Laserfiche WebLink
SIMPSON HGAM11 <br />wl <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (j <br />1/4"x2 3/4" <br />TITEN TO CMU <br />SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS BACKNAIL w/ (2)16d NAILS SIMPSON H10A w/ (18) SIMPSON SP4 w/ <br />TOENAIL W/ (2) 16d NAILS SIMPSON H10A w! (18) (6)10d x <br />NAILING SCHEDULE FOR 2"x4" 1 Od x 1 12" AT EA. 1 12" AT EA STUD USE BACKNAIL w/ 2 16d NAILS SIMPSON H1 OA w! 18 <br />2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. SEE STRUCTURAL NOTES ( () ( ) <br />SHEATHING DETAIL „ OUTLOOKER OUTLOOKER SPA COD') 6 WALL USE " <br />TOP CHORDOR <br />a@ 24 O.C. <br />NAILING SCHEDULE FOR OU I LOOKER <br />AND NAILING SCHEDULE <br />@ 24" O.C. FOR SHEATHING DETAIL <br />SHEATHING DETAIL <br />BLOCKING F <br />• <br />FIRST FOUR <br />ROWS OF <br />45° t <br />24" MAX. <br />TOP CORD BLOCKING <br />45°t <br />2X4 CONT'L" BRACE <br />TOP CORD BLOCKING <br />TRUSSES @ <br />SIMPSON H10A w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)1 Od 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF 2x4 CRO BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24"O/C. CMID HEIGHT <br />OF TRUSSES @ EDGES <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />OF SHEATHING TYPICAL <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. <br />2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />• <br />48" O.C. EACH JOINT W/ (3) 1Od <br />YAT LEAST 90% OF WEB <br />@ 8'-0" 0/C. <br />EXTEND AT LEAST 90% OF <br />, <br />MAX. & (2)10d TOE NAILS @ <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />J <br />2x6 P.T. GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />• <br />SILL 1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />: <br />7/16" OSB SHEATHING <br />& (2)1Od TOE NAILS @ <br />BLOCKING <br />ATTACHED W/ 10d <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1 OdX3" @ 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />1/2" CDX PLYWOOD OR 7/16" <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />OSB SHEATHING ATTACHED <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ 10d NAILS @ 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4 "T" ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />MOISTURE BARRIER <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />BOTTOM ATTACHED w/ (2 <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)10dxl 1/2" NAILS AT 6'4" <br />INSTALLED PER MANUF. <br />16d TOENAILS <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />1 Odx1 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)1Od NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4)1/4"x21/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION <br />O.C. MAX) w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />1Od NAILS & (4)1/4"x21/4" SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />S5 <br />TITEN ON OUTSIDE <br />BACKNAIL W/ 2 16d NAILS SIMPSON H1 OA w/ (18) <br />A <br />SP8 FOR 2x8 WALL) <br />SEE STRUCTURAL NOTES 10d x 1 12 Al EA. <br />OUTLOOKER <br />AND NAILING SCHEDULE <br />7 <br />2x4 OUTLOOKER <br />FOR SHEATHIN <br />DETAIL <br />@ 24" O/C <br />2x4 OUTLOOKER @ 24" <br />TOP CORD <br />4" MAX. <br />O.C. (OPTIONAL - SEE <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4"CROSS BRACE <br />24" MAX. <br />EDGES OF <br />FROM RIDGE FASTENED AT <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />EACH JOINT W/ (2)10d & (2) 10d <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />TOE NAILS @ EA. END <br />EACH JOINT W/ (2) <br />; <br />AT LEAST 90% OF WEB <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2) 16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAILS <br />ATTACHED w/ 10d NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />@ 6" O.C. EDGES AND 12" <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />O.C. FIELD <br />(2)16d NAILS <br />BOTTOM ATTACHED <br />48" <br />2x BLOCKING <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />M <br />2x4'T' ON TOP OF PANEL <br />10dx3" @ 4" 0/C <br />BLOCKING, FASTEN WITH <br />SIMPSON HGAI OKT w/ (4)1/4"x1 1/2" <br />1Odx3" @ 4" O/C <br />SDS SCREWS TO TRUSS & (4)1/4"4" <br />SDS SCREWS TO PLATES AT 36" O.C. <br />SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />DBL. TOP PLATE <br />CHORD SLOPE OF ADJACENT TRUSS) STUD WALL SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />( ) <br />1 Od x 1 12" AT EA. 2x4 OUTLOOKER <br />REFER TO DETAIL J <br />r <br />SEE STRUCTURAL <br />OUTLOOKER F@ 24" O/C <br />ON SHEET S5 FOR <br />X-BRACING, AND TOP <br />" <br />" <br />x <br />NOTES AND NAILING <br />TOP CORD <br />CHORD BLOCKING <br />N <br />;0o0 <br />SCHEDULE FOR <br />BLOCKING FOR <br />INFORMATION <br />`° <br />SHEATHING DETAIL <br />FIRST FOUR ROWS <br />OF TRUSSES @ <br />1 <br />ill <br />1/ " <br />2"x4"CROSS BRACE <br />24"'MAX. <br />EDGES OF <br />• WOOD TRUSSES <br />�° <br />;� <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />RIDGE FASTENED AT <br />L BRACE TO EXTEND <br />-2x4 RAT RUN BRACING <br />JOINT W/ (2) <br />AT LEAST 90% OF WEB <br />AT 24" O.C. ON TOP OF <br />L2'EACH <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 <br />TRUSS SPANS <br />NAILS @ EA. END <br />GABLE TRUSS <br />ATTACHED W/ 2 -16d <br />`7 Q` <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT <br />!_ll <br />@ 48" FOR THE <br />(2) 16d NAILS <br />OSB SHEATHING ATTACHED <br />/_W/ <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 6" LAMINATIONS W/ (2) ROWS OF <br />(4) FIRST (4) ROWS OF <br />10d NAILS @ 6" O.C. <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS <br />STAGGERED 30d COMMON WIRE NAILS <br />TRUSSES FROM EA. <br />E <br />ES AND 12" O.C. FIELD <br />- 2x4 BLOCKING @ 24" <br />O/C w/ (2) 16d <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />END TYP. TOP & <br />JACK TRUSS <br />TOENAILS EA END <br />NOTES: <br />BOTTOM ATTACHED <br />SEE PLAN FOR <br />@ 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL w/ (2)16d TOENAILS <br />IASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) i <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL 2x4'T' ON TOP OF PANEL <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCKING, FASTEN WITH 2x4 BLOCKING W/ - . <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d A) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION 10dx3" @ 4" O/C (2)12d TOENAILS _ . <br />EXT. WALL CONN. @ COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF ' <br />NON -LOAD BEARING LOCATION B.U.C., SAME NUMBER OF ROWS, SAME SPACING) ) 8 SECTION g <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"= V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS <br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)1 Od PER JOINT <br />IINIMUM 2x OVERLAP TRUSS BRACING <br />,ROSS BRACING _ PRE-ENGINEERED AT LEAST TWO TRUSS SPACES 6" OVERLAP <br />SEE PLAN FOR WOOD TRUSSES <br />OCATIONS) 1 Odx3" O/C @ 2"x4" <br />TOENAIL 6" O/C RUNNERS <br />W/ (2)16d TYPICAL <br />(2)16d PER NAILS <br />JOINT <br />L CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL J <br />SCALE: N.T.S. S5 <br />ALTERNATE NON -DROP I I I I I I <br />GABLE END DETAIL MINIMUM (2)16d PER JOINT MINIMUM 2x4 TRUSS BRACING SCALE: N.T.S. TRUSS BRACING OVERLAP DETAIL /�M <br />1 GABLE TRUSS <br />"L" BRACE W/ 1 Od @ 4" O.C. <br />12 (SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />6.9 MAX. <br />S5 <br />GABLE END BRACING DETAIL <br />6M <br />CONT. BEARING <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />SCALE: N.T.S. \, S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)1Od <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />Z <br />w <br />BRACING w/ (3)10d x 3" AT <br />EACH CONN. @ 24" O/C <br />SIMPSON HGAMIOKTA w/ (4) MOISTURE BARRIER <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />MASONRY WALL <br />,2x4 BLOCKING 2x4'7" BLOCKING <br />@ 48" O.C. 16d NAIL <br />L BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 7" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 1Od NAILS @ 4" 0.C— <br />TYPICAL <br />GABLE TRUSS WEB � <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0!C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE -� <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 n 1- CONTINUOUS SOTTO CHORD BRACING 2X4 MIN. <br />�r�IIY��I�11I <br />� <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. NON -LOAD <br />BEARING LOCATIO (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />74" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-0" <br />T-0" - V-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"xl 1/7 SDS <br />SCREWS TO TRUSS & (4)1/4"x3" SDS SCREWS <br />TO PLATES (TYP.) <br />I- r -GABLE TRUSS <br />-STUDS @ 16" O.C. <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />11'-0" MAX. <br />�q <br />CORNERJACK <br />0 <br />Y <br />a <br />Q <br />w <br />Z <br />0 <br />HIP FRAMING REFERENCE PLAN <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) 7' BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />LTOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />zo <br />Z C> <br />z� <br />a <br />Cn C9 <br />4--Jw <br />C6 0 <br />•p w <br />ITU <br />U <br />LU <br />mn <br />04 <br />_ <br />m " <br />L " <br />o 'o 0 <br />U <br />t`L00 <br />¢m <br />C3�C> <br />�Q d <br />BD. <br />NC� <br />Noz r z <br />ED <br />LU "- <br />Z O ¢NM 0 2 <br />x <br />ca g <br />Z HM2� <br />UM Q N Q M Gi <br />LU <br />� ,��!`@ttI�El�fppp6 <br /><� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />o <br />cc <br />U, o <br />za <br />Q <br />�?V�U <br />U <br />8 <br />OC J <br />O <br />U121 <br />L <br />g <br />N <br />> <br />CJ7 <br />— <br />U <br />Z <br />Z <br />CLc <br />L <br />}N <br />'v <br />Z <br />U <br />V <br />V <br />Z <br />W <br />o <br />0 <br />v, <br />a� <br />U0 <br />r-4 <br />�••� <br />� <br />llltgtgtqQ <br />Z <br />LLI J <br />Ln <br />Q <br />Z <br />Lj <br />Z <br />Q <br />u�Z <br />a <br />s <br />cV <br />*k <br />LLn <br />0 <br />O� <br />g <br />= <br />¢� <br />SCALE : AS NOTED <br />DATE : 08/07/2019 <br />TECH: FM <br />VERSION N0. 4mO <br />SHEET NO. <br />S5 <br />