My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2834 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2834 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:31:53 AM
Creation date
2/28/2025 11:03:19 AM
Metadata
Fields
Template:
Building Plans
Street #
2834
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
1102
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />19.000000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />1 <br />561.0 <br />285.0 <br />276.0 <br />(Zone 1) <br />-NOTE- <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN - ELEV-Al <br />SCALE: %4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />`"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />f <br />:�S✓ Wi1j A,���tA `� <br />e. <br />{1�Z r <br />p's•A9D'a#�.. nab@• ®� <br />�� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />/W/ V EE <br />V 8 N it <br />toS (,-'-4 Lo <br />0 .5 � T N J* W <br />u <br />t,e 'C r6 WLLI <br />J LL a CL <br />— a c Z O <br />Z m e O F <br />y @o a m O <br />x C� CO <br />020, J o a <br />U)°° <br />N O a ❑ rn <br />L0 M <br />U O <br />N <br />Q <br />M � <br />N M <br />O <br />z <br />� <br />o <br />< <br />o n <br />QE3 <br />U) N <br />M <br />z <br />�-1 <br />vCD <br />u <br />U <br />O g <br />C" <br />� 1) <br />w. <br />U <br />W J <br />._ _. [-- E <br />i <br />z <br />U ) W <br />W Y <br />N m <br />S� <br />O <br />O <br />f <br />w <br />M <br />M <br />Zo <br />Z <br />Z¢ <br />U_ <br />Z <br />� O <br />i <br />@ <br />O <br />Z 0 <br />cu <br />U <br />O E <br />N <br />tip <br />ao <br />4o <br />aZ Z <br />wn <br />L <br />_ C <br />Y <br />�m <br />Z <br />N <br />J <br />a <br />Qw <br />1 Z <br />to <br />oa <br />g0 <br />Q � <br />wLL <br />�o <br />a <br />�w <br />�G <br />U <br />' <br />off <br />�Z <br />=3 <br />o <br />ZZ°Ia <br />¢ <br />0 3 <br />.L0 CN <br />_ <br />� <br />cc <br />0 <br />> <br />.� <br />cc <br />0 <br />LO <br />C U <br />1 m <br />/O� <br />= <br />"t <br />r <br />� 0 O <br />C� <br />T T <br />LO <br />r <br />I L.n M <br />r <br />oo CV <br />N <br />o <br />m <br />Z <br />� T coZ <br />E O of <br />`a <br />a <br />E <br />U _JJ <br />c <br />JOB <br />NO : 20-8071 <br />SCALE : AS NOTED <br />SHEET NO. <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.