My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
1551 (TPA) Hidden River
Zephyrhills
>
Building Department
>
Building Plans
>
1551 (TPA) Hidden River
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 2:28:39 PM
Creation date
2/28/2025 11:05:59 AM
Metadata
Fields
Template:
Building Plans
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />001 Fo <br />T.O.M. <br />HGT. <br />F.FL. <br />18' RIDGE VENT <br />12 <br />5� <br />6'-0"--------------- <br />4' RIDGE VENT <br />12 <br />�5 <br />--EXTENDED ------- <br />OVERHANG TO BE <br />CENTERED ON DOOR <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />--------------------- <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />T.O.M. <br />TEXTURED 1-0 <br />CEMENTITIOUS <br />FIN. ON C.M.U. <br />�— TEXTURED <br />(TYP.) <br />2'-0" <br />b <br />CEMENTITIOUS 10 <br />FINISH ON C.M.U. <br />2" x 4" SMOOTH <br />(TYP.) <br />TEXTURED <br />SILL / BAND <br />F.FL. <br />REAR ELEVATION - 61 <br />SCALE: 1 /4"=1'-0" <br />RIGHT ELEVATION - B1 <br />"=1 r <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or comice vents. <br />""CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN"" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. <br />0 <br />O <br />zo <br />z� <br />z� <br />Q <br />a <br />to (9 <br />0 <br />a) <br />N <br />4--J w <br />� p <br />�V — <br />O w <br />=D <br />� <br />o <br />M <br />U <br />® <br />m N <br />c <br />U <br />LL Cc <br />Q rn <br />Ln <br />rn o <br />B Ds <br />"V <br />• <br />t0 � <br />Z LU �' z <br />U) I- :'.- <br />= , § "-a- <br />d ,U_ aW <br />WaN <br />oclizm' <br />� 9 <br />�N' <br />www. ❑ <br />J _ <br />O� <br />z <br />�OCD <br />Q <br />4\ <br />s <br />O <br />Y• <br />\\\ <br />V//f R O F E S S'O%\``�� <br />f�'f//11llliltit�\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />z¢ <br />a <br />z <br />O <br />z <br />oo U <br />Z <br />z <br />W <br />�-� <br />Q <br />rz ® <br />L <br />`C1 <br />_1U <br />W <br />1 <br />Liu <br />Z <br />X <br />W <br />C1� <br />Ov <br />zLu <br />UA <br />o0o <br />HS <br />0 <br />w <br />o � <br />L <br />LU <br />z� <br />J <br />Ln <br />W <br />¢ � <br />Ln <br />L <br />Q <br />� <br />z <br />R1J.I <br />� 8 <br />r� <br />L!') <br />Z <br />= <br />W <br />f <br />SCALE : AS NOTED <br />DATE : 08/08/2019 <br />TECH: FM <br />VERSION NO. 3ol <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.