Laserfiche WebLink
TYP @ 1 <br />CORNERS D2 <br />U.N.O. <br />EXT. WALL <br />TO BE 2x4 #2 <br />SPF STUD @ <br />16" O.0 <br />U.N.O..O. <br />0 <br />16 <br />MIV <br />2x6 BEAM 15 r <br />SLOPED CEILING 14 <br />TO MAINTAIN T-5" <br />HEADER HEIGHT 13 <br />I 12 <br />Z <br />12x8 #2 SYP JOISTS @ LANDING <br />@ 16" O.C. w/ SIMPSON A35 11 <br />CLIP C R LUS26 HANGER TO <br />U <br />LEDGER 10 <br />W <br />I <br />2x12 H R. w/ (3) 2x STUDS AT <br />EA. END FOR BEARING PLYWOOD9 <br />LANDING <br />nv <br />b <br />F- <br />( STANDARD (3) 2X12 <br />0 <br />STRINGERS W/ SIMPSON A35 8 <br />T <br />CLIP TO HDR. <br />00 <br />0 <br />00 <br />1 x TREADS (TYP.) 6 <br />2x8 LEDGER #2 SYP w/ <br />CONT. (3) 16d NAILS TO STUD <br />5 <br />HANDRAIL @ 16" O.C. <br />Me <br />/4 <br />Ln <br />/3 <br />/ <br />J2 <br />THRUST BLOCK SECURED TO <br />SLAB w/ 1/4"X3 1/2" TAPCONS <br />@ 16" O.C. <br />I- qQ'-n" <br />18'4" <br />20'-4" <br />01 <br />1. <br />25 <br />6 <br />SH H1 D6 <br />R&S <br />EGRESS <br />('------ <br />----1 <br />J <br />� <br />S6 <br />` J <br />cco <br />SURROUNB <br />TYP @ 2 STORY <br />W.I.C. <br />B <br />DROOM <br />4 <br />P <br />'8'_0" FLAT CLG.' <br />8'-0" FLAT CLG. <br />BEDROOM <br />3 <br />rni <br />I <br />I U) <br />CARPET <br />j <br />8'-0" FLAT CLG. <br />I <br />�1 <br />I <br />o <br />L <br />N <br />CARPET <br />¢ <br />w <br />- T-1 2' - <br />- <br />ROOF G.T. _ <br />_ <br />- <br />_TIL <br />W <br />13'-0" <br />z <br />1 V-8" <br />iv <br />6 52' <br />2 -4 <br />4 2200 <br />o <br />t <br />~ <br />C7 <br />U- <br />1 <br />TYP @ 2 STORY <br />--�- <br />0 <br />O0 <br />J <br />oo <br />(0 4068 B.F. <br />N <br />1 <br />- <br />T, <br />z 8'-10" <br />I <br />I S6 <br />I <br />N <br />=w w L�: <br />iv <br />4068 B.F. <br />60"X36" <br />�'' <br />cn o z_ m <br />2'-3" > <br />SHOWER <br />------ <br />ITB <br />----- <br />'O_ 00 <br />CO <br />FIBERGLA <br />`I <br />R&S <br />o <br />cy <br />00 <br />is <br />2668 <br />------------- <br />SUR�OUN <br />- `� <br />--- <br />4'-0" <br />5' 10" <br />S <br />00 <br />6'-1 <br />5'-4" <br />2 <br />-4z <br />2668 <br />13'-72' <br />cn <br />-- <br />- <br />- <br />o <br />Q <br />� <br />" <br />M <br />BEDROOM 2 <br />90 <br />N <br />W <br />24 '8 <br />8'-0" FLAT CLG. <br />' 0 <br />r31i �x22 <br />CARPET <br />8' <br />LA <br />:ILE�' <br />CL <br />a <br />10 <br />it <br />ATTIC <br />I'9�=---�I <br />I <br />li <br />oo <br />cbN <br />o <br />- <br />p `q <br /><L <br />m00 <br />i <br />00 LO <br />O <br />m - a <br />I <br />TIE <br />c00o =w ICU <br />I <br />T �Z0 <br />HA SON BOX <br />1 <br />1 <br />" <br />@ 6" A. F. F. <br />2868 <br />2'-4 <br />_10' <br />S'" <br />2' 6" <br />16'-8" in <br />N <br />4.'_o-" 31_721" <br />MASTER <br />/A�AG.SUITE <br />LOFT <br />15 _ -- <br />- <br />i <br />rn <br />8'-0" FLAT CLG. <br />15 <br />I <br />00 <br />W <br />CARPET <br />- -- <br />I <br />8'-0" FLAT CLG. <br />O <br />ROOF G.T. <br />14 <br />-- <br />_ - <br />CARPET <br />- <br />- <br />"' <br />12 <br />z <br />I <br />�?N <br />O <br />LO <br />N <br />11 <br />II r <br />_ <br />10 <br />TYP @ 2 STORY <br />4 1 <br />I <br />5 1 6 1 7 1 8 9= <br />I I I I <br />l 0 ¢ <br />TYP @ 2 STORY <br />S6 <br />7I <br />1 <br />I I I I <br />i fV U- <br />I <br />I I I I <br />I <br />II <br />S6 <br />1 <br />8 <br />38'-0"It <br />39'-0" <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 9/16" <br />10" TREADS w/ 1" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 <br />inch and not more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing <br />projection shall not exceed the smallest nosing projection by more than 3/8 inch between two stories, including <br />the nosing at the level of floors and landings. Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located <br />more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to <br />the edge of the open side. Required guards at open -sided walking surfaces, including stairs, porches, balconies <br />or landings, shall be not less than 36 inches in height as measured vertically above the adjacent walking surface <br />or the line connecting the leading edges of the treads. Required guards shall not have openings from the walking <br />surface to the required guard height that allow passage of a sphere 4 inches in diameter. <br />Under -stair protection: <br />Enclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the <br />enclosed side with 1/2-inch gypsum board. <br />rIN <br />SIN <br />3 <br />D2 CONT. HANDRAIL <br />RETURN TO_ <br />WALL DETAIL <br />DA <br />SCALE: NTS <br />H2 >4 <br />D2 <br />Cn o <br />N Cl) <br />SEE PLAN FOR LANDING DEPTH <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />MIN. (3) 2x STUDS REQ'D GENERAL FLOOR <br />9 @ END OF LANDING BELOW HDR. BEAM. CONSTRUCTION NOTES <br />T = 2x8 #2 SYP JOISTS @ LANDING <br />3SIM. W/ STANDARD (3) 2x12 MP34 OR LUS26 HANGER ONSP <br />D2 EA. SIDE <br />3.5" x 5.25" STRINGERS w/ z <br />PL 1.8E SIMPSON A35/USP o <br />FB - 2900 MP34 CLIP TO g MASONRY OR WOOD WALL, <br />FLOOR SYSTEM OR SEE PLAN <br />6 LANDING FRAMING o 2x8 #2 SYP (P.T. IF MASONRY <br />H1 D2 (2) 2x HDR. a WALL) CONTINUOUS LEDGER <br />REQ'D @END OF w w/ (3) 16d NAILS @ 16" O.C. MAX. <br />LANDING FOR � TO EA. STUD. ((2) 1/4"X3 1/2" <br />STRINGERS TO TITENS @ 16" O.C. MAX. FOR <br />CONNECT TO MASONRY WALL) <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />00 <br />I � <br />I <br />r <br />- � <br />I <br />L <br />I <br />_ J <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />V-0" MAX LANDING LENGTH <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />14()(1 <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />* IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT <br />CORNERS <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT ** <br />SEE C/S6 WALL SCHEDULE <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 4 X 25 4 <br />S.H. <br />13 <br />20 X 38 J <br />18 7' X 371 <br />S. H. <br />14 <br />20X50J <br />184X50 <br />S.H. <br />15 <br />20 X 63 <br />1871 X 62 4 <br />S. H. <br />16 <br />20X72 <br />18JX714 <br />S.H. <br />iH2 <br />271/4X26 <br />26X25� <br />S.H. <br />1 H3 <br />27 1/4 X 38 <br />26 x 371 <br />S.H. <br />1 H4 <br />27 1 X 50 1 <br />26 x 50 <br />S. H. <br />iH5 <br />27JX63 <br />26X621/2 <br />S.H. <br />11-16 <br />27�X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 X 25 1/2 <br />S.H. <br />23 <br />37 1 X 38 J <br />36 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 25 � <br />S.H. <br />33 <br />54X38J <br />524X37i <br />S.H. <br />34 <br />54 X 501 <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 } X 71 } <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel 1 inch minimum rigid nonmetallic class 0 or la 1 <br />g c ss <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />�q <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />�C <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />�E <br />+26.6 / -28.0 <br />0 <br />+26.6 / -32.2 <br />GO <br />SEE SN SHEET H SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />[11111111111111111MASONRY <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />6 <br />AREA TABULATION "B111 <br />H8 DZ <br />FIRST FLOOR LIVING <br />AREA 1093 <br />SECOND FLOOR LIVING 1489 <br />AREA <br />LIVING TOTAL 2582 <br />0 <br />tO <br />GARAGE 427 <br />- <br />FRONT ENTRY 35 <br />TOTAL AREA 3044 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x <br />R-1KRAFT FACED <br />SECOND FLOOR PLAN <br />B 1 <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />(GARAGE / LIVING) <br />R-11/R-13 KRAFT FACED <br />SCALE: %4'=1'-O" <br />,`$®t,stottteilriaFyoa <br />i <br />,3 <br /><: <br />To the best of the Engineer's knowledge, information and belief, <br />plans and specifications contained <br />the structural P <br />P <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0p9E <br />00 <br />"ON3'k <br />} '{ <br />M N C <br />n� <br />4) N J <br />4ko� <br />® <br />N <br />2 M 0) O <br />LL <br />J * W <br />LL d <br />a <br />N <br />mmi� <br />rla� <br />Z <br />> .c <br />� <br />0 = O <br />rarn <br />Mao <br />= m o <br />Wm <br />0 1- <br />onco <br />LLW <br />E (1, <br />o 9 <br />co <br />Z <br />m N OI= <br />N Q M Z <br />o <br />O J <br />Z <br />OU <br />V <br />❑❑❑ <br />W <br />Z N O <br />� ¢N <br />Z O <br />(Z N <br />� o <br />92 <br />X4-d <br />w a <br />a <br />a <br />•ULAW— <br />tN <br />- <br />w <br />E <br />U °°° <br />w m <br />r- T s <br />- o g <br />m i <br />U o <br />c , (D <br />to, <br />14 <br />r_ <br />O <br />c <br />J <br />w <br />coo <br />co� <br />p <br />z <br />� <br />cd E <br />Cz O <br />wo <br />z <br />,� <br />p a <br />U <br />K Ooo <br />U <br />Do <br />CDaz <br />@ <br />¢ <br />az <br />w <br />N <br />a) i <br />oo <br />¢o <br />i <br />m� <br />_ c <br />Y <br />"m <br />Z <br /><W <br />r) <br />M <br />N 3 <br />8l <br />z <br />ao <br />Q 3 <br />Z <br />Nz <br />�z <br />=5 <br />o <br />�o <br />O <br />N <br />a F <br />�U <br />° N <br />= <br />Lo <br />oc <br />L <br />m <br />n' <br />W <br />co <br />.! <br />M <br />W <br />T <br />^ <br />= <br />O <br />0 <br />O <br />/11 m <br />c <br />Ln <br />o <br />di <br />.� <br />J N <br />r <br />LnLO <br />= <br />0 <br />N <br />M <br />� N <br />,-- <br />E <br />(0 <br />c <br />0' C <br />N �- <br />o <br />co <br />Z <br />r <br />E O <br />�; <br />- <br />z <br />a <br />E <br />U � <br />¢ p <br />c <br />JOB <br />NO : <br />20-3567 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.1 <br />