My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3039 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3039 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 12:19:34 PM
Creation date
2/28/2025 11:04:03 AM
Metadata
Fields
Template:
Building Plans
Street #
3039
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
132
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12 <br />5� <br />T.O.M. T — <br />11-01, <br />DR HGT. <br />F. FL. I <br />18' RIDGE VENT <br />FRIDGE VENT -4' OFFRI <br />12 <br />�5 <br />®� 3 TAB SHINGLES. ROOF <br />- 16'-7" INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />EXTENDED <br />OVERHANG TO BE <br />CENTERED ON DOOR <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />-------------------------------------------- <br />REAR ELEVATION - B1 <br />4' RIDGE VENT <br />SCALE: 1/4"=1'-0" <br />12 <br />�5 <br />RIGHT ELEVATION - B1 <br />E: 1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN* <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA/ LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />I con) <br />0 <br />C <br />n <br />F� <br />r <br />i <br />\ilill!l11t <br />'�\\0\, �O W N <br />r <br />JV <br />T <br />h <br />Ito <br />O F E <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />MIM M <br />/iW- <br />Cho 00 <br />o pp <br />O U N N # <br />Opp a W <br />ep/�t• <br />C') N N C <br />C" !001FA <br />J <br />N u_ <br />J 7t W <br />ai <br />+�. <br />a <br />13-'6 <br />z <br />11 <br />C) 5 <br />> , U_ <br />-0U)m <br />W O <br />n a it <br />0 o <br />W <br />�rllo_ <br />rem0 <br />m <br />W <br />m o�CO <br />2 EcP rn <br />�� <br />J 0 °- <br />ti <br />Z <br />LLW <br />rnN<'0Z <br />o o <br />U 0O J <br />co <br />N O <br />Z <br />W o <br />2 N <br />z o � <br />Cl N <br />o <br />^U1 <br />W <br />(10 <br />.0 <br />_ <br />C%? Y <br />w o. <br />o <br />n <br />}� <br />',fit`+• <br />� <br />� E <br />w�a <br />r o <br />U m <br />w <br />2 E <br />o 8 <br />I <br />zip. <br />= <br />U o H <br />c rn <br />C <br />CD <br />w <br />cop <br />z <br />z <br />< <br />n. E <br />E 0 <br />Z O <br />o� <br />wz' <br />} <br />¢� <br />Ze <br />ICa� <br />— E <br />XO <br />100 <br />0O0 <br />N <br />L <br />�o <br />¢ <br />a <br />rw <br />2 <br />(d <br />- <br />Y <br />"m <br />m 0 <br />O <br />0, <br />}aW <br />N <br />3 <br />0 <br />5z0 <br />U <br />¢ <br />dz <br />N <br />� <br />O <br />¢ <br />u Y <br />z� <br />0 <br />a0 <br />za <br />�3 <br />�M <br />0 <br />= <br />N <br />M <br />L <br />N <br />(7 <br />u , <br />//'� <br />N <br />T <br />CL <br />_O <br />- <br />0 <br />/� <br />t1/ <br />L <br />1 <br />m <br />2 <br />� <br />Ln <br />. _ <br />J o <br />l.n <br />T <br />1 � <br />O h <br />r <br />ci <br />E: <br />w <br />c T <br />Ch r <br />.. <br />Z <br />cc <br />Z <br />E O <br />N <br />m <br />m <br />IL <br />E <br />U <br />Q p <br />c <br />-1 <br />JOB <br />NO: <br />20-1785 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.