My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2893 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2893 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:37:20 AM
Creation date
2/28/2025 11:03:25 AM
Metadata
Fields
Template:
Building Plans
Street #
2893
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
872
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I___ ! _I _. "_1. 1-1 I. � "fn.. I 1 L1 1 III t <br />_J_ <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />00 #I4 copper to lights & outlets <br />1 <br />200 10 #12 copper to 20 amp ckts <br />00 AMP <br />10 <br />#10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />M T <br />210 or 4/0 SER Alu <br />200 amp <br />150 amp IT <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER 71 <br />NEC 14, 250.94 —I <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />fa <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />_Q <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />GFI <br />H.B. <br />FOYER_ <br />CAFE <br />FAMILY ROOM <br />` 12 PENDANT AS <br />\ PER SPECS <br />`— — — — — — — — — — — CH AHU W.H. <br />ROUGH -IN FbR \ \ 7'-0" T <br />-,- - -- <br />\ OPT. CLG. FbN/ LIGHT <br />\ PRE -WIRE <br />1 - OPT. <br />D.PFI <br />W. - <br />I � \ <br />OW, R'S I <br />�lJ ITE <br />6 <br />' ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />H.B. <br />GF L_= --- J GFI <br />F VP <br />gjS.Dtlz I - - DW I "� .SINK w/r DISP <br />1 --- JpRD15fOS U.C. $WITCH <br />�. F <br />RANGE <br />-- GFI <br />GFI GFI <br />o DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE G <br />HOOD PER SPECS <br />W.I.C.--� <br />ROUGH -IN FOR <br />OPT. CLG. WN/ <br />LIGHT PREIWIRF <br />BEDF4OOM 2 <br />S.D <br />H) <br />I <br />_ ENTRY <br />I <br />WP " <br />,UGFI I <br />IRRIGATION <br />GFI @ 44" A.F.F. <br />I------------ <br />I- <br />Ik�� <br />II �I <br />I <br />II /l <br />I <br />I <br />I 1/ I <br />I <br />I <br />L_ 1r <br />I <br />I <br />�\ <br />I <br />I GARAGE <br />\ <br />GARAGE <br />DOOR <br />\ <br />LIGHT AS <br />I GFI <br />\ <br />PER SPEC <br />% <br />I <br />44" <br />\ <br />)-A.F.F.2- <br />R-GAR-A <br />� <br />I <br />Q <br />I <br />^Ua <br />I <br />J0U <br />I <br />}� <br />�U <br />I <br />I <br />Cr <br />wJ <br />I <br />W <br />GFI @ 44" <br />A A.F.F. <br />CS. <br />qP <br />I EDROOM 4 <br />�� � <br />ROUGH -IN FOR G , ROUGH -IN FOR <br />LIIGHT PRE-W REB E D �OO M 3 OPT. CLG. FAN/ <br />L <br />\ LIGHT PRE -WIRE <br />dC \ <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />0 <br />0 <br />N <br />N <br />0 <br />rn <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />H <br />a <br />E <br />go 88 <br />cO <br />NNit <br />C <br />y N <br />N <br />CDU- <br />fA <br />7 <br />U) <br />J W <br />. <br />uS; LLoO <br />MW <br />MLLILL <br />m0"0L <br />a W <br />CZ <br />X OQM m <br />�pjQ' (ncc)NZNCl)OLL <br />Nar°n <br />U <br />W <br />OcU❑00 <br />� <br />V M .�- <br />z N frl <br />o� <br />Z C N <br />z o � <br />Q <br />N <br />- N <br />z 9 <br />� o <br />� <br />LL <br />Cn <br />� a <br />i0 <br />V <br />0 <br />w g <br />Ly N <br />IN <br />L I <br />y <br />s <br />U Gi <br />wj <br />�LE <br />, <br />U o' a• <br />N <br />sm <br />ZM <br />M <br />i <br />O <br />Z <br />U_ <br />Q E <br />� <br />z o <br />o 0 <br />W z <br />Z 0 <br />Z <br />E u14 <br /><0 <br />�_ CL <br />o <br />o a <br />�0 <br />p` <br />a s <br /><o <br />_° <br />SZ <br />o Z <br />wZ <br />o � <br />IZ <br />ZN� <br />- <br />j <br />� J <br />Nm <br />�m <br />a w <br />�N <br />U)ti <br />Q� <br />�� <br />Z Z <br />go <br />�w <br />W <br />�= <br />aZ <br />�O <br />o <br />c0 <br />V <br />wa <br />is <br />a <br />°3 <br />�N <br />0 <br />= <br />^L' <br />0) <br />m <br />W <br />\ <br />.� <br />m <br />C.0 <br />� <br />0 <br />cc <br />N <br />�.._ <br />O 0 <br />T <br />T <br />LO <br />T <br />C0 <br />c <br />T <br />(� <br />00 N <br />E <br />m <br />T <br />N <br />o <br />Z <br />Z <br />E <br />H <br />Nc <br />a- <br />U _j <br />Q O <br />JOB <br />NO: <br />20-6222 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.