Laserfiche WebLink
1090 <br />8F8-1 B/1 T <br />GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed L/360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load < 1 •0 <br />Safe vertical load Safe horizontal load - <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />WPM =wpm= <br />8F44 1B/1T8F40 1B/1T 8RF400B/1T 8F321B/1T <br />FORM do GROUT SOLID <br />CV Q <br />9 W <br />01 r U <br />/5 BAR CONT. <br />8F12-1B/1T <br />O <br />V' LINTEL DETAIL <br />SCALE = N.T.S. <br />-now <br />F = FILLED WITH <br />GROUT / <br />U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />J <br />8F 16- <br />B/1 T <br />H <br />a <br />tNOMINAL, <br />L QUANTITY OF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />MATERIALS <br />cTi precasirntels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 318" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5 REBAR <br />MIN. <br />(1) REQ'D <br />CLEAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />° <br />A 0 a <br />#5 REBAR AT TOP <br />° <br />.M.U. <br />w <br />a° A <br />MIN.(1)REQ'D Q <br />1-112"CLEAR <br />S <br />a <br />z <br />° <br />, J <br />° <br />z <br />GROUT <br />D <br />< <br />�o <i ° <br />rn H cr ° Q <br />C.M.U. <br />5 REBAR AT <br /><n <br />= U) U)w <br />BOTTOM OF <br />r- N z w _ <br />m 4 <br />o <br />LINTEL CAVITY <br />o 0 W 1 <br />Lou <br />-BOTTOM <br />0 U O- L <br />REINFORCING <br />Q a t7 mIt: g > > <br />LL <br />- <br />7-5/8"ACTUAL <br />PROVIDED IN <br />Z p w n D l D <br />8" NOMINAL WIDTH <br />LINTEL <br />O 3 � <br />�, <br />#5 REBAR AT BOTTO <br />INDICATED <br />(VARIES) <br />c~n rn Ir a. Go �o <br />AS <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />UF <br />4'-0" LL <br />6-10" LL <br />LINTEL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />�Frrle. <br />V, ; t� <br />1. v. <br />r� <br />�..° <br />Si <br />. <br />+ <br />•••......... �3 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />(• <br />Q <br />��QQ <br />� E OD_ N tG pp <br />N i! <br />0 0 0 m f0 <br />N � N * 0,4LL LL <br />9) <br />:1 LL LL <br />f» <br />Q <br />cN <br />N , W h <br />alma as 'mo <br />Z <br />.0U)°' 0IXo <br />C 9 <br />m Q <br />C m O <br />W <br />LL W <br />mo�CO ¢u0 <br />E4' <br />�0'5 <br />Z <br />NaMZ <br />z <br />U I- <br />° L) ❑❑a❑ <br />_ W <br />p� <br />Z N O <br />v <br />Q <br />n <br />M <br />c/1 <br />z <br />C� LL <br />a--� <br />cn <br />LU <br />o <br />U <br />¢ <br />Tt+-• <br />0 <br />N <br />w <br />C <br />Z:) � <br />'1 <br />� o <br />U 0° <br />w <br />E <br />E <br />g <br />0 <br />• <br />U 'o <br />Q o <br />m <br />S <br />m <br />o <br />Mh< <br />J <br />w <br />Z <br />M <br />0 <br />Q <br />� <br />Q E <br />zo <br />oo <br />wj <br />yR <br />ZR <br />oa <br />U '6 <br />cc <br />cc c <br />O <br />0 <br />§ <br />a <br />K <br />UO <br />�� <br />Z <br />ro <br />Nro <br />°z <br />�o <br />a z <br />ttw <br />ro <br />dro <br />Cy <br /><i <br />mO <br />oz <br />z r <br />z <br />v <br />J <br />m <br />7 y <br />¢w <br />20 <br />O <br />1 <br />g� <br />LL <br />O <br />Z' a <br />Sw <br />W <br />Va <br />~r <br />yZ <br />W <br />=3 <br />U H <br />o <br />t0 <br />w< <br />O <br />a <br />03 <br />� <br />z< <br />.0M <br />� <br />>M <br />L <br />CI' <br />c� <br />,!LO <br />N <br />� <br />T <br />C� <br />o <br />O <br />Co <br />= <br />O N <br />T <br />O <br />LO <br />u- <br />J N <br />n <br />T <br />Ln <br />r <br />N <br />000 r <br />r <br />ai <br />I.f) <br />o <br />M <br />o <br />E <br />Z <br />c <br />E O <br />`° <br />a <br />E <br />U 0 <br />Q p <br />c <br />JOB <br />NO: <br />20-1126 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />