My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2831 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2831 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:26:10 AM
Creation date
2/28/2025 11:03:14 AM
Metadata
Fields
Template:
Building Plans
Street #
2831
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
1025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIMPSON HGAM11 <br />W/ <br />(4) 1/4"xl 1/2" SDS <br />SCREWS <br />TO BLOCKING & (� <br />1 /4"x2 3/4" <br />TITEN TO CMU <br />SEE STRUCTURAL NOTES AND TOENAIL W/ (2) 16d NAILS BACKNAIL W/ (2) 16d NAILS SIMPSON H10A w/ (18) BACKNAIL w/ (2)16d NAILS SIMPSON H1OA w/ (18) SIMPSON SP4 w/ (6)10d x <br />NAILING SCHEDULE FOR 2"x4" 1 Od x 1 12" AT EA. 1 12" AT EA STUD USE BACKNAIL w/ 2 16d NAILS SIMPSON H10A w/ 18 <br />2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. SEE STRUCTURAL NOTES I () e ( ) <br />SHEATHING DETAIL OUTLOOKER OUTLOOKER SP6 FOR 2 6 WALL USE <br />TOP CHORD <br />BLOCKING FOR <br />@ 24" O.C. <br />NAILING SCHEDULE FOR OUTLOOKER <br />SHEATHING DETAIL <br />TOP CORD BLOCKING 45°t <br />AND NAILING SCHEDULE <br />@ 24" O.C. FOR SHEATHING <br />2X4 CONT'L" BRACE <br />DETAIL <br />TOP CORD BLOCKING <br />FIRST FOUR „ <br />ROWS OF 45° t 24 MAX. <br />TRUSSES @ <br />SIMPSON H10A w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)10d 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF 2x4 CRO BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" O/C. CMID HEIGHT <br />OF TRUSSES @ EDGES <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />OF SHEATHING TYPICAL <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. 2X4 KICKER <br />2x8 "L" BRACE TO <br />48" O.C. EACH JOINT W/ (3) 10d <br />MAX. & (2)EN TOE NAILS @ <br />AT LEAST 90% OF WEB <br />2x4 CROSS BRACE @ 8'-0" 0/C. <br />END A <br />EXTEND AT LEAST 90% OF <br />WEB LENGTH & NOTCH AT <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX, 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />2x6 P.T. <br />GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) Sd <br />SILL <br />1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />; <br />7/16" OSB SHEATHING <br />& (2)10d TOE NAILS @ <br />BLOCKING <br />ATTACHED W/ 10d <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1 OdX3" @ 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />7 <br />1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />tt <br />THROUGH CHORD <br />CORD ATTACHED W! (2)16d TOENAILS <br />10d NAILS 6" O.C. <br />w/ @ <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4 'IT" ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />MOISTURE BARRIER <br />BOTTOM ATTACHED w/ (2 <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)10dx1 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />16d TOENAILS <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />1Odxl 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)1 Od NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4)1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION <br />1 <br />O.C. MAX) w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />S5 <br />TITEN ON OUTSIDE <br />SIMPSON H10A <br />w/ (18) <br />BACKNAIL W/ (2)16d NAILS <br />A <br />SEE STRUCTURAL <br />NOTES 10d x 1 12 AT EA. <br />SP8 FOR 2x8 WALL) <br />AND NAILING SCHEDULE <br />OUTLOOKER 2x4 OUTLOOKER <br />FOR SHEATHIN <br />DETAIL F@ 24" O/C <br />2x4 OUTLOOKER @ 24" <br />TOP CORD <br />O.C. (OPTIONAL -SEE <br />4" MAX. <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4" CROSS BRACE <br />24" MAX. EDGES OF <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />EACH JOINT W/ (2) 10d & (2) 10d <br />EACH JOINT W/ (2) <br />; AT LEAST 90% OF WEB <br />TOE NAILS @ EA. END <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />K7116" <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2) 16d OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAILS ATTACHED w/ 1Od NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />@ 6" O.C. EDGES AND 12" <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />O.C. FIELD <br />(2)16d NAILS <br />BOTTOM ATTACHED <br />48" 2x BLOCKING <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />M Ak 2x4 'IT" ON TOP OF PANEL <br />SIMPSON <br />HGAIOKT wl (4)1/4"xl 1/2" 10dx3" @ 4" 0/C <br />BLOCKING, FASTEN WITH <br />SDS SCREWS <br />TO TRUSS & (4)1/4"x3" <br />1Odx3" @ 4" O/C <br />SDS SCREWS <br />TO PLATES AT 36" O.C. SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />CHORD SLOPE OF ADJACENT DBL. TOP PLATE <br />TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />1 Od x 1 12" AT EA. <br />2x4 OUTLOOKER <br />REFER TO DETAIL J <br />SEE STRUCTURAL <br />OUTLOOKER <br />@ 24" O/C <br />ON SHEET S5 FOR <br />r <br />NOTES AND NAILING <br />TOP CORD <br />X-BRACING, AND TOP <br />N <br />SCHEDULE FOR <br />BLOCKING FOR <br />CHORD BLOCKING <br />`° <br />� <br />°° <br />SHEATHING DETAIL <br />FIRST FOUR ROWS <br />INFORMATION <br />OF TRUSSES @ <br />1 1 l <br />21/ <br />BRACESS <br />24" MAX. <br />EDGES OF <br />-WOOD TRUSSES <br />APPROX. 8' FROM <br />SHEATHING TYP. <br />RIDGE FASTENED AT <br />ZAZ <br />"L" BRACE TO EXTEND <br />-2x4 RAT RUN BRACING <br />$123' <br />EACH JOINT W/ (2) <br />; <br />AT LEAST 90% OF WEB <br />AT 24" O.C. ON TOP OF <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 <br />NAILS @ EA. END <br />GABLE TRUSS <br />TRUSS SPANS <br />ATTACHED W/ 2 -16dOSB <br />/� <br />`►l <br />2x4 PANEL BLOCKING <br />1/2"CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT <br />� <br />@ 48" FOR THE <br />(2) 16d NAILS <br />SHEATHING ATTACHED <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2 x 6 LAMINATIONS W/ (2) ROWS OF <br />(4)O/C <br />FIRST (4) ROWS OF <br />W/ 10d NAILS @ 6" O.C. <br />W/ 1 <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS <br />TRUSSES FROM EA. <br />E <br />ES AND 12" O.C. FIELD <br />-2x4 BLOCKING @ 24" <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL <br />END TYP. TOP & <br />JACK TRUSS <br />O/C w/ (2) 16d <br />TOENAILS @ EA. END <br />NOTES: <br />BOTTOM ATTACHED <br />SEE PLAN FOR <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL <br />w/ (2)16d TOENAILS <br />CONNECTION <br />MASONRY WALL <br />OF THE COLUMN <br />(SPACE AS SHOWN FOR 3-PLY) <br />-ARCHITECTURAL FINISH <br />2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />2x47' ON TOP OF PANEL <br />\\� <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCKING, FASTEN WITH 2x4 BLOCKING W/ ! .° <br />1 Odx3" @ 4" O/C (2)12d TOENAILS <br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION 71 <br />COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />NON — LOAD BEARING LOCATION rD B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION g <br />SEE TYP. WALL SECTION FOR SCALE: 3/4" = V-0" TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS r <br />ADDITIONAL INFORMATION. `S5 <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)1 Od PER JOINT <br />!INIMUM 2x <br />'ROSS BRACING <br />3EE PLAN FOR <br />OCATIONS) J1063" O/C <br />TOENAIL 6" O/C <br />W/ (2)16d TYPICAL <br />(2)16d PER NAILS <br />JOINT <br />L- CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL rj� <br />2"x4"y <br />RUNNE <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />SCALE: N.T.S. SJ <br />1 GABLE TRUSS <br />S� <br />"L" BRACE W/ 10d @ 4" O.C. <br />12 (SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />6.9 MAX. <br />S5 <br />GABLE END BRACING DETAIL <br />S5 <br />CONT. BEARING <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />SCALE: N.T.S. S'J <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES 6" OVERLAP <br />MINIMUM (2)16d PER JOINT `- MINIMUM 2x4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL M <br />SCALE: N.T.S. S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)1 Od <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />124" O/C (TYP) <br />I v / _N " " ' 0 <br />z <br />w <br />\_BRACINGw/(3)10dx3"AT EE <br />• EACH CONN. @ 24" O/C <br />SIMPSON HGAMIOKTA w/ (4) MOISTURE BARRIER <br />1/4"xl 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />ut--- MASONRY WALL <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4'T' BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 1Od NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB —' <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE J <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE 'IT" BRACEr7 <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 I CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. NON — LOAD <br />BEARING LOCATIO (UNEVEN CLG.) E <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5 <br />ADDITIONAL INFORMATION. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-O" <br />3'-0" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"x1 1/2" SDS <br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS <br />TO PLATES (TYP.) <br />i—GABLE TRUSS <br />`STUDS @ 16" O.C. <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />o <br />ac <br />0 <br />� <br />i <br />CORNER JACK <br />Y <br />U <br />tY <br />w <br />z <br />M <br />O <br />U <br />HIP FRAMING REFERENCE PLAN <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) 7' BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 SCALE: N.T.S. <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />LTOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />tstttt�!tf{ftOfPtr <br />fr! <br />0WN <br />-- (j <br />�l <br />✓ <br />^ <br />•,� <br />MPS 1, �"' S 1 % c it <br />�. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages hearing <br />Engineers signature and seal. <br />IN <br />Q <br />o EE p'-p <br />0 8 a N iY <br />0 <br />y C� m # 0 LL <br />rn <br />to <br />uj a <br />U) � a u . <br />Q <br />Z <br />°jMM W <br />a Lu <br />'zWo <br />To�C <br />oc_p mm O <br />W <br />C/5 � <br />LL = <br />00 NO X ay <br />N ch Z V 0 J <br />OU <br />Z <br />W <br />C <br />Z N M <br />z c' <br />Q <br />wad <br />4-1 <br />N <br />w <br />� A <br />V <br />0 <br />w s <br />N <br />� N <br />U c <br />� E <br />� <br />c <br />Q 00 0 <br />�0 <br />see <br />w <br />Cl) <br />o <br />Z <br />Q E <br />0 <br />zoo <br />�1 w° <br />� <br />�® <br />oa <br />co <br />o <br />Zo� <br />C <br />X U <br />o< <br />°dz <br />oa <br />�z <br />az <br />N <br />o <br />¢o <br />t <br />w0 <br />c <br />ox <br />oz <br />Z, <br />z <br />(3)< <br />W <br />a" <br />g0 <br />�o <br />a <br />w <br />W <br />T <br />0. <br />Z <br />w� <br />' F <br />o <br />cio <br />za <br />>° <br />a <br />�3 <br />2M <br />0 <br />= <br />0 <br />> <br />� <br />^�1 <br />m <br />0 <br />.� <br />O <br />(3) <br />T <br />_ <br />Q <br />C 0 <br />0 <br />o <br />�i <br />N <br />O <br />N <br />� <br />J <br />LO <br />oo <br />E <br />N <br />T <br />i� <br />N <br />o <br />Z <br />Z <br />:3 <br />E O <br />6i <br />N <br />2 <br />E <br />U J <br />Q 0 <br />J <br />JOB <br />NO: <br />20-6579 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.