Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA <br />00 AMP 1 <br />200 A10 #12 copper to 20 amp clas <br />10 #10-2 copper to WH <br />01 e103 copper to Dryer <br />METER <br />n r /0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centedine above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />06 <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q� <br />11 <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />1-9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />I0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />_Q <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C`!'2 <br />ROUGH -IN FOR OPT. CEILING FAN <br />C\12 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />lip <br />VERIFY LOCATION "'.'IRRIGATION <br />ELECTRICAL PANEL <br />toOWA■IN am, F <br />rMI <br />1LEM.Mi Jill, 2 CAR GARAGE ill's - • • - 111[lion <br />•- <br />T. till <br />• �1►��� = <br />�� ' - ' - <br />■ ■��i1■_ _ GFI <br />DOOR <br />102111 065■ <br />i ■ 111►�■■�■IIif• <br />W w €==� <br />Is <br />�r. _ <br />• • _■■�� <br />swwwwwwwwwwwwwwwwwww _ ; ::.wwwwwwwwwwwwwwwwww = <br />• 111 O 111 ■■F.� �► <br />• • • • ■■Soo <br />Illr��— <br />„. __ ��ir■■I� <br />GFI ■■n� � � III 111 _ - �■�■ I-�wl <br />IIIIIIIIIIIIIIIIIIIII <br />QI wr:-.wwwwwwwwwww, w � f1♦�f1♦f1■ <br />� � I II 'I' - • II II <br />_ ® • . - <br />• Ali.BEDROOM <br />FOR _ ARM -. • - <br />AL <br />OPT. CLG. FAN/ BEDROOM 2 <br />FOR <br />DISC. LIGHT PRE-WIR'l <br />No MAh PRO <br />WP <br />GFI VP <br />EP)AD <br />H.B. <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4'=1'-0" <br />O u <br />O <br />Cn <br />Z <br />Z <br />Z <br />Q <br />d <br />Z <br />4--J rn <br />w <br />�o <br />0 w <br />YZCU ~ U <br />w <br />r- <br />mN <br />c� <br />�.- <br />_ <br />so - <br />0 00 <br />U <br />ru_co <br />B D. <br />=J, <br />N �O <br />p� <br />O � h 00 <br />U Z <br />5" <br />w <br />ED ' 0. <br />IoW—<cLL a <br />V 4�°'Q <br />Z <br />_ H � � <br />LLZa��' Q <br />INN¢� <br />WWW.FDSENG.COM 13 <br />rn <br />o <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings empty with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />za <br />z <br />ti <br />dw <br />J <br />W <br />pg$ <br />8 <br />a <br />UEE <br />al <br />w <br />Z <br />J <br />X <br />Lr) <br />W <br />Cr <br />U <br />O <br />O <br />J <br />u- <br />�W <br />� Z <br />Ro <br />g <br />fig <br />o <br />z <br />I�06 <br />TF <br />S <br />L <br />{J! Z <br />l7 W g <br />a <br />0 <br />Z <br />LU <br />V-4 <br />Ln <br />tJ.l <br />Z <br />. . <br />l.0 <br />X <br />Z <br />dz8 <br />~'Wa <br />$g <br />rl <br />In <br />Z <br />U <br />m <br />0 <br />6 <br />LU <br />� <br />W <br />g <br />o <br />SCALE : AS NOTED <br />DATE : 08/08/2019 <br />TECH: FM <br />VERSION NO. 3ol <br />SHEET NO. <br />4.0 <br />