0 <br />LZ <br />N <br />N <br />N <br />:3 <br />O <br />d <br />O <br />CV <br />O <br />ci <br />S <br />w <br />0 <br />cn <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to 111111s 1, outlets <br />00 A MP 200 A1 #12 copper to 20 amp clas <br />#10-2 copper to WH <br />#10-3 copper [o Dryer <br />METERMAIN <br />II <br />0 or 410 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED- j <br />INTERSYSTEM lull�#4GROUNDING <br />4 Bare Cu Ground <br />BONDING O <br />WIRE <br />TERMINATION PER jI <br />WITH CODE APPROVED <br />NEC 14, 250.94 J <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />� wP <br />WEATHERPROOF DUPLEX OUTLET <br />�&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I Ph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;O <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH 1 <br />CHIMES (OPTIONAL) <br />FE9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />_Mai <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />ELECTRICAL PLAN — ELEV—Al <br />SCALE: %4"=V-0" <br />0 <br />N <br />O <br />N <br />N <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />.. .. W <br />E <br />�p <br />oo <br />Q <br />0 <br />O O <br />r- 00 <br />N fi� <br />CD <br />N i* ik <br />LQJ <br />CV N <br />N lL LJL- <br />� <br />C <br />0 <br />O) 'NO <br />�_j <br />J ik W W <br />LL LL a <br />Q <br />252 <br />c) z <br />N'6a <br />> <br />a W W 0 <br />. <br />13Z <br />�(� <br />0Cr <br />O <br />1% <br />W <br />= C CV <br />'more <br />m m O <br />�¢o <br />W <br />Z <br />IL <br />2 E T <br />~ N 0 <br />a M Z <br />X o a <br />Q O <br />N <br />U I_J <br />Z <br />°° <br />F 7 r I <br />W <br />z N (D <br />ono <br />z N <br />z C, � <br />z <br />VJ <br />� <br />4-d <br />U <br />Y <br />o <br />0 <br />to <br />C <br />V) <br />_o <br />U CD <br />T E <br />o g <br />I <br />�Q <br />• <br />01 o <br />SI <br />CDw <br />CID <br />M <br />y Z <br />o L <br />z <br />1 <br />LL <br />=� <br />� <br />>R <br />Z" <br />14� <br />E <br />'° <br />z <br />oa <br />F� @ <br />x� <br />ao0a <br />00 <br />Z— <br />o <br />N <br />ww <br />d <br />w0 <br />o <br /><o <br />ms <br />���oZ <br />C <br />U <br />Z <br />Z <br />.__I <br />m <br />a a° <br />Q W <br />I Z <br />rn <br />N <br />o. <br />o <br />500 <br />W <br />�p <br />> 0 <br />o- <br />tD <br />W¢ <br />z< <br />a F <br />Ova <br />2C <br />a <br />= <br />>M <br />ai <br />W <br />m <br />0 <br />•>y <br />Ln <br />M <br />M <br />.-. <br />CID <br />2 <br />O N <br />0) <br />T <br />LO <br />>. N <br />T <br />r <br />.= Lo <br />r <br />T <br />0 <br />O <br />ai <br />E <br />w <br />c co <br />M <br />o <br />z <br />ca <br />Z <br />E O <br />N <br />cccc <br />U <br />d <br />p <br />C <br />d <br />_5 <br />Q <br />JOB <br />NO: <br />20-1131 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />