My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3027 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3027 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 12:14:05 PM
Creation date
2/28/2025 11:03:59 AM
Metadata
Fields
Template:
Building Plans
Street #
3027
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
127
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 IL1151 I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />00 AMP 1 <br />2W A#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10.3 copper to Dryer <br />n2/0 or4/0 SER Alu <br />200 amp <br />IDIscon <br />150 amp <br />nett <br />POWER CO. FEED <br />INTERSYSTEM L#4GROUNDING <br />Bare Cu Ground <br />BONDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and Windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />06 <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />LIrIlh <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FANLIGHT COMBINATION 3 GI <br />Q, <br />ELECTRIC DOOR OPERATOR (OPTIONAL) A I III I I r I I I I [ I I I I <br />Cqp <br />I� DEDICATED RECEPTACLE <br />H CHIMES (OPTIONAL) <br />H B FOR MICROWAVE RANGE <br />49 PUSH BUTTON SWITCH (OPTIONAL) GFI DISC. HOOD PER SPECS <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />@ CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />Owl ELECTRIC PANEL <br />i <br />DISCONNECT SWITCH <br />��� <br />ROUGH -IN FOR OPT. CEILING FAN <br />C� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />QI 111 nao <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: Y4'=1'-0" <br />G� <br />O <br />0 <br />0 <br />CV <br />0 <br />CV <br />00 <br />M <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residentsl 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />WE <br />Q <br />totD �p <br />O 8 r. N <br />O N iR <br />�j n X C.9 N LL <br />M N # m <br />0LQ.N-. <br />f/1 W <br />G- a <br />Z <br />air-u; aa� <br />-0(0a, 00o <br />r0CS Xmo <br />19 <br />W <br />m C N t0 m <br />morn <br />2 Earn Q pp a <br />UM <br />ILW <br />(s�Q O y <br />M <br />N 4 <br />Q U� J <br />W <br />v N <br />z <br />z g <br />� lV <br />N <br />z <br />0 <br />ty <br />�+-j <br />f6 <br />U <br />0 <br />�O <br />W <br />�N <br />c <br />� <br />� <br />' ® <br />� o <br />U 0° <br />m <br />Uj <br />�E g <br />=—: <br />U I <br />c N 8 <br />• <br />Q � o <br />S <br />o <br />chi <br />M <br />ZZ <br />o <br />oo <br />Q <br />g <br />z® <br />E O <br />E 0 <br />H r17 <br />x� <br />o0 <br />"' o <br />o¢U¢ <br />U4 <br />Z <br />O <br />C14 <br />ip <br />�r <br />ag <br />Wz <br />re <br />d <br />ro <br />(� <br />z <br />ya <br />m2 <br />O <br />ZU <br />Z <br />(/i Q) <br />J <br />m <br />15) <br />a Z <br />NW <br />W <br />� 3 <br />y�LL <br />�i <br />�; <br />�LL <br />�k <br />o <br />CID <br />z <br />L� <br />�M <br />> d" <br />� <br />D <br />,1 <br />00 <br />LO <br />> <br />T <br />0 <br />Q <br />o <br />0 <br />m <br />= <br />r <br />O <br />0 <br />0 <br />,— <br />00 1 <br />LO <br />N N <br />O 00 <br />T <br />M <br />' T <br />cM ` <br />`� CIO <br />o <br />Z <br />0 <br />E <br />m <br />C <br />a <br />0 � <br />Q p <br />JOB <br />NO: <br />20-1786 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.