Laserfiche WebLink
0 <br />Zo <br />' OFFRIDGE VENT 4' OFFRIDGE <br />12 = - -- - 12 <br />�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />EXTENDED <br />OVERHANG TO BE <br />CENTERED ON DOOR <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />REAR ELEVATION — B1 <br />4' RIDGE VENT <br />SCALE: 1 /4"= V-0" <br />--------- T.O.M. <br />— — — — HDR <br />F. FL. <br />0 <br />iio <br />HDR HGT. <br />1'-0" <br />TEXTURED <br />CEMENTITIOUS 2 -0 <br />TEXTURED ol <br />FINISH ON C.M.U. <br />CEIVIENTITUS <br />C? (TYP.) FINISH ONICO.M U. <br />(TYP.) <br />F.FL.- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ---------- <br />RIGHT ELEVATION — B1 <br />SCALE: 1 /4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />cv <br />.J Off . <br />o <br />� <br />u. <br />U �� <br />OFESJXO�P� <br />\\\ <br />11l�`����\\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />co <br />v E co <br />a cO 8 N N # <br />J <br />r it LL <br />Q y 3t <br />91 J W <br />- � 'O LL J d <br />u_ <br />fii Qj M M W In <br />air <br />t9 ='ate z o <br />13 <br />�Z a c W E- <br />00 <br />to� <br />mo <br />ON G m <br />Wo00 <br />2) rn <br />W <br />0ow ZIrN <br />CN N U �a <br />LL <br />13 <br />v ❑❑❑ <br />Z 0CD <br />z <br />z $ <br />< <br />Q �a <br />M <br />� z <br />cc <br />CD <br />�--+ cn <br />w � <br />Jm <br />0On <br />N = .. <br />U c <br />r _ pEp <br />I <br />• <br />sm <br />Cn <br />w <br />co <br />M <br />o m <br />z <br />4 <br />U_ <br />— <br />o o <br />s <br />QE <br />C OU <br />_® <br />Da <br />(O <br />�OV <br />a ¢ <br />�O <br />O <br />O <br />N <br />a p <br />W z <br />z <br />N i <br />wo <br />¢o <br />¢ <br />mf <br />n3 <br />Cn <br />a�z <br />o� <br />�m <br />O <br />z <br />Z <br />J <br />0 <br />YZ <br />zz <br />N <br />0 <br />p <br />dW <br />o� <br />¢¢ <br />O <br />d r <br />O <br />VO <br />zl< <br />3 <br />c <br />0 <br />>M <br />J <br />^L1 <br />� <br />m <br />W <br />'— <br />m <br />M <br />Q <br />C:) <br />rl <br />m = <br />� <br />T <br />T�ue 0 04 O <br />Cy) <br />L0 <br />._ >N N <br />J <br />r <br />T � <br />T <br />T <br />co (N r <br />r <br />00 <br />CV <br />T <br />o <br />Z <br />cc <br />Z <br />E O <br />tL <br />a <br />U � Q p <br />c <br />JOB NO: 20-8069 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.2 <br />l <br />