Laserfiche WebLink
1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />UNACCEPTABLE INSTALLTION <br />DOOR JAMB (REFER _ TO PRODUCT <br />P.T. TO PRODUCT <br />TO PRODUCT APPROVAL FOR CONN. <br />MAX 8„ <br />PROPER INSTALLATION DO NOT DO THIS <br />2"x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN.M1x4 1 X 4 <br />#5 REBARATTACHED <br />(TYP,) <br />3/4' PLYWOOD DECKING GLUED <br />WALL SHEATHING TO <br />3-1/4 LONG X 3/16 � FURRING 3/16"0 X 3" LONG FURRING (2) ROWS 3/16" x 3-1/2" FURRING <br />+� �� TAPCONS <br />#5 REBAR ` ' <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />TAPCON. INTO TAPCON @ 16" O.C. & 4"LL,2X8 <br />STAGGERED @ 16" <br />(TYp,) <br />` <br />1x8 P.T. FROM EACH END w/ MIN. iX8 <br />BLOCK@ SPACING „ O.C. 2-ROWS INTO <br />1 DETAIL L 2 EDGE DIST. ATTACH <br />PER MANUFACTURE MASONRY THROUGH 1-1 /211 DETAIL 1A w/ (2) ROWS 8d NALS �� <br />3 DETAI L <br />d <br />STD. 90" ` TD. 90 HOOK (TYP.) <br />2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />1x4 P.T. & 1x8 P.T. STAGGERED @ 12" O.G. <br />FILL SOLID HOOK (TYP.) <br />BOTH CELLS <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />x 3 -1/2° TAP DOOR JAMB (REFER <br />TAPCON @ 16" 1x4 P.T. <br />TO PRODUCT <br />El E; <br />METAL SEAT PLATE <br />O.C. & 4" FROM DOOR JAMB (REFER 1/2" DRYWALLJIL <br />NOTE: <br />EACH END W/MIN TO PRODUCT APPROVAL FOR CONN. 1x4 <br />VE71a P/ <br />LAP SHEATHING TO <br />DOOR JAMB (REFER*Z,'EDGE <br />TO PRODUCT DIST. APPROVAL FOR CONN. 2x8 P.T. w/ (2) ROWS 3/16" <br />' ` <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />APPROVAL FOR CO - x 3-1/2" TAPCON @ 16" 1x4 <br />(2) ROWS 3/16 x 3 1 /2 O.C. & 4 FROM EACH <br />FURRINGSIMPSON <br />— TAPCON @ 16" O.C. & END w/ MIN. 2" EDGE DIST. <br />M 4" FROM EACH END w/ 2x8 P.T. ATTACH SECOND PLY w/ <br />' +2„ NOTC F @FIRST COURSE <br />HGAMIOKTA @ 12" O.C. <br />w/ x1 1/2" SDS SCREWS <br />.T. AS REQ'D MIN. 2" EDGE DIST. (2) ROWS 10dx3" 2x8 <br />` <br />I � <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />2x DETAIL 21 /4" DETAIL STAGGERED @ 12" 0' 3-1/4" DETAIL <br />� FA FIRS 2 COURSESTE ' <br />` <br />TITEN INTO K.O. BLOCK <br />BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />LED CELL PER <br />FOUNDATION <br />PLAN <br />FILLED CELL INSTALLATION H <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. SS <br />SEE TYP, 2-STORY WALL SECTION FOR ADDL. <br />INFO SCALE: N.T.S. <br />SCALE: N.T.S. <br />SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK SECTION <br />UPLIFT CAPACITY = 805 # FOR 1 STRAP <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. A -A <br />=1610 #FOR 2 STRAPS <br />' < FILL 1st4000RSES <br />EMBEDMENT INTO BILK.) 1/4" MAX <br />SOLID WIGROUT <br />Ir 2'-0" 8" <br />1 PLY PRE-ENGINEERED TRUSS <br />1 X 4 FURRING SOLID BLKG. AT TOP BTWN. 1/4" x 31/4" TAPCONS <br />BLOCK HEADER ARCH BLKG. &BUCK <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />° <br />1/2" DRYWALL * <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />8d NAILS AT 8" O.C. AT BUCK <br />SINKERS AND (7)1/4"x2 1/4" TITEN = 2150 #) <br />2 x 8 45' DIAGONAL (4)10d NAILS INTO LEAVE A CUTOUT IN O.S.B. ON THE <br />BRACE(S) 2 x 8 BRACE/ BLKG. INSIDE TO ALLOW FOR INSULATION <br />° <br />7/16++ OSB TO BE INSTALLED <br />BOND BEAM OR CAST IN PLACE BEAM <br />FOR OVERHANGS BETWEEN OVER 1112 <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />POLY -CELL IN THIS AREA 2 x 8 45 DIAGONAL BRACE AT EA. <br />CONTACT ENGINEER of RECORD FOR <br />FURTHER INSTRUCTIONS. <br />. <br />SCRIBE NOTCH <br />(NOTCH) FACE OF ARCH W/ (3)10d NAILS <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 AT EA. END <br />RETROFIT TRUSS DETAIL <br />• :4' ...• <br />OVERRAN ° <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />N.T.S. <br />a• • <br />INSTALL WDW. SCREW ANCHOR 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB PROVIDE TAPCON WITHIN <br />ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />° <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />INTO ARCH BLKG. PER 4" MIN. OF BRACE <br />INSTALLATION DETAILS A <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />BETWEEN 3/4" <br />-A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />FOR OVERHANGS TO 1 1/2" <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />IF TRUSSES USED W/ 3 #6 X 4Y," WOOD <br />) O <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REO'D. <br />START OF ARC <br />SCREWS @ 16" O,C. MAX. OR IF MASONRY WALL <br />NAILS <br />4' MAX. RAD. <br />ARCH DETAIL i <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />kO(FR TO TRUSS OP CHOD <br />, NqN <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />+ ` FNGr <br />rrr <br />1r- 0" 5- 0 <br />SCALE: N.T.S. SS <br />12 <br />+ h PLYWOOD SHEATHING <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24 O.C. <br />+ + <br />OLf INISH FLO qR <br />2 <br />x 8 BUCK - CONNECT TO BLOCK SECTION <br />+ + BLOCKING AS <br />° <br />WITH <br />1/4" x 31/4" TAPCON (1 1/4" MIN. B-B <br />ROOF SHEATHING ATTACHED <br />+ REQUIRED <br />/4" MAX EMBEDMENT INTO K.) <br />PER NAILING SCHEDULE ALL <br />TO SUPPORT <br />TRUSS + <br />°.. ° _ >: #5 BAR <br />BLOCK HEADER <br />41 T-01+ 8+, <br />* <br />SOLID BLKG. AT TOP BTWN. ARCH <br />5 12d NAILS SIMPSON <br />(} <br />SOFFIT <br />+ + <br />, > <br />D• 10" e P d ° ° 2 <br />CENTERED W/ <br />1 X 4 FURRING <br />BLKG. & BUCK <br />2X6 TO 2X4 H2.5A wl (10) <br />8d NAILS <br />2X4 SYP . ®s <br />EACH TRUSS <br />o • . ° 'P s H IN TOP 4 <br />o a KNOCKOUT/ N <br />,'' <br />; ° CHAIR BLOCK*4% <br />8d NAILS @ 8" Q.C. AT BUCK <br />PROVIDE 2 8 DIAG. BRACE BTWN., <br />2 x 8 VERT. W/ (2) 10d <br />NAILS AT EA. END <br />PROVIDE (2) MIN. <br />PROVIDE 2x • <br />CONT, W/ <br />CONNECTOR si <br />= d <br />MONO FOOTING _ _ .A .p.. . , ° <br />x <br />(3) <br />SIZE AND REINF. PER PLAN <br />VERT. BRACES WHEN HGT. OF N, <br />TAPCON AT EA. SIDE <br />12d NAILS <br />SEE LINTEL <br />AND SECTION DETAILS -I <br />BRACE EXCEEDS 24" <br />BUCK - (1) WITHIN 4" <br />JACK TRUSS PROVIDED BY <br />SCHED• <br />-I <br />LEAVE A CUT OUT IN O.S.B. ON T <br />MIN. OF START OF <br />TRUSS COMPANY OR 2x4 <br />e <br />CLEAN FILL °• <br />2 x 8 VERT. BRACE(S) <br />INSIDE TO ALLOW FOR INSULATION <br />ARCH <br />#2 SYP @ 24" O.C. <br />ENTER SO IT <br />.> <br />DIRT Z <br />TO BE INSTALLED <br />000, <br />BUILT UP PLWD. BUCK - <br />4'-0" MAX SEE PLAN <br />PRECAST LINTEL <br />° STANDARD <br />°'. �? <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH <br />SEE ELEVATION <br />n 90 HOOK N <br />#5 BAR IN • <br />TO FIT ARCH CONNECT W/ <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />FOR OVER HANG <br />FILLED CELL, -. - • <br />8d NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />START OF ARC <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />(MAX. 4'-0") <br />• • <br />, • , . . ', . '1 v _ . , <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL EQUAL <br />4' MAX. RAD. <br />WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />_, <br />�' •�'�'• <br />INSTALL WDW, SCREW <br />THRU OSB INTO 2x8 <br />O.C. <br />`�'• � o'''• � � �`� ° � �`�'• <br />Sk <br />ANCHOR INTO ARCH BLKG.STEMWALL <br />FOOTING SIZE AND <br />PER INSTALLATION DETAILS <br />e-gMONO <br />ARCH DETAIL K <br />SECTION @ENTRY Kl� <br />SECTION Ca@ ROOF EXTENSIONrm­�� <br />REINF. PERLAN AND STEMWALL <br />TO STEMWALL FOOTING <br />SCALE: N.T.S. 111, <br />SS <br />1' SCALE: 3/4" = -0" SS <br />1' SCALE: 3/4" =-0" SS <br />SECTION DETAILS <br />SCALE: 3/4" =1'-0" <br />GLASS BLOCK INSTALLATION NOTES <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT, <br />A) COVER .SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION, ALLOW EMULSION TO DRY <br />CONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />EXISTING BOND BEAM. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />MASONRY WALL. SEE PLAN FOR <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED, ALL MORTAR SHALL BE <br />SEE SHEET D2 AND <br />EPDXY CAP TO PREVENT LEAKAGE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP <br />FLOOR PLAN FOR <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL <br />MORE INFO <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />SIMPSON HTT4 w/ (18)10d x 1 <br />" MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2 ) <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />W.W.M. AT PERIMETER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 <br />WHERE THIS CONDITION <br />1/2" NAILS TO STUDS & (1) - <br />PER ANCHOR <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL ) <br />(1) #5 BARS CONT. OCCURS <br />5/$" DIA. ALL THREAD ROD <br />"SET" <br />z <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. THE SAME SPACING <br />( REINFORCING <br />TOP WITH MIN. 3" <br />EPDXIED w/ SIMPSON > <br />O <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER <br />COVER 6'-0" F.F <br />EPDXY MIN. 6" EMBEDMENT & <br />FILL CELL FULL HEIGHT W/ <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP <br />3" MIN. EDGE DISTANCE <br />�- I'' <br />NON SHRINK GROUT. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />° <br />O U <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />o ;' u <br />v a <br />A <br />REINFORCING AS FOLLOWS: <br />SEALANT <br />— j <br />t¢ a <br />PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />—— — — - <br />-1�1 <br />#5x6 EMBEDDED INTO <br />PRESS PANEL REINFORCING INTO PLACE. <br />6 MIN. LAP SPLICE W/�� <br />- S <br />, _ <br />— <br />U z <br />� � <br />EXISTING FOOTING (2) #5x6 IN CONC. <br />_ <br />COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL <br />— —I I i= <br />rLO <br />SMOOTH. DO NO FURROW, <br />°. <br />to <br />FED IL L CELL <br />a — <br />DRILL 3/4"x5" MIN. HOLE <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />GRADE o �1= j I- <br />SET BAR IN EPDXY <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6" MIN. LAP <br />EJ <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE <br />(V ° ' �p <br />\ � <br />REMAIN FREE OF MORTAR. NOTE: <br />"' z \ <br />� <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION NOTES. <br />r P <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT <br />, ° <br />4" SAW CUT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL <br />\ ° (2) #5 REBAR. MIN. 3" <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />" COVER EA. WAY <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />16 MIN, <br />A SECTION <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />EXISTING FOOTING <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />j SCALE: N.T.S. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />SECTION AT DEEP MONO FOUNDATION <br />RETROFIT FOR MISSING MSTAM STRAP <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />RETROFIT <br />FILLED CELL DETAIL <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />= <br />SCALE: 3/4 1=0 <br />SCALE: 3/4„= -1-0 „ <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />SCALE: N.T.S. <br />INSTALLATION OF GLASS BLOCK. <br />� yt <br />r <br />j <br />'16 <br />0 <br />Ua <br />//llllliil' <br />�, <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />a8 <br />I <br />cecpp <br />O V N 4k <br />0 <br />s N N LL <br />��m N <br />ei <br />LL <br />7 LL �2 L <br />a <br />S W + ui <br />,6"' <br />CD LL ZS 1 a <br />Z <br />a�a°' �0 <br />a � m o <br />W <br />W <br />M 0 1 � m� <br />MY E� J o a <br />Z <br />IL <br />i <br />N Q M z U <br />z <br />J <br />°d ❑❑❑ <br />W <br />_ M ' <br />Z N O <br />z <br />o <br />z <br />J M <br />CZ N <br />N <br />_ M <br />M <br />0 <br />4--J <br />� <br />.0 <br />V> Y <br />w o <br />a Q <br />� <br />w <br />� o <br />® <br />'- <br />U 0° <br />w rn <br />o s <br />3 <br />=I� <br />= <br />U ) N <br />W <br />¢ 0 <br />m <br />° <br />®® <br />4 <br />00 <br />o <br />W <br />M <br />z2 <br />o <br />Z <br />LL_ <br />o <br />>o <br />?® <br />E v <br />wI <br />� <br />C, <br />wa <br />05 <br />oa <br />00 <br />°z <br />Z <br />N <br />i <br />¢o <br />wZ <br />Wo <br />m <br />�� <br />a <br />a <br />o <br />�m <br />mg <br />o <br />Z, <br />aW <br />z <br />J <br />�z <br />u <br />aw <br />Q <br />w ¢ <br />a <br />N W <br />C3 <br />w� <br />1~ <br />>° <br />o <br />Z ¢ <br />I <br />61 <br />2M <br />= <br />>M <br />W <br />' <br />M <br />ns <br />'= <br />;— <br />O <br />0 <br />CD <br />W m <br />00 <br />= <br />c o <br />O N <br />0) <br />LO <br />L0 <br />N <br />00 <br />r <br />L0 <br />r <br />I r <br />N N <br />r <br />c O <br />o .— <br />M <br />O <br />E <br />MM <br />z <br />E O <br />y <br />z <br />m <br />C <br />a <br />E <br />U J <br />w <br />Q L] <br />C <br />J <br />JOB <br />NO: <br />20-2750 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />