My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3003 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3003 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:53:28 AM
Creation date
2/28/2025 11:03:41 AM
Metadata
Fields
Template:
Building Plans
Street #
3003
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
128
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS COVER SHEET <br />1 FLOOR PLAN <br />2 INTERIOR ELEVATIONS <br />3.1 EXTERIOR ELEVATIONS <br />3.2 EXTERIOR ELEVATIONS <br />F1 FOAM DETAILS <br />4 ELECTRICAL PLAN <br />5 ROOF PLAN <br />6 FOUNDATION PLAN MONO <br />7 ROOF FRAMING PLAN <br />8 LINTEL PLAN AND DETAILS <br />SN STRUCTURAL NOTES <br />ABBREVIATIONS SN1 DETAILS <br />AB or A.B. Anchor Bolt FIX or FXD Fixed PWDR or Pwd. Powder Room S3 DETAILS <br />ABV or Abv. Above FLR or Flr. Floor RA or R/A or R.A. Return Air S4 DETAILS <br />AC or A/C Air -Conditioner FLR SYS or Fir Sys Floor System RAD or Rad. Radius <br />ADJ or ADJ. Adjustable FOM or F.O.M. Face Of Masonry RAG or Rag. Return Air Grill S5 DETAILS <br />AFF or A.F.F. Above Finished Floor FP or F.P. Fireplace REC or Rec. Recessed SS RETROFIT DETAILS <br />AHU or A.H.U. Air Handler Unit FIR DR French Door RECEPT Receptacle _ <br />ALT or ALT. Alternate FRT Front REF or Ref. Refrigerator — D1 SECTIONS & DETAILS <br />BC Base Cabinet FT or Ft. Foot/Feet REINF Reinforcing WP WATERPROOFING DETAILS <br />BF B'Ifold Door FTG or Ftg. Footing REQD or Req'd. Required <br />BK SH or Bk Sh Bookshelf FXD GL Fixed Glass RM or Rm. Room PA1.0 PRODUCT APPROVAL NUMBERS <br />BILK or BILK Block GALVor Galy. Galvanized RIND or Rnd. Round PA1.1 PRODUCT APPROVAL NUMBERS <br />BLW or BLW. Below GC or G.C. General Contractor RO or R.O. Rough Opening — — — — <br />BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter IRS, R/S, R/SH or R&S Rod and Shelf — PA1.2 PRODUCT APPROVAL NUMBERS <br />BOT or Bot. Bottom GT or G.T. Girder Truss SD or SD. Smoke Detector <br />------------- <br />BP or B.P. Bypass (door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door <br />BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves — <br />C Carpet HDR or Hdr. Header SHT Sheet <br />CAB Cabinet HGT or Hgt. Height SHWR or Shwr. Shower <br />CJ r /J Circle HH or H.H. Hand Held (plumbing faucet) SL or Side Lights rLF- 0 FE7: 11 F=7 D <br />CI or Ci Control Joint HH or Horizontal SPECS S.L.L. SPECS. Specifications <br />CLG or Cig. Ceiling HS Hard Surface (flooring) SPF or S.P.F. Spruce Pine Fir <br />CMU Concrete Masonry Unit ILO In Lieu Of SQ SF or S.F. Square Foot (feet) <br />COFF or Coff. Coffered or Tray Ceiling INSUL or Insul. Insulation SQ or or Sqq . Square <br />COL or Col. Column INT or Int. Interior STO Storage D El Fp El 1= <br />COMM or Comm. Community Kor KlWall Knee SW S.W. Shear Wall <br />COMP or Comp. Compressor KSS or or K.S.K.Knee Space SYP or <br />or S.Y.P. Southern Yellow Pine F=7 IEII <br />CONN or CONN. Connection LAUN or Laun. Laundry TB Towel Bar 77777 <br />CONT or Cont. Continuous LAV or Lay. Lavatory TEMP or Temp. Tempered LA❑ p <br />p <br />7=1 <br />p <br />❑ <br />CT or C.T. Ceramic Tile LF or L.F. Linear Ft. THIKN or Thik'n. Thicken <br />El <br />D or D. Dryer ILL Lintel Length TOB or T.O.B. Top of Block <br />DB Door Bell LT Laundry Tub TOM or T.O.M. Top of Masonry <br />DBL or Dbl. Double MAS or Mas. Masonry TOP or T.O.P. Top of Plate <br />DCF Decorative Cementitious Finish MAX or Max Maximum TP Toilet Paper Holder <br />DEC or Dec. Decorative MC Medicine Cabinet TR Towel Ring <br />DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TRANS WDW or Trans. Transom Window <br />DIA or Dia. Diameter MGT Management (room) TYP or Typ. Typical <br />DISP or Disp. Disposal MIN or Min Minimum UC or u.c. Under Counter <br />DIST or Dist. Distance MIR or Mir. Mirror UCL Under Cabinet Lighting <br />DMF Decorative Masonry Finish ML or M.L. Microlam LINO or U.N.O. Unless Noted Otherwise <br />DS or D.S. Drawer Stack MONO or Mono Monolithic V or v. Valve (shower or tub/shower) <br />DTL Detail MIN or MICRO or Micro. Microwave VB Vanity Base <br />DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VERT or Vert. Vertical <br />DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VL or V.L. Versalam ALI WORK SHALL COMPLY WITH PREVAILING <br />DIN or D.W. Dishwasher OPNG or Opn'g. Opening VTR or VTE Vent through Roof / Exterior CO 3ES FL0i7,:0A BUILDING GODE, <br />EA or Ea. Each OPT or Opt. Optional W or w Washer NA ONAL ELECTR!C' CODE, <br />ELEC or Elec. Electrical PC Pull Chain W/ or w/ With AN THE CITY O;y." 44-PHYRH LL <br />ELEV or Elev. Elevation PED or Ped. Pedestal WA or W.A. Wedge Anchor <br />EQ Equal PH Phone WC or W/C or W.C. Water Closet (toilet) <br />EW or E.W. Each Way PKT or Pkt. Pocket (Door) WD or Wd Wood REVIEW �� a <br />EXP or Exp. Expansion PL or P.L.Parallam WDW HDR or WDW. HDR, Window Header <br />EXT or Ext. Exterior PLF Pounds per linear foot WH or W.H. Water Heater CITY OF ZEPHYRH IL <br />FBC Florida Building Code PLNT SHLF or Pit. Sh. Plant Shelf WC or W.I.C. Walk-in Closet PLAN EXA <br />FDN or Fdn. Foundation PLT HT or Pit. Ht Plate Height WM or W.M. Wall Mounted (plumbing future) <br />FG fiberglass (Shower Pan) PSF Pounds. per square foot WP Water Proofing) MEAN ROOF 15 FT. HIGH TYPICAL <br />FIN Finished PT or P.T. Pressure Treated WS Water Softener FOR SINGLE STORY HOMES <br />FIN FLR or FF or Fin. Ar. Finished Floor PW or P.W. Pre -wire VW Welded Wre Fabric (Mesh) <br />PLAN REVISIONS MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />DATE VERSION DESCRIPTION THIS DRAWING AND DESIGN IS VALID <br />08-20-15 1.0 NEW BASE PLAN FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />12-8-15 2.0 ADDED VAULT. CLG . <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />12-28-17 3.0 2017 FBC UPDATES SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />08-2 7-19 4.1 ENG. REVIEW FOR 150—C MPH Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />09-20-19 4.2 ADD 8'-8" ELEV . FOR T R EV E STA the commencement of any work. The Designer/ neare not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Zug Payments will be made in accordance to the terms of the <br />agreement. <br />Control of Construction Site: <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />1 941 vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />S E <br />�:GV <br />V� <br />, <br />4r <br />,'t`�Pa!f f 1►1141614z����°� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing <br />pages bearing <br />Engineer's signature and seal. <br />@i <br />Fp00 <br />Q U N N it <br />p p p p <br />r <br />(M N <br />p J <br />0N0 LL. <br />7-,J <br />uL - a <br />,n CM I <br />Q P <br />Z-0 <br />W <br />t a u, <br />0 zW <br />rn <br />o _ <br />�00 OMO <br />W2 <br />A.o o c° <br />m <br />N Q M ZZIL <br />U <br />0 <br />Z V ❑❑❑ <br />W <br />N <br />Q <br />co <br />o <br />vz <br />� N <br />t/1 o <br />CZ <br />V) 0 <br />W fl' <br />� n <br />U <br />-LL1 <br />U <br />W <br />= <br />r— e <br />o <br />I <br />I, <br />= d <br />U ) m <br />c `� ID <br />¢ o <br />° <br />— 0 <br />o <br />W <br />MNa <br />M <br />o <br />Z <br />Z <br />c6E <br />Ow? <br />z <br />o0 <br />?o <br />z® <br />oa <br />S <br />XU <br />00 <br />O E <br />N r0 <br />O <br />�¢o <br />ww <br />L <br />¢ <br />ttw <br />m 0 <br />=3 _ <br />ME <br />U <br />N <br />o, <br />Z <br />_I <br />m <br />a <br />Q W <br />Z <br />to <br />C1. <br />02 <br />� <br />o <br />z <br />�w <br />U <br />its <br />`_& <br />o <br />d= <br />�� <br />' H <br />�o <br />lllllllllll� <br />O <br />zla <br />a� <br />3 <br />�N'. <br />J <br />L <br />� <br />m <br />m <br />^' <br />W <br />m <br />0 <br />. — <br />T- <br />L.L <br />Q'- <br />C <br />O <br />... <br />c <br />d. <br />r <br />d' <br />>' N <br />J <br />r <br />CD 0 <br />0 <br />ai <br />m <br />M r <br />r iii M <br />o <br />Z <br />Z <br />E 0 <br />E ai <br />f° <br />ac0 <br />¢ cc <br />JOB <br />NO: 20-2742 <br />SCALE : AS NOTED <br />SHEET NO. <br />C S <br />c <br />
The URL can be used to link to this page
Your browser does not support the video tag.