My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3059 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3059 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 12:34:25 PM
Creation date
2/28/2025 11:04:17 AM
Metadata
Fields
Template:
Building Plans
Street #
3059
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
133
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY7 <br />BON <br />TERMINATIOP <br />NEC 14, 250.94J <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />upper to lights & outlets <br />opperto 20 amp ckts <br />copper to WH <br />copper to Dryer <br />2 Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />(Votes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />� WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUSTFAN <br />v <br />,Or <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FCHI <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />f [ <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />Vlf <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />�1111111■1111�11���■111111111111�1■1■11�1����1�'11��111■11111� <br />� D ■n�■�Til�i�■�� <br />... F,0� r•�l�1�om©` <br />ow <br />Ell <br />Grr— <br />C.M <br />D R•• <br />ON •- <br />•-IGHT PRE -WI RE�;A <br />U.C. OUTLET <br />`— U.C. OUTLET <br />ROUGH -IN FOR FOR DW <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />FAMILY RM <br />)D <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />\ LIGHT PRE -WIRE \ <br />OWNER'S SUITE <br />I <br />a <br />GFI <br />�I <br />- - - - - - - - - - <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />��{{ I <br />�lW .C. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />----- -----J <br />RECEPT. <br />FOR ALARM <br />SYSTEM — <br />ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />/ 12 <br />BED�606, <br />� 1 <br />\ �///(S <br />GFI @ 44" <br />A.F.F. <br />R <br />- _---- <br />II <br />I `mil l <br />I 11 I <br />L_ _r_ <br />I I <br />I <br />:GFI @ 44" � I <br />A.F.F. <br />I <br />GFI FOR <br />GAR. DOOM <br />GFI <br />2 CAR GARAGE <br />I <br />O I <br />W.H. VERIFY LOCATION <br />IRRIGATION <br />_ ELECTRICAL PANEL <br />�_, GFI @ 4,P A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />/ ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />G LIGHT PRE -WIRE <br />BEDR <br />OOM M 4 <br />� . <br />GFI <br />ENTRY <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />fjJ(/I <br />l <br />a <br />-i1 <br />r/ <br />r— <br />ICI <br />O <br />- <br />�vLl <br />roE <br />l <br />0 <br />N <br />0 <br />N <br />1 <br />CO <br />0 <br />To the best of the Engineer's knowledge information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />MW as <br />a <br />Co <br />98 N o7 ap <br />o V <br />O O O LA <br /><O N # <br />o <br />M N N C <br />M M <br /># &co LL <br /># <br />H <br />7 U_ N <br />J W <br />LL LL a. <br />N <br />a <br />� yM <br />ai m t:� <br />w vi <br />M a it <br />��� <br />0 o <br />Z <br />2a <br />W <br />ADO <br />[� CODJ <br />Z <br />LL <br />rn< N O< <br />NMZ <br />N <br />U0 <br />0 <br />�J <br />Uj <br />z N O <br />o a <br />m� <br />z N <br />z " � <br />a o <br />d N <br />Wil <br />M <br />Z <br />U o <br />Q) <br />_ <br />C!) y <br />L.0 <br />o a <br />�U Q <br />0 <br />c o <br />o <br />�.. <br />� <br />� <br />U CO <br />w <br />o i....., <br />1- E <br />N <br />_ O U <br />zi1 <br />U o' N <br />° <br />c � <br />_ Q <br />o <br />co <br />w <br />M <br />M <br />n¢ <br />o <br />z <br />z <br />_ _ <br />� <br />Q E <br />0cc <br />I <br />mo <br />z <br />0 o <br />Z) o <br />z <br />K00 <br />U <br />aQ <br />0OU <br />0 Z <br />O E <br />O <br />--a) to <br />i <br />W 0Z <br />¢ <br />az <br />j <br />to <br />(n <br />❑ <br />Z2 <br />O y <br />U <br />m 0 <br />o <br />oLL <br />Z' <br />J <br />m <br />a <br />Q W <br />Z z <br />rn <br />3 <br />oa <br />go <br />;2 <br />LLLL <br />a <br />�W <br />C) <br />5 Wr <br />o <br />;o <br />E <br />v <br />.< <br />°3 <br />0 CV <br />= <br />` <br />>� <br />J <br />L <br />rn <br />� <br />Al <br />W <br />� <br />.� <br />L0 <br />T <br />0 <br />O <br />0 <br />2 <br />T <br />O <br />0+ <br />{ O7 <br />rrt• <br />J T <br />O <br />,�^ <br />r <br />T L.n <br />o � <br />r <br />LO <br />ai <br />m <br />T <br />3 <br />M r <br />o <br />Z <br />E O <br />r <br />t6 <br />d <br />E <br />U <br />Q p <br />JOB <br />NO: <br />20-1783 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />