3059 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3059 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 12:34:25 PM
Creation date
2/28/2025 11:04:17 AM
Metadata
Fields
Template:
Building Plans
Street #
3059
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
133
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />\:TYP) SEE ELEV. <br />SIMPSON SP2 w/ (12) 10d <br />NAILS AT EACH STUD <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE STANDARD 3" DIA. TEE <br />SEE PLAN FOR HEADER SEE PLAN FOR SIZE THREADED 3" DIA. EXTENSION - <br />CONNECTION SCREW OFF CAP (3" DIA.)—� <br />DOUBLE 2x TOP <br />PLATE <br />2x DEAD WOOD @ MID FOR CLEAN -OUT <br />POINT w/ (3) 12d MIN. EXTENSION FROM <br />TONEAILS SPACED EXTERIOR FACE OF BLOCK <br />EVENLY „ <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />WALL IS 1 1/2 MAXIMUM INTERIOR <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL <br />FACE OF BLOCK WALL IS 21/4" <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />VARIES 2x BOTTOM PLATE W/ (1)10d @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL rT� <br />SCALE: N.T.S. S4 <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />(3)10d TOENAILS T&B <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />I STUD W/ (3) 10d NAILS <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 W/(10) 10d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90A HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />L-ROOFTRUSS <br />PLIFT CONNECTOR (SEE SCHEDULE) <br />OISTURE BARRIER <br />SCALE: N.T.S. <br />SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />CL <br />TO DRAIN <br />EXTERIOR <br />WALL <br />WALL CLEAN -OUT q <br />SCALE: N.T.S. SLI <br />1 ST COARSE 2ND COARSE 3RD COARSE <br />REFER TO WINDOW PRODUCT APPROVAL MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />SHEETS FOR INSTALLATION INFORMATION BY COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />MANUFACTURER. WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />TYPICAL SECTION THRU WINDOW g MASONRY LAYOUT D <br />S4 SCALE: N.T.S. S4 <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK WI (1) #5 FOR CONCRETE PLACEMENT <br />d <br />a <br />n <br />°0 <br />4 <br />4 a O d <br />u <br />8STD.90°HOOK 8" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />0 FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />t� SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4„ <br />FORM CONCRETE INSET TO <br />CREATE A SOLID BASE FOR <br />1/2"X9 1/2" PLYWOOD BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />J <br />J <br />Q <br />Ir <br />w <br />> <br />0 <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION <br />GARAGE ENTRY FORM DETAIL <br />2x6 MOUNTING BASE <br />SCALE: N.T.S. <br />�8x8x16 C.M.U. <br />GARAGE DOOR TRACK MOUNTING BRACKET <br />GARAGE DOOR ROLLER GARAGE DOOR TRACK <br />CONNECTION ASSEMBLY <br />GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />d <br />SCALE: N.T.S. <br />d 8 a a <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />T�� <br />S�Fp 0Ol'L <br />�N <br />2x CRIPPLES @ —� <br />16" O.C. W/ (2) 12d <br />TOENAILS T/B <br />SIMPSON SP4 wl (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" -- <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING <br />VERTICAL JAM <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />FOP <br />a <br />iARAGE <br />IOOR <br />vvvn r nn�.r� <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"xl0" OR <br />GREATER HEADER <br />1 <br />'—(2) 2x HEADER SEE PLAN <br />INTERIOR HEADER: <br />S4 <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER <br />• EXTERIOR HEADERS: <br />ONLY <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />' <br />2x STUDS TYP. <br />00 <br />OR <br />{ SIMPSON HTT4 TYP. <br />O,o <br />U.N.O. SEE N/S4 <br />HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL Q <br />SCALE: N.T.S. S4 <br />SIMPSON SIMPSON <br />SP4 SP2 <br />2X STUDS @ 24" O.C. <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />12 <br />(TYP.) SEE ELEV. <br />SIMIf'SON SP2 w/ (12)10d <br />NAIL AT EACH STUD <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. <br />926 APPLY 3 LAYERS W/ TOTAL <br />THICKNESS 7/8" OVER METAL <br />LATH. FIRST 2 LAYERS 3/8" THICK <br />EACH. 3RD LAYER 1/8" THICK. <br />CRICKET AS REQUIRED <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING (" <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />= <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEBEt <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />ROOF TRUSS <br />MOISTURE BARRIER <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL--- <br />W/ STD, 900 HOOK IN K.O. BLOCK _Mp�_ TYPICAL INTERIOR NON- <br />ALT. KNEEWALL ABOVE MASONRY WALL DETAIL E <br />S <br />SIMPSON SP4 <br />2X TOP PLATE r <br />OVERLAPPING / <br />TRUSS BOTTOM CHORD OR 2x4 <br />'BLOCKING W/ 2-16d TOE NAILS <br />@ EACH END <br />w <br />c� <br />2x TOP PLATE V <br />`n <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE EQUAL @ 12" O.C. <br />SEE A/S3 FOR STAGGERED FROM BOT. <br />REINF. INFO. PLATE TO CONCRETE <br />SCALE: N.T.S. <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE NAILS TOTAL) EA. SIDE OF <br />SPLICE STAGGERED <br />• M <br />• �4! <br />O/STD. �• • ' �10d @ 8" 0/C <br />ATTACH ALL J <br />EXTERIOR STUDS 4 W/ 16d TOENAILS <br />T076P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. �+ <br />F= 2240 LBS J�F <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />a <br />SIMPSON SIMPSON <br />SP4 —, SP2 -, <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />BEARING WOOD FRAME WALL <br />SCALE: N.T.S. S4 <br />,J <br />4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />° o ° • HTT4 w/ (18)10d NAILS (3610# SPF) <br />° o • HTTS w/ (26)10d NAILS (4670# SPF) <br />• DTT2Z w/ (8)1/4" x 1 1/2"SDS (1835#SPF) <br />o ° <br />° o • HDU2-SDS2.5 w/ (6)1/4" x 21/2"SDS (2215#SPF) <br />• HDU4-SDS2,5 wl (10)1/4" x 21/2"SDS (3285#SPF) HDU5-SDS2.5 w/ (14)1/4" x 21/2"SDS (4065#SPF) <br />• HDU8-SDS2.5 w/ (20)1/4" x 21/2"SDS (5665# SPF) <br />° <br />_ <br />• HDU11-SDS2.5 w/ (30)114" x 2112"SDS (6865#SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT w/ WASHER &NUT <br />9 • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT w/ WASHER & <br />• NUT <br />• FOR HDU8 USE 7/8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER &NUT <br />• FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER &NUT <br />° <br />HTT / HDU TENSION TIE rN <br />SCALE: NIT S4 <br />10d NAILS @ 6" <br />STAGGERED <br />SIMPSON <br />SP1 <br />SIMPSON- <br />J-BOLTS @ 24" O.C. <br />SP4 MAX <br />2X P.T. PLATE <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />o I I <br />d 2X8 P.T. BOTTOM P TE G' <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />" <br />a <br />a <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGERED <br />TRANSOM FRAMING <br />° ° BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES ° E SHEATHING <br />& 8" O/C FIELD S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY-5/8"X10" J-BOLTS @ 24" O.C. <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY rR� <br />SCALE: N.T.S. <br />G� <br />SCALE: N.T.S. <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE NAILS TOTAL) EA. SIDE OF <br />SPLICE STAGGERED <br />• M <br />• �4! <br />O/STD. �• • ' �10d @ 8" 0/C <br />ATTACH ALL J <br />EXTERIOR STUDS 4 W/ 16d TOENAILS <br />T076P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. �+ <br />F= 2240 LBS J�F <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />a <br />SIMPSON SIMPSON <br />SP4 —, SP2 -, <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />BEARING WOOD FRAME WALL <br />SCALE: N.T.S. S4 <br />,J <br />4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />° o ° • HTT4 w/ (18)10d NAILS (3610# SPF) <br />° o • HTTS w/ (26)10d NAILS (4670# SPF) <br />• DTT2Z w/ (8)1/4" x 1 1/2"SDS (1835#SPF) <br />o ° <br />° o • HDU2-SDS2.5 w/ (6)1/4" x 21/2"SDS (2215#SPF) <br />• HDU4-SDS2,5 wl (10)1/4" x 21/2"SDS (3285#SPF) HDU5-SDS2.5 w/ (14)1/4" x 21/2"SDS (4065#SPF) <br />• HDU8-SDS2.5 w/ (20)1/4" x 21/2"SDS (5665# SPF) <br />° <br />_ <br />• HDU11-SDS2.5 w/ (30)114" x 2112"SDS (6865#SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT w/ WASHER &NUT <br />9 • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT w/ WASHER & <br />• NUT <br />• FOR HDU8 USE 7/8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER &NUT <br />• FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER &NUT <br />° <br />HTT / HDU TENSION TIE rN <br />SCALE: NIT S4 <br />10d NAILS @ 6" <br />STAGGERED <br />SIMPSON <br />SP1 <br />SIMPSON- <br />J-BOLTS @ 24" O.C. <br />SP4 MAX <br />2X P.T. PLATE <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />o I I <br />d 2X8 P.T. BOTTOM P TE G' <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />" <br />a <br />a <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGERED <br />TRANSOM FRAMING <br />° ° BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES ° E SHEATHING <br />& 8" O/C FIELD S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY-5/8"X10" J-BOLTS @ 24" O.C. <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY rR� <br />SCALE: N.T.S. <br />G� <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />o I I <br />d 2X8 P.T. BOTTOM P TE G' <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />" <br />a <br />a <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGERED <br />TRANSOM FRAMING <br />° ° BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES ° E SHEATHING <br />& 8" O/C FIELD S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY-5/8"X10" J-BOLTS @ 24" O.C. <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY rR� <br />SCALE: N.T.S. <br />G� <br />o <br />— <br />Q <br />i <br />�J <br />" ,,,••F 1.0 •• <br />2 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer s signature and seal. <br />0) <br />cc t- <br />N CO Tt <br />O O O tm co N <br />V <br />Lo <br />J M N (V c u7 N Il. <br />N # m <br />to <br />ro <br />7 J u- a- <br />LL LL <br />Q <br />N <br />' M W y <br />ai i� a Wa <br />z <br />0 <br />(L <br />>L <br />Wo <br />i <br />a o C)m- <br />w <br />2 EC � o <br />N <br />us 3 <br />-@ N O <br />N<CMZ U J <br />z <br />° ❑❑❑ <br />W <br />M e- <br />M <br />z N O <br />0 0 <br />Z N <br />o� <br />z <br />J M <br />d N <br />c� <br />M <br />0 <br />0 <br />T <br />Cn Y <br />o a <br />G)0we <br />c/) <br />V) <br />c E <br />�.. <br />� <br />� o <br />U m <br />Rig <br />r— m <br />O <br />I� •.. <br />= N <br />lo Y <br />o <br />0 <br />co <br />o <br />W <br />Z <br />wz <br />�o <br />QE�o <br />ca <br />_® <br />O <br />-o <br />o< <br />S 8 <br />dz <br />CV <br />a? L <br />Wz <br />p <br />¢ o <br />J <br />m g <br />no <br />� <br />-ai <br />z <br />Y <br />m''<W <br />a <br />Z <br />N <br />a 3 <br />�w <br />8� <br />Qo <br />a" <br />�w <br />LU <br />v 3 <br />� <br />az <br />3 <br />o <br />m <br />�O <br />ct <br />°z ¢ <br />am <br />ou <br />c <br />�N <br />= <br />` <br />> d' <br />J <br />ai <br />W <br />� <br />c� <br />.! <br />Ln <br />LO <br />^ <br />CU <br />T <br />O <br />CD <br />/I1 m <br />c <br />T <br />0) <br />■ <br />T <br />J *— <br />T <br />2 I.i) <br />LO <br />T <br />M <br />o <br />(a <br />Z <br />T <br />E O <br />ii CV <br />y r <br />Z <br />cc <br />c <br />a <br />v <br />Q O <br />= <br />JOB <br />NO : <br />20-1783 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S4 <br />