Laserfiche WebLink
t 1 I!.L---LL— , , -- — - ' <br />8"x8" SMOOTH <br />TEXTURES CORBELS <br />1" x 9" SMOOTH <br />TEXTURED 12 <br />FREEZE BAND <br />5 <br />HEEL <br />� F30 <br />io <br />T.O.M. — — <br />HDR HGT. — — <br />TEXTURED <br />p CEMENTICIOUS <br />FINISH ON C.M.U: <br />-D (TYP.) <br />12 <br />A <br />12 <br />5 <br />—']L------ <br />00 <br />cD <br />I <br />F.FL. <br />+3" SMOOTH <br />1 TEXTURED BAND—/ <br />14'-0" RIDGE VENT <br />12 <br />�5 <br />3 TAB SHINGLES. ..• <br />INSTALLED AS PER MANUF; <br />SPECIFICATIONS <br />MINININKI <br />oa000000 <br />oaa00000 <br />FRONT ELEVATION - 61 <br />T-0" RIDGE VENT <br />SCALE: 1 /4rr=1 r-0rr <br />12 <br />5� <br />12 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />--------- T.O.M. <br />---------------------------------------------------------------- HDR HGT. <br />1-0---------------------------------------------------------------_(Y-- <br />2'-0" <br />TEXTURED o <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />— — — F.FL. <br />LEFT ELEVATION — B1 <br />SCALE: „a.-,..o. <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />L <br />0 <br />O <br />0 <br />CO <br />i H t tJ111111��'i <br />\,`1``,l\ll <br />.......... <br />C•• •�� CV <br />.�• (�, % o <br />✓r : � <br />Gj O� � <br />i�0 <br />o <br />P U <br />� �•( �Q <br />OFESSRO ;! �§ <br />< <br />�l�llltflIk%Ik'`�A <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential Bth Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />F <br />Q <br />�80 ej pp <br />N a! <br />0 <br />Lo <br />S O O 9 ap <br />C N LL <br />(D M <br />0)(0u6 <br />7LL�� u--a <br />a <br />cm W . rn <br />ai PLL 0 a a <br />0 <br />11 <br />0 o <br />Z <br />-0 to rn I <br />.24 X$o <br />Co <br />W <br />Z <br />L <br />mo�rO <br />C"z <br />Vz <br />N �Q C"ZQ U J <br />° <br />❑00 <br />W <br />Z N f0 <br />Z <br />My <br />PI <br />v ' <br />fy <br />• <br />Z O <br />0 rz <br />.0 <br />Q <br />1 <br />Q <br />O <br />W F <br />N <br />c <br />(� <br />r— o <br />2 <br />U °D <br />LLJ <br />125 <br />5 <br />Q <br />�Q <br />sr <br />Mco <br />W <br />_J <br />0 <br />�o <br />Q <br />co E <br />o <br />wLL <br />=_o <br />E <br />E V <br />~ <br />_ <br />52 <br />of <br />o <br />O E <br />N <br />L <br />i p <br />p <br />K =Z <br />w <br />tt� <br />w <br />ro <br />< O <br />m 0 <br />0 <br />z�_ <br />co <br />.8zz <br />b <br />zz <br />0� w <br />W <br />i 3 <br />�o <br />k <br />w� <br />% <br />z1w <br />3 <br />0 <br />�M <br />= <br />aBi <br />> d' <br />T <br />^' <br />W <br />M <br />C9 <br />' <br />■= <br />00 <br />LO <br />X <br />> <br />1"' <br />m <br />� <br />C <br />o <br />ai <br />Oi <br />.� <br />NO <br />r <br />00 <br />O^ <br />r <br />0M <br />m <br />E T <br />\ <br />iri CV)Z <br />c <br />Z <br />c <br />E 0 <br />4 <br />w <br />m <br />c <br />a <br />c <br />U � <br />a p <br />� <br />JOB <br />NO: <br />20-1786 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />