Laserfiche WebLink
CORNER OF <br />HOME <br />GARAGE SIDE <br />J <br />c7 <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />PInr.F I INF <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + o <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ + <br />+ <br />+ <br />'-0" (TYP.) <br />6'-0" <br />+ <br />+ + <br />6'-0" <br />+ + <br />+ <br />+ <br />+++ <br />+++ <br />+ <br />+ <br />+++ <br />+ + <br />+ + <br />++ <br />+ <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + o <br />+ + <br />+ + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + + <br />+ + <br />++ <br />+++ <br />++++++++ <br />+ <br />0i <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />\—RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ V O.C. EDGES & <br />+ + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0,012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />P — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.811.7 <br />Wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/$" or two 1/2" <br />60 2.0 <br />wood panels <br />2x + 5/8" or 3/4" wood panel <br />90 Z.0 <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />k <br />k / � 1'i <br />I/ <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />FILL CELL <br />w <br />CONT. #5 > STD. 90° <br />BAR HOOK <br />STD. 900 HOOK BOND BEAM <br />• <br />SIMPSC <br />w/ (22) . <br />NAILS 1 <br />CONT. #5 <br />OOC BAR <br />0 #5 CONT. <br />FROM <br />FOUNDATION <br />I <br />5/8"0 <br />THRU <br />BOLT <br />ri <br />TO HIGHEST <br />BOND BEAM <br />BEAM STEP <br />BOND <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" ax <br />m V 4 max. <br />-7 Clinch nails <br />when <br />possible <br />2) <br />Block solid between joists for full length of span. <br />Tight fit U (� <br />2 x _lumber Double 2 x _lumber <br />3) <br />Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/QSB web stiffener 2" min. <br />4) <br />Place joists together and nail from each side with 2 rows of 10d nails <br />required when indicated or 4" max. <br />2x CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT <br />at 12" o c clinched when possible Stagger rows from opposite <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series I Depth I End intermediate <br />® <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6.8d <br />BCI60sP <br />11-7/8" <br />2-8d <br />3-8d <br />14- <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />OF THE JOIST ASA REQUIRED LEAVING �" GAP @ TOP sides by 6". -Hangers with side nailing. <br />Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* over squash=20 blocks and <br />Non stacking walls wall or beam below.* <br />require additional <br />consideration. Check <br />local building <br />code for appropriate 1/16 <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />lateral load. nail each side <br />10'-0" at bearing. <br />TANK -LESS W/H /l <br />H C G <br />O O O <br />5'-011 ¢ - <br />�- <br />STUB-OUT FOR 1 "_Or1 0 0 <br />LO <br />GAS METER O o <br />� U <br />0 <br />N _ <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5"" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-l" <br />(2)16d TOENAILS <br />2" X 6" @ 24"' O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-01, <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-41" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING , <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />9 <br />BLOCKING PANEL, INTERIOR <br />Boise Joist Blocking Vertical load transfer =1900 plf max. along bearing wall <br />Use 3" (10d) nails at 6" o.c. Required on interior walls: - for vertical load transfer <br />Load bearing walls when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below. <br />CY/ Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />lodhails SECTION @ INT. BRG. WALL require additional consideration.— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />• <br />6A 1," ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yi' <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />8 <br />V-0"` <br />1'-1' <br />1"-2" <br />1'-2", <br />1"-3" <br />4,-3"' <br />1'-7" <br />1"-11" 2'-4" <br />2�9" <br />3'-2" <br />3-7" <br />Any 16" joist <br />12 <br />V-0" <br />V-1" <br />1'-2" <br />1"-2" <br />1'-3" <br />1'-9" <br />2,-4" <br />2'-11;" <br />3'-7" <br />4'-2" <br />4'-9" <br />5" 4" <br />Span (ft) <br />16 <br />V-0" <br />I'4' <br />1+-2" <br />V-2" <br />V-7" <br />2"-0" <br />3'-2" <br />3"-10" <br />4,-9" <br />5,-7'" <br />6,-4" <br />7°-2'" <br />- <br />20 <br />1'-0" <br />14 <br />V-2" <br />V-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />6"-11'" <br />7'-11" <br />8'-11" <br />24 <br />V-0" <br />1'-1" <br />1'-2" <br />V-1 <br />2,-5 <br />3'-7" <br />4'-9"' <br />5'-10" <br />7'-2" <br />8"-4" <br />9'-6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS, <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />SIMPSC <br />w/ (22) <br />NAILS T <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Joist hanger <br />A/C CHASE 4" PVC. <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) -�-1�-11 <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM a ' ' <br />° . : •d.. <br />' a , <br />SEE PLAN FOR °• a . • a . •. <br />FOUNDATION INFO a' <br />STEM FOUNDATION <br />GRADE <br />Filler block. REINF. SEE PLAN <br />\ Nail with <br />10-10d nails. <br />Backer block required where top d n <br />mount hanger load exceeds 250 lbs. 4 I I II I Install tight tight to top flange. , ,,,_„—,_;� <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />- Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4 PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />i HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />/I—P1T10% A 1 TI 1 M 1 1 1—\ 111 <br />TOP (2) #5's x 4' 0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />/ r PLUMBING LINE <br />d L <br />d <br />ifl • -1.. 0 <br />a <br />-/ <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATIONF/r— <br />dPLUMBING LINE <br />a' A n <br />C. A dC <br />d <br />-Tj�— a _III11T�11� <br />o a o a Ir <br />.o <br />SEE FND, PLN. <br />SIZE & REINF. <br />4; <br />l <br />i <br />t <br />i` <br />`' ��'t11R49t0�� Efi� <br />IV <br />�,. <br />•°•, E U O <br />.9 <br />rs�zzf/,f <br />0!l�to <br />Jr ai Jp©� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0) <br />W <br />Q <br />V <br />co <br />v <br />o;p <br />O N R it <br />0? <br />ci <br />009 W J <br />MNn <br />y <br />M N W <br />9 FL LL a <br />4 <br />a <br />Z-0U)m <br />U.�NmIW� <br />ai rn u_ ° a <br />0 W o <br />W <br />@ 29 �0 <br />m onr° m m <br />W <br />7" <br />2 ETrn o <br />0) _0 <br />0 0 <br />z <br />N <br />NQcoz V J <br />❑❑❑ <br />W <br />7 <br />M C) <br />Z N <br />�co <br />�co <br />z <br />v <br />J M <br />� N <br />E3 <br />QX <br />_ <br />•J <br />� Y o <br />0 <br />_ <br />O <br />Ln <br />�N <br />w 1 <br />c o <br />N <br />all <br />W_ <br />U o <br />c C <br />'`_ 8, <br />®® <br />m <br />�W <br />M <br />o <br />Z <br />LL <br />E <br />o <br />00 <br />g <br />>N <br />QN <br />fl_ <br />O <br />�= <br />Q <br />Z® <br />° <br />0co r <br />�< <br />U <br />0, <br />o <br />N <br />L <br />¢z <br />W0 <br />Q <br />�z <br />J <br />Wm <br />ro <br />v <br />'m <br />o <br />"J <br />a <br />aw <br />g z <br />U) <br />02 <br />�o <br />U <br />a <br />U <br />ire <br /><o <br />oLL <br />=k <br />r3 <br />o <br />UJ <br />> ° <br />mi <br />to <br />OR <br />0dL <br />J <br />�(y) <br />>M <br />L <br />I, <br />nW1 <br />C <br />T <br />\ <br />�a <br />O <br />co <br />< <br />si <br />O <br />�+ m <br />o <br />h <br />N <br />T <br />O <br />� <br />LO <br />L0 <br />T <br />J N <br />00 <br />Lt7 <br />r <br />..L r <br />N N <br />r <br />.c C)M <br />M <br />O +-- <br />6 <br />z <br />z <br />� <br />C)co <br />- <br />c <br />i <br />U <br />Q Q <br />JOB <br />NO ; <br />20-2750 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />