My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3092 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3092 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 1:01:12 PM
Creation date
2/28/2025 11:04:47 AM
Metadata
Fields
Template:
Building Plans
Street #
3092
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
22787
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp tits <br />#10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O2/0 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING o #4 GROUNDING WIRE <br />TERMINATION PER 7{ WITH CODE APPROVED <br />NEC 14, 250.94 J CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at42" centerline above finished floor. <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />I <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />I <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />I <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />I <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />I <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />I <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />I <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />I <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />I <br />I <br />I <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />I <br />WEATHERPROOF DUPLEX OUTLET <br />WP <br />I <br />IGFI GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />I <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />SPECIAL PURPOSE OUTLET <br />I <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />I <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />I <br />& . FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />j <br />CEILING MOUNTED LIGHT FIXTURE <br />j <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />I <br />WALL MOUNTED LIGHT FIXTURE <br />I <br />RECESSED LIGHT FIXTURE <br />I <br />I <br />Pc LIGHT FIXTURE WITH PULL CHAIN iN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />I <br />EXHAUST FAN <br />1 <br />I <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />�D PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CO CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />o_ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />r�ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G ' J OPT. CEILING FAN <br />GID (1) PHONE LINE, (1) DATA PORT <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />UPPER FLOOR ELECTRICAL PLANT <br />SCALE: %4'=1'-0" <br />f, <br />rt <br />K <br />#"; <br />k <br />I <br />xr <br />'v <br />f <br />r 7 <br />'4 <br />it <br />0 <br />0 <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building <br />Code - <br />Residential 6th Edition. Engineer's <br />signature and seal Is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal <br />W <br />Q <br />E <br />a CO$ <br />98 co <br />ouco <br />MN N <br />N <br />u- LL <br />® <br />N M W N <br />a <br />J UOD w <br />d <br />H <br />� � <br />IL � 0- <br />vi <br />'6 <br />�mLL <br />w = <br />as WY <br />13Z <br />13 <br />-00rn <br />Z 0 <br />W <br />mw)0 <br />oonr° <br />W O o <br />o <br />Coc_50 <br />W <br />Earn <br />o a g <br />NQc)ZLL <br />W <br />N O <br />0 0 <br />z <br />� N <br />^^N'' <br />M <br />W <br />2 <br />o <br />-J <br />C/ LL <br />ru <br />LU Y <br />o <br />O— <br />v . o <br />E <br />I <br />{13 <br />Nook <br />' - <br />� -m <br />W m <br />WIN <br />o g <br />0 <br />¢ 8to <br />co <br />w <br />M <br />o <br />z <br />Z <br />o <br />} N <br />c%. o <br />w <br />oa <br />t - <br />U <br />U <br />n <br />N170 <br />a� <br />�o <br />O� <br />ww <br />Y, <br />i <br />M <br />me <br />ao <br />0�o' <br />m� <br />O <br />z <br />W J <br />¢ s <br />! z <br />rq <br />N_ <br />H w <br />2 <br />Z <br />5Z <br />a <br />son Von <br />Q y <br />w <br />NH <br />�j <br />O <br />aF <br />a0 <br />GO <br />a <br />M <br />—� <br />ai <br />m <br />nn11 <br />W <br />m <br />0 <br />.= <br />M <br />X <br />> <br />O <br />Q <br />C o <br />a <br />•L� <br />� <br />n 1 m <br />= <br />r <br />� <br />O <br />*� <br />.r <br />OO <br />J N <br />T— <br />O <br />tV <br />= C.0 <br />rn N <br />,— <br />T <br />a) <br />,T <br />� M <br />� ` <br />N <br />o <br />z <br />m <br />z <br />E <br />av <br />E <br />°, <br />a <br />Q <br />JOB <br />NO: <br />20-1132 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />