My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3039 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3039 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 12:19:34 PM
Creation date
2/28/2025 11:04:03 AM
Metadata
Fields
Template:
Building Plans
Street #
3039
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
132
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSYI <br />BON <br />TERMINATION <br />NEC 14, 250.94 -/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opper to lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />2 Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF VERIFY METER <br />range 2" AFF <br />LOCATION WITH <br />2. All trim plates & devices to be ganged, where possible. <br />BUILDER H.B. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. \� VERIFY LOCATION _____ _ IRRIGATION <br />6, Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the �� ELECTRICAL PANEL F @ 44 A.F.F. — _ <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. I I I <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and OPT. <br />vapor detector sensor, according to the installation. \�� FAMILY ��4 GF — D. <br />9. R3155.y.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and \ 12 <br />2 CAR GARAGE I I <br />labeled b a National) Recognized Testing Laboratory. <br />�� \ <br />10. Kee all smoke detectors minimum of 36" from bathroom doorsROUGH IN FOR <br />- <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and �\k OPT. CLG. FAN/ _FI' \ I I I <br />shall be equipped with a monitored battery backup. _ _ _ _ I I I <br />LIGHT PRE -WIRE Q <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits G �� �\ L OPT. J \ I I <br />is not acceptable. _ . _ _ _ _ _ — \ I GARAGE I <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an "� J U I DOOR I <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and 1 ` 3' 4 " GFI @ \ w Lu I I <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning I 44" Q 0 I GFI I I <br />when the door or window are opened.. I A.F.F. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing I GFI <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the I U.C. SWITCH — —I • • • • • I I d1 I I I <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing I FOR DISPOSAL K I T.I I1 I I I I <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />I I I I <br />18" for sinks and ranges installed in corner counters. I I I II I I <br />I II 0. I If 11 I I I <br />ELECTRICALi o z o 'L ` ENTRY <br />GFI <br />KEY 1 F III <br />H—� <br />DUPLEX CONVENIENCE OUTLET <br />I Ili -- � M II !)o <br />GFI@44" L — — — — — — — — — — — — I I <br />DUPLEX OUTLET ABOVE COUNTER PATIO I I d A.F.F. _ _ _ _ _ _ _ _ <br />wP WEATHERPROOF DUPLEX OUTLET CAFE G =J-' W 1 T - - - - - - - - <br />3 3 <br />'h DEDICATED RECEPTACLE <br />GFI GROUND FAULT INTERRUPTER DUPLEX OUTLET 1 � ____ I <br />FOR MICROWAVE RANGE \ I <br />HALF -SWITCHED DUPLEX OUTLET j \ HOOD PER SPECS N�1. ` _ FOYER <br />SPECIAL PURPOSE OUTLET °P _ WP I <br />WIDrn I , — GFI 48 I I <br />DUPLEX OUTLET IN FLOOR GFI I <br />220 VOLT OUTLET I G <br />�' WALL SWITCH — — — — — — — — — — — — — -------------- <br />j3 THREE-WAY SWITCH / / W. I C. <br />FOUR-WAY SWITCH / S. AHU I S.D. .D, <br />�4 � � I S. S. <br />$R RHEOSTAT SWITCH OWNER v7 RECEPT I BEDROOM 3 <br />CEILING MOUNTED LIGHT FIXTURE / SU ITFz / FOR I ROUGH -IN FOR <br />LED LED CEILING MOUNTED LIGHT FIXTURE / SYSTEM I OPT. CLG. FAN/ BEDROOM 2 <br />LIGHT PRE -WIRE <br />WALL MOUNTED LIGHT FIXTURE / '\\ 2 �' �� /%ROUGH -IN FOR <br />A,rL1/ \\ OPT. CLG. FAN/ <br />RECESSED LIGHT FIXTURE DISC. 4 I <br />ROUGH -IN FOR � � � \ LIGHT PRE-WIRI <br />O OPT. CLG. FAN! <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS WP I <br />+PC LIGHT PRE -WIRE <br />TRACK LIGHT GFI <br />FLUORESCENT LIGHT FIXTURE \ 0 \ ` <br />O EXHAUST FAN AC PAD �&Fl 6 VP <br />�QEXHAUST FAN/LIGHT COMBINATION <br />R. <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />H.B. <br />CH CHIMES (OPTIONAL) <br />PI3 PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CO CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />IM ELECTRIC METER <br />r_ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />��� <br />ROUGH -IN FOR OPT. CEILING FAN <br />� � <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />0 <br />0 <br />O <br />0 <br />N <br />0 <br />N <br />00 <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />v8 <br />Q <br />O O O ZT <br />r D N <br />V <br />M M n N <br /># pNp LL <br />Q <br />� <br />D J— <br />J * W <br />LL --Ia <br />N <br />a <br />ll Cc',, <br />�Nco <br />> �� <br />W ui <br />a(L <br />0 W o <br />Z_ <br />-00)'M <br />9 <br />a.:m O <br />W2 <br />J c ' <br />EE91a) <br />ca <br />LLZ <br />N rn<o <br />N0< <br />< O to <br />0o J <br />Z <br />d ❑0❑ <br />W <br />o <br />CDM� <br />N <br />z o <br />z o <br />—1 M <br />Gi N <br />N <br />M <br />0 <br />z 0 <br />U o <br />(3) <br />4t-J Cn Y <br />t V W O <br />Q <br />.O <br />V) <br />w � <br />c E <br />o <br />U m <br />w <br />t— m E <br />= O <br />ly <br />d <br />U O N <br />'I, to <br />¢ o <br />te, <br />.4 <br />o <br />W <br />CO <br />co <br />w2 <br />O s <br />Z <br />4�� <br />� <br />cxT E <br />E <br />wo <br />oo <br />>s <br />za <br />V <br />f-'- (6 <br />— <br /><Z <br />X OV <br />0�4 <br />, O <br />U <br />O <br />O <br />O E <br />N <br />n z <br />woo <br />a Z <br />'Z <br />d L <br />m <br />QZ <br />Y <br />U <br />mO <br />Z <br />Z <br />Zrn <br />J <br />b <br />Z Z <br />a <br />o< <br />go <br />INS <br />Hill <br />Q <br />Cj <br />¢ <br />90 <br />a <br />mw <br />k <br />a1 <br />r3 <br />o <br />Oa <br />w< <br />>O <br />a <br />za <br />�3 <br />0 C'7 <br />_ <br />> M <br />L <br />ai <br />c� <br />\ <br />,/ <br />L- <br />X <br />> <br />00%N <br />0 <br />Q <br />I1 <br />C 0 <br />2 <br />r <br />O O <br />� <br />N <br />T— <br />T <br />CDr <br />LO <br />..I.. I� <br />M N <br />O <br />s— <br />y <br />E <br />' LO <br />C T <br />M T <br />O <br />Z <br />cc <br />Z <br />E 10 <br />N <br />FL <br />U J <br />Q o <br />C <br />J <br />JOB <br />NO: <br />20-1785 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />