECTRICAL SPECIFICATION <br />150A/2 INDOOR <br />PANELL CENTER <br />NOTES: <br />00 #14 to lights & outlets <br />NEMA 1 <br />#12 to appliances and GFI <br />ELECTRICAL CONTRACTOR <br />20AMP/ <br />00 AMP <br />0 #10 t0 WH <br />MUST VERIFY WITH THE <br />0 #8 to Range <br />SPECIFICATIONS FOR THE TYPE <br />0 #6 to HVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />LOCATION PURPOSES. <br />MAIN <br />150=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />o <br />#4 <br />GROUNDING WIRE <br />TERMINATION PER <br />/1 <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqT- <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4 - <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I--O <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUSTFAN <br />;O) <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH I <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />I []sD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />L`i <br />kIT <br />W/ ..HL-, <br />PLUMBING RISER_ <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />DEDICATED RECEPTACLE <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1 r-0" <br />e� <br />y W <br />� <br />s <br />ar o <br />� N t <br />N N <br />O 3 . � cc <br />Cc N y <br />CJ <br />to <br />cc0 <br />C7 <br />CV <br />0 <br />CV <br />ch <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />.e <br />Q <br />O N U N r v <br /># <br />a <br />0N <br />0 <br />W <br />_�00y �LLLL <br />: <br />0) <br />9) <br />Q <br />cA o ° ul a <br />ai � w a <br />@LLB 0 <br />J Z <br />0.yyo_of� <br />' 't? <br />Z <br />O <br />C) <br />c0 CC <br />,. <br />;: it <br />LLI <br />� Q <br />o l� Q r m <br />r' <br />Z <br />- ry O R O Lu <br />LO c+� Z U 0 F <br />N Q <br />a, <br />Z <br />0 L) ❑❑❑ <br />W <br />0 � In <br />z N o <br />z m N <br />z o � <br />o <br />Q <br />J <br />(n <br />M <br />Q) <br />�N <br />z <br />(D o <br />w <br />� <br />O <br />0 U <br />N <br />m <br />�j �Q <br />(J � <br />w m <br />•,. <br />ii <br />d <br />a <br />A� <br />I <br />U O 41 <br />I� <br />o <br />Co <br />M <br />M <br />J <br />J <br />Z <br />Z <br />C <br />U- <br />rri E <br />U <br />ca <br />5 <br />Z. <br />� o <br />wz <br />>� <br />zo <br />a <br />oa <br />r0 <br />g0 <br />�o <br />p <br />w to <br />¢ <br />¢o <br />o <br />Z <br />�z <br />C <br />m J <br />U <br />o <br />m <br />w <br />N <br />oLL <br />Z <br />aw <br />oW< <br />�z <br />go <br />a <br />W <br />CA)U� <br />c <br />T 3 <br />lock <br />'o <br />w <br />r� <br />c, <br />� � <br />w <br />d <br />10 <br />zR� <br />§ <br />.N O <br />i <br />> O <br />J <br />m <br />cc <br />N <br />CID <br />0 <br />O <br />= co <br />r <br />iv / o <br />N <br />coLO <br />Q <br />M <br />�{' <br />co N <br />m <br />T <br />LO <br />CD -- <br />T <br />T <br />E <br />CO <br />o <br />z <br />cc <br />Z <br />E O <br />d <br />E <br />U -j <br />Q p 1 <br />-1 <br />JOB <br />NO : <br />23-06128 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />