Laserfiche WebLink
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />VENT OR 2ND FLOOR <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />TYPICAL C.M.U. WALL <br />2x6 / 2x8 WALL BEYOND <br />(2) 2x HEADER TO SIT <br />FLUSH TO THE OUTSIDE <br />STANDARD 3"DIA. TEE <br />3/4" FURRING STRIPS <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />1/2" GYPSUM BOARD <br />CONNECTION <br />SCREW OFF CAP (3" DIA.) <br />W/ DRYWALL SCREWS <br />2x DEAD WOOD @ MID <br />FOR CLEAN -OUT <br />@ 8" O.C. OR 4d <br />POINT w/ (3)12d <br />DRYWALL NAILS <br />MIN, EXTENSION FROM <br />DOUBLE 2x TOP <br />TONEAILS SPACED <br />EXTERIOR FACE OF BLOCK <br />EVENLY <br />1" <br />PLATE WALL IS 1 l2 MAXIMUM INTERIOR <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL <br />FACE OF BLOCK WALL IS 21/4" <br />Ct <br />TO DRAIN <br />2x BLOCKING @EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE EXTERIOR <br />TO BLOCKING WALL <br />(2) 2x HEADER WALL CLEAN -OUT A <br />PER PLAN SCALE: N.T.S. S4 _ <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8 8 16 BLOCK <br />12 <br />(TYP.) SEE ELEV. <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. <br />926 APPLY 3 LAYERS W/ TOTAL <br />THICKNESS 7/8" OVER METAL <br />LATH. FIRST 2 LAYERS 3/8" THICK <br />EACH. 3RD LAYER 1/8" THICK. <br />CRICKET AS REQUIRED <br />x x SIM SON SP2 w/ (12)10d ' <br />DI I/T NAIL AT EACH STUD <br />—DOOR OPENING DOOR OPENING —CL 1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" BLOCKING ( ) <br />❑ O/C FIELD <br />❑ 2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS - -' <br />VARIES BOTTOM PLATE WI (1)10d @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAMEK*"D� <br />WALL HEADER DETAIL 1 <br />SCALE: N.T.S. SQ <br />1ST COARSE 2ND COARSE 3RD COARSE <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />MASONRY LAYOUT <br />SCALE: N.T.S. S4 <br />SIMPSON HETA20 w/ (8)10dxl 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />IN KO BLOCK AT EA, STUD <br />MOISTURE BARRIER <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED W/ GROUT <br />REFER TO WINDOW PRODUCT APPROVAL <br />SHEETS FOR INSTALLATION INFORMATION BY <br />MANUFACTURER. <br />TYPICAL SECTION THRU WINDOW rW� <br />IL <br />MAIN SPAN <br />ROOF TRUSS <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />S4 <br />12 SEE TYPICAL WALL SECTION <br />(�Yp) SEE ELEV. PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />KNOCK OUT <br />NOTCH LINTEL WHERE REQUIRED <br />(SEE SCHEDULE) BLOCK W/ (1) #5 <br />DOUBLE 2x4 SPF. #2 FOR CONCRETE PLACEMENT <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12)10d (3)10d TOENAILS T&B <br />NAILS AT EACH STUD AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />STUD W/ (3) Od NAILS <br />«. <br />.' <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)10d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90A HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERAL NOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />—'' <br />f�i� <br />Milli <br />NOTES: <br />0 FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />--- PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />BLOCKING P. Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />-ROOF TRUSS O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />UPLIFT CONNECTOR (SEE SCHEDULE) ® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />-SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />G <br />S4 <br />WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO <br />1/2"X91/2" PLYWOOD CREATE A SOLID BASE FOR <br />BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />MOUNTING BASE SHOWN <br />IN POSITION <br />—2x6 MOUNTING BASE <br />J <br />r- W <br />\NMENNEENEEM <br />O <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />GARAGE ENTRY FORM DETAIL <br />�8x8x16 C.M.U. GARAGE DOOR <br />GARAGE DOOR ROLLER _ <br />CONNECTION ASSEMBLY <br />`,. GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />-TRACK MOUNTING BRACKET <br />GARAGE DOOR TRACK <br />SCALE: N.T.S. a , <br />a <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />2x CRIPPLES @ <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1 /2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 900 HOOK IN K.O. BLOCK <br />R L AM <br />VE TICA J ALT. KNEEWALL ABOVE MASONRY WALL DETAIL E <br />.x - A - -/ -/ V GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. SCALE: N.T.S. S4 <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />WALL PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />d a THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />d ° DOOR STOP PSPN516Z w/ (12)16d NAILS <br />d MOLDING TOP 2 ROWS 10d @ 3" O.C. (14 <br />2 x 6 P.T. o GARAGE SPLICE NAILS TOTAL) EA. SIDE OF <br />DOOR 48°SPLICE STAGGERED <br />J-BOLT <br />TRACK <br />BRACKET <br />vvvnrnnvn <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />1 (2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER • EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 wl (6)10d x 1 1/2" EACH <br />SIDE <br />2x STUDS TYP. <br />00 SIMPSON HTT4 TYP. <br />Op OR U.N.O. SEE N/S4 <br />F�/NC ** HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL Q <br />SCALE: N.T.S. SQ <br />-10d @ 8" O/C <br />ATTACH ALL -' <br />EXTERIOR STUDS <br />W/ (4) 16d TOENAILS <br />TO TOP PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. S4 <br />F= 2240 LBS <br />SIMPSON SIMPSON SIMPSON C <br />SP4 SP2 SIMPSON SP4 SP2 <br />2X STUDS @ 24" O.C. <br />/8"x10"'J." BOLT <br />@ 24" O.C. MAX. <br />MIN. (2) PER <br />BOTTOM PLATE <br />SECTION 2X P.T. <br />AZ PLATE <br />SIMPSON SP4 <br />EO <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />4 <br />°° a <br />INTO <br />- <br />TRANSOM <br />TRANSOM FRAMING <br />FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />SIMPSON <br />SP1 <br />SIMPSON <br />SIMPSC <br />RECESS <br />SP4 <br />SP4 <br />° <br />SIMPSON SIMPSON <br />SP4 SP2 <br />167 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />Sp1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />TRUSS BOTTOM CHORD OR 2x4 <br />W/ 2-16d TOE NAILS <br />IBLOCKING <br />@ EACH END <br />w <br />2x TOP PLATE <br />CC <br />6co <br />V2-16d <br />NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />FSTAGGERED <br />FROM BOT. <br />SEE A/S3 FOR <br />REINF. INFO. <br />PLATE TO CONCRETE <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />°o ° • HTT4 w/ (18)10d NAILS (3610# SPF) <br />° e • HTT5 w/ (26)10d NAILS (4670# SPF) <br />° ° • DTT2Z w/ (8)1/4" x 1 1/2" SDS (1835# SPF) <br />° o ° • HDU2-SDS2.5 w/ (6)1/4" x 21/2" SDS (2215# SPF) <br />° ° • HDU4-SDS2.5 w/ (10)1/4" x 21/2" SDS (3285# SPF) <br />_ • HDU5-SDS2.5 w/ (14)1/4" x 21/2" SDS (4065# SPF) <br />• HDU8-SDS2.5 w/ (20)1/4" x 21/2" SDS (5665# SPF) <br />• HDU11-SDS2.5 w/ (30)1/4" x 21/2" SDS (6865# SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT w/ WASHER & NUT <br />p • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT w/ WASHER & <br />NUT <br />• FOR HDU8 USE 7l8" DIA. x 12" EPDXIED A.T.R. <br />MIN, 8" EMBEDMENT w/ WASHER & NUT <br />• FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />HTT / HDU TENSION TIE rN <br />SCALE: NTS S4 <br />SIMPSON SP4 <br />�2X <br />TOP PLATE <br />OVERLAPPING <br />—10d NAILS @ 6" <br />STAGGERED <br />io I <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />° r r <br />2X8 P.T. BOTTOM P TE <br />5/8"xl0" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />" <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"xl0" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />`-(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />• <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />C <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGERED <br />TRANSOM FRAMING <br />o o BEYOND. <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" 0/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />o <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) o SHEATHING <br />• SIMPSON SP2 w/ (12)10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10)10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY l R <br />SCALE: N.T.S. <br />Ou <br />U <br />0 <br />z�_ <br />z <br />z <br />Q <br />a <br />z <br />U) t/') Ut <br />C1 <br />w <br />is p <br />•V w <br />0 <br />U <br />Mo <br />m cm <br />1..0 <br />O M <br />= <br />U <br />o -9 <br />tU.8 <br />Q <br />�� <br />o <br />B D. <br />" i <br />iU{p <br />T <br />N �D <br />,N. <br />� V�1 N <br />ZNZ � z <br />M <br />LL <br />LU <br />Q Lu <br />-Semu <br />Z 0 <br />U)•tfnmt`r�ff <br />•o' c Cc, <br />44 <br />SE1i <br />r.0 '••• •..' <br />?7FESS\ <br />�f�F``f��fftd!It6t��tt <br />��S <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />1a <br />a <br />U <br />K J <br />6W a <br />CE <br />C O <br />LL <br />I{�u �. N <br />F <br />L <br />N <br />M <br />Z 8 <br />' <br />y3 <br />() <br />"a <br />�/� <br />Y I <br />O <br />U <br />= <br />r" <br />�f <br />" OZ <br />Q <br />H6 <br />M <br />tj <br />U° �a <br />I <br />< <br />� <br />a o <br />J <br />Lr) <br />LLJ <br />Z <br />W <br />Q <br />zg <br />a U <br />Z$ <br />l00 <br />rn <br />c, <br />g <br />= <br />w <br />?-i <br />0- <br />cn <br />S <br />SCALE : AS NOTED <br />DATE : 08/08/2019 <br />TECH: FM <br />VERSION N0. 3ol <br />SHEET NO. <br />S4 <br />