r I I _ 11_._1_' 11 1 1 1 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />10 N 14 cropper to Nghts & outlets <br />NEMA 1 11 p 12 Copper to 20 amp ckts <br />200 AMP <br />10 k10-2 copper to WH <br />11 d10-3 copper to Dryer <br />METER <br />MAIN T <br />0 r 2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED---. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 -53 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />tom' <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />GIN <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />—� <br />TRACK LIGHT <br />��- <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />r0 <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />1 P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />InA <br />OWNER'S SW� ITE <br />T <br />/ ROUGH -IN FOR / <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE / <br />u mn <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />AHU <br />FAMILY RM <br />/ <br />� i% <br />!i V <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />j <br />U.C. OUTLET <br />I <br />FOR DW <br />I <br />C.OUTLET � <br />I <br />69 <br />✓ \ <br />_ <br />�------- <br />—_—_ <br />—GFI <br />- <br />CAFE // <br />// <br />GFI <br />I <br />C—_----------- <br />r- <br />I \ <br />I I <br />GFI <br />- - -' - <br />D.W. <br />INNKK W// <br />Ulbs, � <br />C 1 I�J:C. SWITCH <br />T <br />/ <br />NDANT S <br />-, F0R�ISPQSAI . <br />PER SPECS <br />/ <br />--RANGE <br />/ <br />n <br />F\4fm <br />`I{' �_ DEDICATED RECEPTACLE <br />WID H.B. FOR MICROWAVE RANGE <br />GFI DISC. HOOD PER SPECS <br />-----------� <br />I <br />I <br />I <br />W.I.C. <br />I <br />I <br />� I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />----------- <br />I <br />OPT, <br />REF— BEDROOM 2 <br />GFI <br />OUGH-IN FOR <br />I OPT. CLG. FAN/ / <br />LIGHT PRE -WIRED <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />IRRIGATION <br />VERIFY LOCATION r GFI @ —4 4—" A.F.F. <br />Dw <br />ELECTRICAL PANEL <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOO� <br />GFI <br />GFI @ 44" <br />A.F.F. <br />I <br />I I <br />I <br />I fl I <br />I <br />I <br />\ — / L — — — — — — — — — — — — <br />GFI @ 44" <br />,N. A.F.F. <br />N\ <br />BEDRi'00M 31 <br />I <br />G RO H-IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />ENTRY <br />I I <br />I I <br />I I <br />I I <br />A <br />BEDROOM 4 <br />ROUGH -IN FOR <br />JM\` OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />f <br />Y \ <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />0 <br />CV <br />0 <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />rA <br />H <br />Q <br />E <br />88 <br />pp <br />Ni! <br />(% <br />m r C <br />•>�0 NFA <br />J <br />� iA U. <br />J iL W <br />0tn��Z2 <br />U. LL a <br />N I. il_ <br />a. a. <br />Li <br />�-p— <br />Cn L <br />Z O <br />mmg <br />W_ <br />C � <br />t p V <br />�) <br />LL <br />U <br />00 Cj <br />tto h Z <br />o a. <br />2 0 N <br />_ z <br />to <br />°U <br />U J <br />��D <br />W <br />V M <br />z Cl) <br />Z � N <br />z � � <br />' <br />N <br />z to <br />9 <br />0 <br />- <br />V <br />0 <br />w s <br />N <br />c <br />w <br />_ <br />M <br />I <br />Q <br />seo <br />C.0 <br />w <br />Ch <br />M <br />z � <br />O <br />Z <br />Q <br />U_ <br />E <br />E n- <br />z 0 <br />0 <br />�� <br />s <br />wz <br />� <br />} N <br />Q N <br />=_® <br />❑a <br />Z <br />I— <br />o E <br />N� <br />x0 <br />U� <br />a8 <br />� <br />ao <br />Ur; <br />oQ <br />aZ <br />� <br />o <br />�w <br />w <br />• ro <br />N C <br />� <br />" 2 <br />E <br />m o <br />oZ <br />Z <br />0J <br />J <br />m <br /><� <br />a w <br />ZZ <br />d 3 <br />a� <br />0M <br />0 <br />do <br />�w <br />W <br />0. <br />o <br />hLL <br />� <br /><< <br />3 <br />=r <br />�o <br />ila <br />0 <br />0 ,11 <br />� M <br />> d' <br />cc <br />m <br />W <br />/ <br />cc <br />c) <br />.— <br />O <br />L <br />O <br />Q <br />0 <br />o <br />a) m <br />CD <br />CL <br />0 NO <br />.�, <br />J N <br />r <br />T <br />I O <br />o <br />T- <br />M <br />T— <br />N <br />;� <br />o <br />z <br />z <br />E O <br />o <br />of <br />a <br />U <br />Q p <br />JOB <br />NO: <br />20-6579 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />